Order the Fluke 15B MAX Digital Multimeter with TL31 Test Leads – Kit 02 from Indus MegaMart for electrical maintenance, electronics servicing and industrial troubleshooting in Vijayawada. The 15B MAX-02 configuration pairs the 6000-count voltage display with extra-slim TL31 probes for access to small components and closely spaced test points. It measures AC and DC voltage and current, resistance, capacitance, diodes and continuity. The meter is rated CAT III 600 V, with an Input Alert that warns of certain incorrect lead connections.
Check the current price and GST breakdown on the product listing, select your required quantity and verify delivery for your Vijayawada pincode. If you need both standard and fine-tip leads, choose the separate dual-lead version rather than assuming both are included in Kit 02.
View price and buy Fluke 15B MAX Kit 02
What comes with the 15B MAX-02?
Fluke specifies the following manufacturer configuration: one 15B MAX digital multimeter, one TL31 extra-slim test lead set with two protective caps, two AA batteries and safety information. Confirm the actual selling pack and any additional accessories on your order; a carrying case, TL75 leads, thermocouple or calibration certificate is not part of the stated standard configuration.
Why choose TL31 leads and Input Alert?
Fine probe tips are particularly useful for service benches, crowded printed circuit boards and small terminals where ordinary probes may be difficult to position. The lead caps must be correctly fitted for CAT III work. Fine tips do not increase the meter’s safety category or make energized circuits safe to touch.
The meter gives audible and flashing visual warnings if a lead remains in a current terminal while a voltage, resistance, capacitance, diode or continuity function is selected. Input Alert is a reminder, not a substitute for checking terminals and circuit conditions. Auto ranging, manual range selection, display Hold, backlight and wake-up by pressing a button make routine measurement work more convenient.
Fluke 15B MAX-02 technical specifications
|
Measurement |
Ranges |
Resolution |
Accuracy (±) |
|
AC voltage (40–500 Hz) |
6.000 / 60.00 / 600.0 / 1000 V |
1 mV / 10 mV / 0.1 V / 1 V |
1.0% + 3 |
|
DC voltage |
6.000 / 60.00 / 600.0 / 1000 V |
1 mV / 10 mV / 0.1 V / 1 V |
0.5% + 3 |
|
AC / DC millivolts |
600.0 mV |
0.1 mV |
AC 3.0% + 3; DC 1.0% + 10 |
|
AC / DC microamps |
400.0 / 4000 µA |
0.1 / 1 µA |
1.5% + 3 |
|
AC / DC milliamps |
40.00 / 400.0 mA |
0.01 / 0.1 mA |
1.5% + 3 |
|
AC / DC amps |
4.000 / 10.00 A |
0.001 / 0.01 A |
1.5% + 3 |
|
Resistance |
400 Ω; 4 / 40 / 400 kΩ; 4 / 40 MΩ |
0.1 Ω; 1 / 10 / 100 Ω; 1 / 10 kΩ |
400 Ω: 0.5% + 3; middle ranges: 0.5% + 2; 40 MΩ: 1.5% + 3 |
|
Capacitance |
40 / 400 nF; 4 / 40 / 400 / 2000 µF |
0.01 / 0.1 nF; 0.001 / 0.01 / 0.1 / 1 µF |
nF: 2% + 5; µF: 5% + 5 |
|
Diode test |
2.000 V |
0.001 V |
10% |
|
Continuity |
Beeper below 70 Ω |
— |
— |
Accuracy is expressed as percentage of reading plus least-significant digits, specified for one year after calibration at 18–28 °C and 0–75% RH. AC current is specified at 40–400 Hz; AC inputs below 1% of range are not specified. Capacitance accuracy excludes lead capacitance and instrument floor (up to 1.5 nF on the 40 nF range).
| General parameter |
Specification |
|
Display |
6000 counts; 3 updates/s; backlight; auto/manual ranging and Hold |
|
Input limits |
1000 V differential V–COM; 600 V maximum terminal-to-earth |
|
Measurement category |
CAT III 600 V; pollution degree 2 |
|
Current fuses |
0.44 A / 1000 V and 11 A / 1000 V; specified fast-blow replacements only |
|
Power |
Two AA (IEC LR6); minimum 500 h nominal battery life |
|
Meter dimensions / weight |
183 × 91 × 49.5 mm; 455 g |
|
Environment |
IP40; operation 0–40 °C, up to 2000 m; storage −30 to 60 °C |
|
EMC |
CISPR 11 Group 1 Class A; not intended for residential environments |
Safety and operating limits
The 1000 V voltage range refers to differential voltage across the V and COM terminals; each terminal must remain within 600 V of earth. The meter’s CAT III 600 V rating is not CAT III 1000 V or CAT IV. Use the lowest rating of the meter, probes and accessories. Fit the protective caps for CAT III, inspect lead insulation and keep fingers behind probe guards. Qualified personnel must follow the Fluke manual and applicable electrical safety procedures.
