Buy Pilz PNOZ X10.1 774749 Safety Relay 24 V DC 6 NO + 4 NC in Solan
Looking for Pilz PNOZ X10.1, manufacturer part 774749, for a safety-control panel or industrial machine in Solan? This is a standalone 24 V DC PNOZ X safety relay with six instantaneous normally open (NO) safety contacts, four normally closed (NC) auxiliary contacts, and six LED status indicators. It is designed for correctly engineered emergency-stop and safety-gate monitoring applications. The four NC contacts are not safety outputs and must not be wired as safety contacts.
Check the exact Pilz 774749 product offer and proceed to purchase on Indus MegaMart. Confirm the current price, GST, seller unit, quantity and Solan delivery at the live checkout before payment.
Pilz PNOZ X10.1 774749 — Manufacturer-Verified Specifications
|
Specification |
Exact-model detail |
|
Brand and series |
Pilz; PNOZ X10.1, PNOZ X safety relay family |
|
Manufacturer part number |
774749 |
|
GTIN |
4046548010275 |
|
Device type |
Standalone safety relay for suitably engineered safety functions |
|
Rated supply voltage |
24 V DC |
|
Safety contacts |
6 instantaneous NO safety contacts |
|
Auxiliary contacts |
4 instantaneous NC contacts; not for safety circuits |
|
Safety output terminal pairs |
13–14, 23–24, 33–34, 43–44, 53–54, 63–64 |
|
Auxiliary terminal pairs |
71–72, 81–82, 91–92, 01–02 |
|
Input modes |
Single- or dual-channel; detection of shorts across contacts depends on wiring mode |
|
Starting options |
Automatic, manual, monitored start; configuration per Pilz manual |
|
Status display |
6 LEDs for power, channel inputs and internal relay/start status |
|
Terminal type |
Fixed screw terminals |
|
Power consumption |
5.5 W |
|
Width × height × depth |
90 × 87 × 121 mm |
|
Installation |
35 mm DIN rail in a suitable control cabinet |
|
Housing protection |
IP40; cabinet protection is a separate requirement |
|
Ambient temperature |
−10 °C to +55 °C |
|
Net weight |
550 g |
|
Manufacturer package quantity |
One relay; Indus MegaMart selling unit requires live confirmation |
Why Choose PNOZ X10.1 for a Machine Safety Circuit?
Six separate safety outputs. The six positive-guided NO safety contacts provide defined outputs for a machine safety design. A stop-function design must still follow the Pilz operating manual, the equipment risk assessment, contact-load limits and applicable safety standards. More contact pairs do not automatically mean a higher overall machine safety rating.
Four auxiliary contacts for indication. Four NC contacts can support appropriate non-safety status or signalling functions. Pilz explicitly says 71–72, 81–82, 91–92 and 01–02 must not be used in safety circuits. This distinction matters when replacing a relay or reproducing an existing panel wiring diagram.
Six visible LED indicators. The device provides status indication for power, the two input channels and its internal switching/start state. These indicators support troubleshooting by qualified personnel; they do not replace safety validation or electrical testing.
Flexible input and restart arrangements. Pilz documents single-channel and dual-channel input arrangements and automatic, manual and monitored start modes. Choose an arrangement only after checking the machine's risk assessment and Pilz's wiring diagrams. Safety gates, emergency-stop buttons and suitable light-grid applications require the correct sensors, wiring and commissioning tests.
Check Compatibility Before Ordering
Match 774749 exactly with the installed relay label and the machine's electrical drawings. Verify the 24 V DC power supply, fixed screw terminals, 90 mm panel width, required contact count, restart behaviour and input monitoring scheme. A similar-looking PNOZ X10 (774709) has a different LED configuration, and PNOZ X10.11P (777750) is a separate model; neither should be substituted solely on contact count. The 774746 PNOZ X10.1 is an AC-supply variant, not the requested DC unit.
Installation and functional tests should be performed by competent personnel. Pilz specifies a 35 mm DIN rail and a control cabinet with at least IP54 protection. The relay's housing IP40 rating does not make an unprotected panel IP54. Electrical loads must be checked against their relevant utilisation category and protective-device requirements; an 8 A AC1/DC1 value is not a universal contact rating for every load type.
Buy Pilz 774749 in Solan — Price, Availability and Delivery
For factory maintenance teams, panel builders and industrial procurement buyers in Solan, use the exact national product page to review the current Indus MegaMart offer and purchasing conditions. A manufacturer package quantity of one is not proof of the store's minimum order quantity. Confirm the correct product image, part number, GST invoice, total landed price and delivery pincode at checkout.
Indus MegaMart's stated order policy allows orders and payment even when the available stock is zero. If the ordered quantity does not exceed available stock, the stated delivery period is within 7 days. If the ordered quantity exceeds available stock, or available stock is zero, the stated period is 7–14 days. This is the business's conditional policy, not a verified delivery commitment for any particular Solan address. Confirm stock, payment flow and the displayed delivery estimate on the live site.
Frequently Asked Questions
1. Is Pilz PNOZ X10.1 774749 a complete safety relay or only a contact expansion module?
It is a standalone PNOZ X10.1 safety relay, not a PZE contact-expansion accessory. It supports safety-related monitoring in a correctly designed circuit, subject to its documented application and installation requirements.
2. How many contacts can be used as safety outputs?
The relay has six instantaneous NO safety contacts. The other four NC contacts are auxiliary for suitable non-safety use and must not be counted as additional safety outputs.
3. What supply voltage does 774749 require?
24 V DC. The similarly named 774746 model has a different supply specification. Confirm the actual panel supply and the exact nameplate before purchasing.
4. What do the six LED indicators show?
They indicate POWER, CH.1 IN, CH.2 IN, K1, K2 and K3, supporting diagnosis of supply, input channels and switching/start states. Their meaning must be interpreted using Pilz's operating manual.
5. Can the four NC auxiliary contacts be wired into an emergency-stop safety circuit?
No. Pilz specifically prohibits using auxiliary contacts 71–72, 81–82, 91–92 and 01–02 for safety circuits. Only the defined NO safety contacts can be used for safety outputs in the approved design.
6. Does it support both single-channel and dual-channel monitoring?
Yes. The manufacturer documents both. Detection of shorts across contacts depends on the selected wiring arrangement; a qualified machine-safety engineer must select and validate the configuration.
7. Is it compatible with every PNOZ X10 or PNOZsigma replacement?
No automatic compatibility is implied. Compare the exact part number, supply, terminal arrangement, number of LEDs, relay functions and wiring diagrams. PNOZ X10, X10.1 and X10.11P are distinct products.
8. Does it mount on a DIN rail, and what cabinet protection is needed?
Yes, on a 35 mm DIN rail. Pilz requires a suitably protected control cabinet, at least IP54 according to the operating manual, with qualified wiring and commissioning.
9. Where can I see the live Pilz 774749 price and Solan delivery estimate?
Open the Indus MegaMart Pilz PNOZ X10.1 774749 product page and check the current offer, taxes, quantity, payment acceptance and delivery information for your Solan pincode.
Buy Pilz PNOZ X10.1 774749 Safety Relay — check current price and Solan delivery