Order the Fluke 287 True RMS Logging Digital Multimeter from Indus MegaMart for electronics diagnostics, maintenance and engineering work in Siliguri. Unlike a spot-reading measurement tool, the 287 can record changes in a selected electrical parameter and display the history through TrendCapture. Its 50,000-count backlit display, 1000 V AC/DC voltage range and 0.025% basic DC voltage accuracy make it a practical choice when a fault appears only intermittently or when a design needs to be checked over a sustained test period. Before ordering, review the exact model, current GST-inclusive price, selling quantity and delivery details for your Siliguri pincode.
Buy Fluke 287 / check current price and delivery
Order the exact Fluke 287 for Siliguri delivery
The product listing shows the GST-inclusive price and corresponding taxable value. Confirm the selling unit and supplied items before ordering, particularly when a purchase order specifies accessories or calibration documentation. Purchase invoices carry the company GST number. Orders and payment are accepted even when the requested quantity exceeds available stock or stock is zero. Under the ordering policy, delivery is within 7 days for quantities covered by available stock; quantities exceeding stock, including zero-stock orders, have a 7–14 day delivery window. Check the delivery details for your destination pincode.
Fluke 287 technical specifications
|
Parameter |
Specification |
|
Model / type |
Fluke 287; handheld True RMS electronics logging DMM |
|
AC/DC voltage |
50 mV to 1000 V ranges; 1 µV finest DC resolution |
|
AC/DC current |
500 µA through 10 A ranges |
|
Resistance |
Up to 500 MΩ |
|
Capacitance |
1 nF through 100 mF ranges |
|
Frequency |
0.5 Hz to 999.99 kHz, subject to input conditions |
|
Temperature |
−200 to +1350 °C meter range; probe limits apply |
|
Display |
50,000 counts with backlight; multiple readouts |
|
Basic DC voltage accuracy |
0.025% on specified ranges; consult full accuracy table |
|
AC bandwidth |
Up to 100 kHz, range dependent |
|
Logging |
Interval and event recording; TrendCapture; up to 14× zoom |
|
Memory |
10,000 sample intervals maximum; event capacity 15,000 minus intervals; reduced with less memory |
|
Peak capture |
250 µs; not a waveform recorder |
|
Other functions |
Continuity, diode, conductance 50 nS range, duty cycle, pulse width, relative mode, MIN/MAX/AVG, dBV/dBm, Hold/AutoHold |
|
Safety |
CAT III 1000 V / CAT IV 600 V; maximum terminal-to-earth 1000 V |
|
Power |
6 AA alkaline; minimum 100 h, up to 200 h logging under specified conditions |
|
Size / weight |
222 × 102 × 60 mm; approximately 871 g |
|
Environment |
Operating −20 to +55 °C; storage −40 to +60 °C |
Accuracy varies by function, selected range, frequency and operating conditions. Refer to the full Fluke accuracy tables for tolerance-critical work. For the current input, do not treat the short-duration 20 A allowance as a continuous or accuracy-rated measurement range.
When logging changes the troubleshooting workflow
A momentary voltage drop may disappear before a technician reaches the panel. Recording the voltage over an appropriate interval can reveal when the disturbance occurred and how long it persisted. The adjustable event threshold helps identify changing readings; TrendCapture allows review on the meter itself, including zooming into a section of a recorded trend. Set the monitoring duration with available memory, expected event frequency and battery condition in mind. Save the recording before closing the session.
Electronics development and test benches
Use the 287 to observe a DC supply rail, check low-current circuit behaviour, or compare component readings before and after a controlled test. The fine DC voltage resolution and relative mode are useful when small changes matter. For simultaneous measurements on several independent circuits, choose a multi-channel data acquisition system instead.
Maintenance and intermittent equipment faults
A service engineer can use logged readings to correlate a single supply variation with a machine symptom. True RMS AC measurements are helpful for distorted signals within the meter’s specified bandwidth and crest-factor limits. The selectable AC smoothing filter helps stabilize a noisy display; it is not a dedicated variable-frequency-drive output filter. For safe unattended logging, use an approved setup, suitable rated leads and a trained operator. Never exceed the lowest rating of the meter, leads or accessories; isolate and discharge circuits before resistance or capacitance testing.
Base instrument, accessories and model selection
Fluke’s standard 287 package lists the meter, one pair of TL71 test leads, one pair of AC175 alligator clips, six installed AA batteries and a quick reference guide. Verify the actual Indus MegaMart selling pack before ordering. The temperature function requires a compatible thermocouple probe; Fluke lists the 80BK as optional. FlukeView Forms software with cable (FVF-SC2), TLK287 lead set, TPAK magnetic hanger and C280 case are optional accessories, not assumed to be included. The ir3000 FC connector is also optional.
Choose the 287 when detailed electronics measurements and on-device logging are the priority. The related Fluke 289 adds functions specific to that model, such as the low-impedance voltage mode and 50 Ω range. If your work only requires occasional spot measurements, a simpler digital multimeter may be sufficient. For wider product selection, explore the following ranges:
Digital multimeters
Fluke instruments
Test and measurement instruments
Frequently asked questions
1. How many readings can the Fluke 287 store?
It can record up to 10,000 sample intervals. The maximum number of event records is 15,000 minus the number of sample intervals, and both limits decrease when available memory is low. Choose the interval and recording duration accordingly.
2. Do I need a computer to see logged readings?
No. TrendCapture displays recorded trends on the instrument. PC reporting requires compatible interface hardware and software, such as the optional FlukeView Forms package.
3. Can resistance and temperature be logged simultaneously?
No. The 287 can record either resistance or temperature in a session, not both at once. Use a suitable multi-channel instrument if simultaneous correlation is essential.
4. Can I measure 20 A continuously?
No. The 287 is rated for measurements up to 10 A on its A input. The manual permits 20 A for 30 seconds followed by 10 minutes off, with accuracy above 10 A unspecified. Use an appropriately rated current clamp and compatible meter setup for higher sustained currents.
5. Does Fluke Connect work without another accessory?
No. Wireless communication requires the optional ir3000 FC infrared connector and a compatible app. Check the accessory and software availability before ordering.
6. Is the Fluke 287 suitable for insulation or power-quality testing?
It measures resistance and can log individual electrical parameters, but it is not a dedicated insulation resistance tester or multi-channel power-quality analyzer. Select those instruments when insulation test voltage, energy, harmonics or simultaneous phase measurements are required.
7. What is the difference between the Fluke 287 and the 287/FVF kit?
The 287 is the base logging multimeter. The 287/FVF is a separate kit configuration; confirm its software, cable and other inclusions against the exact kit listing if you need PC reporting.
8. Can I obtain a calibration certificate or warranty support with my order?
Fluke lists a limited lifetime manufacturer warranty subject to its terms. Confirm the warranty applicability, service route and any requested calibration documentation with Indus MegaMart before placing a procurement order.
9. Can I order multiple Fluke 287 meters for a Siliguri site?
Yes. Select the required order quantity on the product listing. Orders and payments are accepted even if the requested quantity exceeds available stock. Invoices carry the company GST number; check the delivery details for your destination pincode.
Order the Fluke 287 True RMS Logging Digital Multimeter for Siliguri