Pilz 777306 PNOZ X2.7P Safety Relay 24-240 V AC/DC in Madurai
Order the Pilz 777306 PNOZ X2.7P from Indus MegaMart for machine-control and maintenance requirements in Madurai. This standalone safety relay combines a 24–240 V AC/DC supply with three normally-open safety contacts, one normally-closed auxiliary contact and plug-in screw terminals. It is intended for emergency-stop and safety-gate monitoring in an appropriately designed safety circuit. Its narrow 22.5 mm housing is useful when replacing an existing relay in a compact control cabinet.
Before placing your order, match part number 777306 to the installed relay or approved bill of materials. Confirm the current price, GST basis, selling unit and required quantity on the product listing; check delivery serviceability for your Madurai pincode. Generated purchase invoices include Indus MegaMart’s GST number.
Buy now – Pilz PNOZ X2.7P 777306
Technical specifications
|
Parameter |
Specification |
|
Manufacturer/model |
Pilz / PNOZ X2.7P, 777306 |
|
GTIN |
4046548009842 |
|
Supply/frequency |
24–240 V AC/DC; 50–60 Hz on AC |
|
Power consumption |
4.5 VA AC / 2 W DC |
|
Inputs/start |
Two inputs; single- or dual-channel configurations; monitored start |
|
Relay contacts |
3 instantaneous NO safety contacts; 1 instantaneous NC auxiliary |
|
Semiconductor outputs |
None |
|
Safety contact ratings |
AC-1: 6 A at 240 V AC; DC-1: 6 A at 24 V DC; AC-15: 3 A at 230 V AC; DC-13: 4 A at 24 V DC (6 cycles/min) |
|
Multi-contact loading |
4.5 A per contact when three safety contacts are loaded, under the AC-1/DC-1 thermal-current conditions in the manual |
|
Connection |
Plug-in screw terminals; 24–12 AWG flexible conductor range |
|
Dimensions (H × W × D) |
94 × 22.5 × 121 mm |
|
Housing / ambient |
IP40; −10 to +55 °C; no condensation |
|
Net weight |
200 g |
|
OEM packaging |
1 relay per manufacturer packaging unit |
Selecting the correct relay for your control panel
The wide-range supply is a key reason to select 777306 rather than the 24 V AC/DC version, 777305. If your wiring requires spring-loaded connectors, 787306 is the corresponding wide-range terminal variant. Do not treat these variants as automatic drop-in replacements: check the circuit, terminal connections, load characteristics and safety requirements against the manufacturer’s manual.
For an emergency-stop station or interlocked guard, the relay can monitor suitable single- or dual-channel inputs, depending on the approved circuit. Monitored start supports control of the restart sequence; the three safety contacts switch the safety circuit, while the NC auxiliary contact provides status signalling. The relay is a component of the machine safety function, not proof that the complete machine complies with a required safety level.
The 6 A figure is not a universal switching limit. Check the utilisation category, number of loaded contacts, fusing and switching duty before selection. E-stop response time and supply-loss response time differ; use the exact values and circuit restrictions in the operating manual. The IP40 housing requires appropriate enclosure protection. Keep direct light-curtain/OSSD connection outside the assumed application for this wide-supply variant. Installation and validation must be performed by qualified personnel.
Ordering and delivery for Madurai
Orders and payments are accepted even if your requested quantity exceeds available stock or the stock count is zero. Indus MegaMart’s delivery policy is within 7 days when the ordered quantity is within available stock, and within 7–14 days when it exceeds available stock, including zero stock. Confirm serviceability for the destination pincode and review the listing for selling unit, warranty and return conditions before payment.
Explore other Pilz products
Compare safety relays
Frequently asked questions
1. Can I use 777306 on a 230 V AC control supply?
Yes. Its nominal supply range is 24–240 V AC/DC. Check the actual supply and installation requirements in the Pilz operating manual before commissioning.
2. Is the NC contact a fourth safety output?
No. The three NO contacts are instantaneous safety outputs. The NC contact is an auxiliary contact for signalling; it must not be used as an additional safety output.
3. Can 777306 replace 777305 or 787306?
Do not substitute on the model name alone. 777305 is the 24 V AC/DC screw-terminal model, while 787306 uses spring-loaded terminals with the wide-range supply. Confirm circuit compatibility and safety validation before any change.
4. Can I connect a light curtain directly to this relay?
Do not assume direct OSSD compatibility. The manual’s ESPE input example is restricted to 777305 and 787305 at 24 V DC. Have a qualified engineer select the correct interface for your light curtain.
5. Is 777306 rated 6 A for all loads?
No. The 6 A rating applies to AC-1/DC-1 at the specified contact voltages. AC-15 is 3 A at 230 V AC; DC-13 is 4 A at 24 V DC at six cycles per minute. Check multi-contact loading and protective-device requirements as well.
6. How many relays are in a pack?
Pilz specifies one relay per manufacturer packaging unit. Check the selling unit and quantity on the product listing before ordering; manufacturer packaging does not establish the merchant’s sale unit.
7. Can I order more relays than the available stock for Madurai?
Yes. Indus MegaMart accepts orders and payments for quantities exceeding stock, including zero-stock items. Delivery is within 7 days for quantities within available stock and within 7–14 days for quantities above stock. Confirm serviceability for the delivery pincode.
Buy Pilz 777306 PNOZ X2.7P safety relay – check current price and order