Pilz PNOZ yio2 2DI 3NO Expansion Module (2A000015) in Thiruvananthapuram
Order the Pilz PNOZ yio2 2DI 3NO expansion module, part number 2A000015, for a compatible myPNOZ modular safety relay system in Thiruvananthapuram. This 17.5 mm module combines one safety input function with three instantaneous normally-open safety relay contacts. It is designed for a myPNOZ configuration that needs both safety-related input monitoring and relay switching, rather than only an input module or an output module. Check your head module, wiring concept, contact loads and the current Indus MegaMart product offer before ordering.
Buy Pilz 2A000015 for Delivery in Thiruvananthapuram
Use the Indus MegaMart listing for Pilz PNOZ yio2 2DI 3NO to review the current selling price, applicable GST, quantity and the exact product selected. Check the destination pincode for delivery serviceability, confirm the offered sale unit and any required terminal accessories, and continue through the product listing to place the order.
Orders and payment are accepted even when requested quantity exceeds displayed inventory or available stock is zero. Under Indus MegaMart’s stated order policy, delivery is within 7 days when ordered quantity is within available stock, and within 7–14 days when the quantity exceeds stock or stock is zero. Delivery to a particular Thiruvananthapuram pincode remains subject to the checkout serviceability check.
For machine builders, plant maintenance teams and industrial procurement staff in Thiruvananthapuram, the practical buying checks are exact Pilz MPN 2A000015, the existing myPNOZ system design, the needed three N/O safe contacts, connected load category, terminal accessories, required quantity and GST-inclusive checkout value.
What the PNOZ yio2 2DI 3NO Module Does
PNOZ yio2 is a combined input/output expansion module for the Pilz myPNOZ modular safety relay family. Two 24 V DC digital inputs monitor one safety-related input function; the module provides three positively guided, instantaneous normally-open relay safety outputs for the system’s designed safe switching circuit. A feedback-loop input allows external switching-device feedback to be considered in the safety circuit configuration.
A rotary switch supports start-type and test-pulse evaluation settings, while LED indicators help with local status checks. Diagnostic signal outputs are distinct from the three safety relay contacts: do not use a diagnostic signal output as a safety-rated switching contact.
Pilz PNOZ yio2 2A000015 Technical Specifications
|
Product attribute |
Verified model detail |
|
Brand / exact model |
Pilz PNOZ yio2 2DI 3NO; part number 2A000015 |
|
GTIN |
4046548090987 |
|
System family |
myPNOZ modular safety relay system |
|
Module type |
Combined safety input / relay-output expansion module |
|
Input function |
One safety-related input function; 2 digital inputs, 24 V DC |
|
Safe switching contacts |
3 positively guided normally-open (N/O) instantaneous relay safety contacts |
|
Output function |
One safe relay output function (3 N/O contacts); includes a feedback-loop input |
|
Diagnostics / adjustment |
Diagnostic signal outputs, rotary start-mode and test-pulse evaluation switch, LED indication |
|
Internal module power |
DC supply provided via compatible myPNOZ head module; not a standalone 24 V DC supply input specification |
|
Contact load example |
AC1: 6 A at 240 V AC; DC1: 6 A at 24 V DC; rating depends on usage category and application |
|
Dimensions (H × W × D) |
98 × 17.5 × 121 mm |
|
Mounting / protection |
35 mm DIN rail; housing/terminals IP20 |
|
OEM package quantity |
1 device per OEM packaging unit; Indus MegaMart sales pack requires confirmation |
|
Connection accessories |
Pilz lists 750003 screw-terminal or 751003 spring-terminal set for 17.5 mm housing; inclusion not verified |
myPNOZ Compatibility and Safety-Circuit Selection
Use it with a myPNOZ head module
PNOZ yio2 requires a compatible myPNOZ head module and is not a standalone safety relay. Its internal module supply is provided through the myPNOZ head module. Pilz describes a myPNOZ assembly as one head module with at least one expansion module, subject to the allowed system configuration. Do not assume this part is interchangeable with a PNOZmulti or PNOZmulti 2 expansion module.
Confirm relay-contact type and switching load
This version provides three instantaneous N/O relay safety contacts. These are different from the semiconductor outputs offered by PNOZ yio1 and from the delayed relay contact behavior of PNOZ yio4. For the specified AC1 resistive-duty category, Pilz lists 6 A at 240 V AC; switching suitability for other load categories must be checked in the exact OEM technical data and safety-circuit design.
Check installation space, terminals and wiring
The module measures 98 mm high, 17.5 mm wide and 121 mm deep and installs on a 35 mm DIN rail. Its housing is IP20, so the protective enclosure and environmental conditions must be suitable. Pilz identifies 17.5 mm screw-terminal and spring-terminal accessory sets; confirm which terminal set, if any, is included in the merchant’s offered pack before finalising a replacement or new panel order.
Applications That Fit This Input/Output Module
In a validated myPNOZ architecture, PNOZ yio2 can be selected where a monitored safety input and three safe relay contacts are needed in the same module. Potential use cases include safety-gate monitoring on packaging equipment, an emergency-stop safety function on a conveyor or safety-related control within a machine cell. These are application examples, not statements that the module independently guarantees safety performance or can be installed without system validation.
Before commissioning, the responsible engineer should verify channel wiring, start and reset behavior, feedback-loop wiring, relay load ratings, configured module sequence and the required performance level for the complete machine safety function.
Frequently Asked Questions About Pilz PNOZ yio2
1. Is PNOZ yio2 2A000015 an input module or an output module?
It is a combined input/output expansion module. It provides two digital inputs for one safety-related input function and three instantaneous N/O safety relay contacts in a myPNOZ system.
2. Can PNOZ yio2 2DI 3NO run without a myPNOZ head module?
No. It is an expansion module, not a standalone safety relay. It obtains internal module power through the compatible myPNOZ head module.
3. Does this model work with PNOZmulti controllers?
It belongs to the Pilz myPNOZ family. It should not be ordered as a direct PNOZmulti or PNOZmulti 2 I/O replacement without manufacturer-confirmed compatibility.
4. Does it offer three safe relay contacts or three semiconductor outputs?
Part 2A000015 provides three positively guided, instantaneous normally-open safety relay contacts. For semiconductor output requirements, compare the appropriate myPNOZ module variant instead.
5. Are plug-in connection terminals included with the product?
Pilz lists appropriate screw-terminal and spring-terminal sets as connection accessories, but the Indus MegaMart sale pack has not been confirmed here. Check the listed selling unit and supplied terminals before ordering.
6. What happens if the required quantity is above available stock?
You may still place the order and complete payment. Indus MegaMart’s policy specifies delivery within 7–14 days for quantities above available stock, including zero-stock orders, subject to delivery serviceability.
7. How do I check price, GST and delivery for Thiruvananthapuram?
Open the exact Indus MegaMart product listing to view the current price and GST, select your quantity and use the delivery-pincode check before completing the purchase.