Fluke 28 II Digital Multimeter in Ulhasnagar
For industrial maintenance teams that move between switchrooms, plant equipment and outdoor service sites, the Fluke 28 II is a rugged True RMS digital multimeter designed for demanding field conditions. The standard model, OEM part 3301271, combines IP67 enclosure protection, AC/DC measurement up to 1000 V, a low-pass filter for variable-speed drive diagnostics and Type-K temperature measurement. It is not the intrinsically safe 28 II Ex variant.
Ordering for Ulhasnagar? Review the current price including GST, select the exact model and check your required quantity and delivery pincode on the product listing. Confirm the sale unit and accessory contents before completing the purchase.
Buy Now — Fluke 28 II Digital Multimeter
Rugged field use without compromising electrical safety
The 28 II is designed to resist ingress of dust and water under its IP67 rating and has been tested for a 3-metre drop with its holster fitted. Backlit keys and the display make the instrument easier to read in poorly lit plant rooms. This combination is useful for service engineers maintaining equipment where handling and environmental protection matter as much as measurement range.
IP67 is an enclosure rating, not permission to work on wet live conductors or in explosive atmospheres. Fluke’s safety instructions say not to use the instrument around explosive gas or vapor or in damp or wet environments. Use only within the correct measurement category, with the lowest-rated component in the measurement assembly determining the applicable limit. Qualified personnel should follow site safety procedures and the manufacturer's instructions.
Fluke 28 II technical specifications
|
Parameter |
Specification |
|
Model / MPN |
Fluke 28 II / 3301271 |
|
Display |
6000 counts; 19,999-count high-resolution mode; backlight and bar graph |
|
Voltage AC/DC |
0.1 mV to 1000 V; True RMS AC |
|
Basic DC voltage accuracy |
±(0.05% of reading + 1 count), specified conditions |
|
Basic AC voltage accuracy |
±(0.7% + 4 counts), range and frequency dependent |
|
Current AC/DC |
0.1 µA to 10 A; AC True RMS; see duty-cycle limits |
|
Basic AC / DC current accuracy |
AC ±(1.0% + 2 counts); DC ±(0.2% + 4 counts); conditions apply |
|
Resistance |
0.1 Ω to 50 MΩ |
|
Capacitance |
1 nF to 9999 µF (manufacturer summary) |
|
Frequency counter |
0.5 Hz to 199.99 kHz; sensitivity depends on input |
|
AC voltage bandwidth |
15 Hz to 20 kHz on specified ranges |
|
Temperature input |
−200 to +1090 °C; supplied 80BK-A probe −40 to +260 °C |
|
Other functions |
Continuity, diode test, duty cycle, relative mode, auto/manual ranging, AutoHOLD |
|
Capture modes |
Min/Max/Avg; peak capture response 250 µs |
|
Electrical safety |
CAT III 1000 V / CAT IV 600 V; maximum 1000 V to earth |
|
Housing protection |
IP67; 3-metre drop test with holster |
|
Operating environment |
−15 to +55 °C; −40 °C for up to 20 minutes when taken from 20 °C; up to 2,000 m altitude |
|
Relative humidity |
0–95% at 0–35 °C; 0–70% at 35–55 °C; observe safety restrictions |
|
Power |
Three AA alkaline batteries; 800 hours typical without backlight |
|
Size/weight with holster |
63.5 × 100 × 198.1 mm (H × W × L); 698.5 g |
Current and temperature limits
The 10 A input supports continuous 10 A operation up to 35 °C. From 35 to 55 °C, observe less than 20 minutes on and 5 minutes off. For currents above 10 A up to 20 A, the limit is 30 seconds followed by 5 minutes off; accuracy above 10 A is unspecified. Use a correctly rated compatible current clamp when a task requires higher current without direct series measurement. The temperature input range does not extend the probe’s own limit or the meter’s ambient operating range.
Drive diagnostics and intermittent electrical faults
For motor drives, the selectable low-pass filter suppresses high-frequency components so voltage and frequency readings are more useful on inverter outputs. Filter mode uses manual ranging; check for hazardous voltage without the filter first. Never rely on a filtered reading to establish an electrically safe condition.
Min/Max/Avg tracks changes in the selected measurement, while the 250 µs peak response mode helps identify brief extremes that ordinary readings may miss. Relative mode can help account for test-lead resistance when comparing low-resistance readings. Use these functions in troubleshooting control panels, motors, plant wiring and de-energised continuity checks; the meter is not a substitute for an insulation resistance tester or a waveform recorder.
Manufacturer package and model selection
Fluke lists the 28 II meter with a holster, TL75 test leads (one pair), AC175 alligator clips (one pair), 80BK-A Type-K thermocouple, three AA batteries and quick reference documentation. A magnetic hanger is optional. Regional accessory configurations can differ; confirm the seller’s actual package and quantities for your purchase order.
28 II vs 27 II vs 28 II Ex
The Fluke 27 II shares the rugged enclosure design but uses average-responding AC measurement. The 28 II adds True RMS AC, high-resolution mode, temperature input, peak capture and low-pass filtering for drive work. The 28 II Ex is a separate intrinsically safe product; do not substitute the standard 28 II when hazardous-area certification is required. The standard 28 II has MSHA approval under specified battery conditions, which is not equivalent to Ex approval for all explosive environments.
Compare other Fluke instruments and digital multimeters for a different measurement or environmental requirement.
Ordering and delivery in Ulhasnagar
For Ulhasnagar maintenance purchases, review the product offer with your required quantity and delivery pincode. Under Indus MegaMart’s ordering policy, orders and payment are accepted even when available stock is insufficient or zero. For orders within available stock, delivery is within 7 days. For quantities above available stock, including zero stock, delivery is within 7–14 days. Confirm pincode serviceability before purchase.
Purchase invoices contain the company’s GST number. For bulk requirements or project procurement, contact Indus MegaMart to coordinate quantity, documentation and accessory requirements. Review the current listing price and GST treatment before payment.
Frequently asked questions
1. Is the Fluke 28 II a True RMS multimeter?
Yes. Its AC voltage and current functions are True RMS, within the stated range and frequency limits. That is useful when industrial equipment produces non-sinusoidal AC signals.
2. Can the Fluke 28 II be used in an explosive gas area?
No. The standard 28 II is not the intrinsically safe 28 II Ex. Follow the site hazardous-area requirements and use equipment with the required approval. IP67 alone does not establish suitability.
3. Can this meter measure 20 A continuously?
No. Above 10 A and up to 20 A, the maximum measurement period is 30 seconds, followed by 5 minutes off. Accuracy above 10 A is unspecified.
4. Can I measure temperatures above 260 °C with the supplied probe?
No. The 80BK-A is rated −40 to +260 °C. The meter accepts a broader temperature input, but a compatible higher-rated thermocouple is needed for higher temperatures within the meter range.
5. Does peak recording provide a downloadable waveform?
No. The meter captures extremes using its peak mode; it is not an oscilloscope or a continuous timestamped logging system. Choose a suitable instrument if waveform or event-history recording is required.
6. What warranty and calibration documents should a buyer confirm?
Fluke lists a limited lifetime manufacturer warranty for the 28 II. Confirm applicable seller warranty handling, return terms and whether a calibration certificate is supplied or must be arranged before ordering.
7. How can I order the Fluke 28 II for Ulhasnagar if stock is insufficient?
Indus MegaMart accepts orders and payments even at zero stock. Orders exceeding available stock follow the 7–14 day delivery policy, subject to serviceability of the delivery pincode.
Buy the Fluke 28 II Digital Multimeter — view price and order for Ulhasnagar