The 10 A range is limited to less than 7 minutes on, followed by 20 minutes off. Current measurements require the proper fused current input and a series connection to a de-energized circuit before testing; never place a current-input connection across a voltage source. Disconnect power and discharge capacitors before resistance, continuity, diode and capacitance tests. IP40 is not a water-resistant rating. This Class A instrument is not intended for residential environments.
Where Kit 02 fits in maintenance and electronics work
Electrical maintenance teams can use it for supply-voltage checks, control wiring and isolated component tests within its ratings. Electronics repair and development teams benefit from fine-tip access for checking small resistors, diodes and capacitors. Facility and HVAC technicians can check electrical supplies and continuity, but the instrument does not measure temperature. For UPS and DC control circuits, confirm the voltage to earth and measurement category before use. It is not an insulation-resistance tester, earth-resistance tester or logging meter.
Choose the right Fluke 15B MAX configuration
|
Configuration |
Manufacturer lead set |
Best fit |
|
15B MAX-01 / Kit 01 |
TL75 |
General contact measurements |
|
15B MAX-02 / Kit 02 |
TL31 |
Fine-tip access to small test points |
|
15B MAX KIT |
TL75 + TL31 |
Both probe styles required |
The 15B MAX meter functions are shared across these three configurations; the lead selection changes. If frequency, duty cycle or temperature measurement is essential, consider the 17B MAX instead. If work involves distorted AC waveforms, select a meter explicitly specified as True RMS rather than assuming the 15B MAX has that capability.
Explore other digital multimeters
Browse Fluke instruments
Buy Kit 02 for Vijayawada delivery and bulk procurement
Indus MegaMart supports industrial and commercial procurement in Vijayawada NCR. Check the price including GST, actual selling quantity and pincode on the Kit 02 listing. Under the standard order policy, purchases within available stock are delivered within 7 days; orders exceeding available stock, including zero-stock orders, can still be placed and paid for with a 7–14 day delivery timeline. Confirm the delivery details for your pincode and required quantity before ordering.
For repeat orders or project requirements, specify the 15B MAX-02 with TL31 leads so the procurement team does not substitute a different kit. Confirm warranty eligibility, calibration paperwork if required, and return terms before purchase.
Frequently asked questions
1. Does Kit 02 include TL75 leads as well?
No. The OEM 15B MAX-02 configuration contains the TL31 fine-tip set with two caps, two AA batteries and safety information. Choose the separate 15B MAX KIT if both TL75 and TL31 sets are required.
2. Can I use the TL31 leads in CAT III panels?
Yes, within the meter’s CAT III 600 V rating and the ratings of the leads and accessories, with the protective caps correctly fitted. Never use uncapped tips for CAT III work.
3. Can the 15B MAX measure frequency, duty cycle or temperature?
No. Those functions belong to the 17B MAX. The 15B MAX supports voltage, current, resistance, capacitance, diode and continuity measurements; True RMS is not specified by Fluke for this model.
4. Can the TL31 leads be replaced?
Yes. The Fluke manual lists TL31 replacement sets as part numbers 5343862 or 5595980. Confirm the approved replacement and its ratings before ordering.
5. Can this kit test capacitors on a circuit board?
It measures capacitance up to 2000 µF. Disconnect power and discharge capacitors first; parallel circuit paths and lead capacitance can affect the reading, so isolate the component when necessary.
6. Is the 10 A range suitable for continuous motor-current testing?
No. At 10 A, Fluke specifies less than seven minutes of measurement followed by 20 minutes off. Use an appropriately rated clamp meter for higher currents or where the circuit cannot be opened safely.
7. Can a Vijayawada business buy several kits with a GST invoice?
Yes. Indus MegaMart accepts orders for the required quantity and issues purchase invoices containing its GST number. Confirm the complete selling pack, applicable warranty and any calibration certificate requirement before placing a procurement order.
8. How do I check delivery to my Vijayawada address?
Open the exact Kit 02 product listing, enter the delivery pincode and check the available delivery details for your quantity. Orders and payments are accepted even when stock is insufficient or zero; the standard delivery policy is 7–14 days in that case.
Buy Fluke 15B MAX Digital Multimeter with TL31 Test Leads – Kit 02