Pilz PNOZ e1.1p 24V DC Safety Relay (774133) in Tiruchirappalli
Order Pilz PNOZ e1.1p (774133) through Indus MegaMart for your Tiruchirappalli maintenance or machine-control requirement. This standalone PNOZelog electronic safety relay uses a 24 V DC supply, two solid-state safety outputs and removable screw terminals. It is intended for compatible emergency-stop, guard-monitoring and light-grid safety circuits. Check the exact part number against your machine documentation before buying.
Review the current price, GST basis, listed selling unit and required quantity on the exact product listing. Pilz specifies one device per manufacturer packaging unit; confirm the merchant’s selling unit separately.
Check price and order Pilz 774133
Technical specifications of Pilz 774133
|
Specification |
Detail |
|
Manufacturer/family |
Pilz / PNOZelog |
|
Model/order number |
PNOZ e1.1p / 774133 |
|
GTIN |
4046548011968 |
|
Supply |
24 V DC; −20%/+25% tolerance; 2 W at no load |
|
Input circuit |
Single or dual channel; cross-short detection according to operating mode |
|
Outputs |
2 instantaneous semiconductor safety outputs, 1 auxiliary output, 2 test pulse outputs |
|
Start modes |
Automatic or monitored |
|
Mounting / terminals |
35 mm DIN rail; plug-in screw terminals; flexible conductor 24–12 AWG |
|
Dimensions / weight |
94 × 22.5 × 121 mm (H × W × D); 130 g net |
|
Environment |
−10 to +55 °C; no condensation; housing IP40, terminals IP20; cabinet IP54 or better |
|
Output response time |
40 ms typical; 43 ms maximum (not total machine stopping time) |
|
OEM approvals listed |
CE, UKCA, cULus Listed, TÜV and EAC |
Check the electronic output load before replacing a relay
The two safety outputs are semiconductor outputs, not voltage-free relay contacts. For the DC-12 utilisation category, the manual gives the following load limits, depending on the number of loaded outputs and the supply voltage (UB).
| Loaded safety outputs |
UB ≤ 26.5 V |
UB > 26.5 V |
|
Both outputs |
2 A / 50 W |
1.5 A / 45 W |
|
One output |
2.7 A / 70 W |
2.2 A / 65 W |
The auxiliary and test pulse outputs are rated 24 V, 0.5 A. Output Y32 is for auxiliary signalling, not a safety circuit. The output characteristics and load interface must match the existing safety design; use the manufacturer’s instructions when selecting contactors or expansion modules.
Where the PNOZ e1.1p fits
The relay can monitor emergency-stop devices and safety gate switches. It can also process compatible output signal switching device (OSSD) signals from light grids. Pulsed semiconductor-output sensors are permitted only in the specified operating mode without detection of shorts across contacts. Confirm the sensor specifications and the approved circuit design rather than assuming every light curtain is compatible.
The feedback loop enables monitoring of external contactors; AND/OR logic inputs permit logical interconnection of compatible units. Power and channel LEDs help identify operating status. A qualified safety engineer must assess the selected input and restart mode, sensor interface, output load and complete safety function before commissioning. Matching the supply voltage and enclosure width alone is not sufficient for a safe substitute.
Ordering and delivery for Tiruchirappalli buyers
Select the correct quantity for a panel replacement or planned maintenance purchase. Confirm the selling unit, product condition, applicable GST, warranty, and return terms on the product listing before completing your order. Indus MegaMart purchase invoices include the company GST number.
Orders and payments are accepted even if available stock is insufficient or zero. Under the Indus MegaMart delivery policy, orders within available stock are delivered within 7 days; orders exceeding available stock, including zero-stock orders, have a 7–14-day delivery window. Confirm serviceability and delivery details for your Tiruchirappalli delivery pincode before payment.
For other configurations, browse the wider Pilz range and safety relay category.
View Pilz products
Compare safety relays
Frequently asked questions
1. Is 774133 the same as 784133?
No. 774133 uses plug-in screw terminals; PNOZ e1.1p C (784133) uses spring-loaded terminals. Check the exact order number, terminal arrangement and validated design before replacing one variant with the other.
2. Can 774133 replace a relay with two normally-open dry contacts?
Not automatically. The PNOZ e1.1p has electronic safety outputs rather than isolated mechanical contacts. The downstream interface, test pulses and permitted load require a compatibility check.
3. Does 774133 support a manual reset?
It supports monitored start as well as automatic start. Select the restart arrangement required by the machine safety assessment; automatic start is not suitable for every application.
4. Are spare screw terminals available as a separate OEM accessory?
Pilz lists spare plug-in screw terminal set 374280. The set is a separate accessory; confirm any required accessories and the actual order contents before purchase.
5. Can a filter be used with the PNOZelog output?
Pilz lists filter blocks for specific load ranges. The older 774195 and 774196 accessory codes are discontinued; the manufacturer identifies 772290 and 772291 respectively as follow-up products. Confirm the required load range and suitability against the manual before ordering.
6. How can I check the price and selling quantity for Tiruchirappalli?
Open the exact 774133 listing to review the current offer and quantity options. The manufacturer’s one-unit packaging specification does not establish the price basis or merchant pack size.
Buy Pilz PNOZ e1.1p 24V DC Safety Relay (774133)