Pilz PNOZ XV1P C Safety Relays 3/24VDC 2n/o 1n/o t (787601) is a safety relay designed to monitor safety inputs and provide controlled, time-delayed output switching. It supports applications where safe shutdown and timed restart or delay functions are required in industrial safety circuits
What is Pilz PNOZ XV1P C Safety Relays 3/24VDC 2n/o 1n/o t (787601)
Unlike standard instantaneous relays, this model incorporates a timing function (“t”) that allows delayed switching or controlled reset behavior. This is particularly useful in systems where immediate shutdown is not always appropriate, or where restart conditions must be sequenced.
It is commonly used in applications where mechanical inertia, process continuation, or safety interlocking requires a defined delay. The relay enables safer transitions between operational states while maintaining compliance with safety circuit logic.
Applications of Pilz PNOZ XV1P C Safety Relays 3/24VDC 2n/o 1n/o t (787601)
• Conveyor Systems with Delayed Stop Requirements: Prevents abrupt stoppage, allowing materials to clear before shutdown.
• Machine Tools with Spindle Run-Down Time: Ensures machines complete motion safely before disconnecting power.
• Automated Packaging Lines with Sequential Shutdown: Maintains process continuity while executing controlled stop logic.
• Dust Extraction and Ventilation Systems: Allows fans to run briefly after machine stop for safe clearing.
• Food Processing Equipment: Supports controlled stop to avoid product damage or system shock.
• Batch Processing Systems: Enables timed transitions between operational phases.
Industries Using Pilz PNOZ XV1P C Safety Relays 3/24VDC 2n/o 1n/o t (787601)
This relay is used in industries where timing and controlled stopping are essential:
• Food and beverage processing
• Packaging and material handling
• Woodworking and machine tools
• Textile machinery
• Bulk material processing
• Industrial ventilation systems
These environments often require safety systems that consider process timing rather than immediate shutdown.
Operational Considerations
When using the Pilz PNOZ XV1P C Safety Relays 3/24VDC 2n/o 1n/o t (787601):
• Timing Requirement Definition: Clearly define delay duration required for safe operation.
• Application Suitability: Ensure that delayed shutdown does not compromise safety compliance.
• Integration with Control Logic: Coordinate timing with PLC or system control sequences.
• Load Handling During Delay: Verify system stability during the delay period.
• Maintenance of Timing Accuracy: Periodic checks may be required in critical applications.
Customization Options
Indus Megamart supplies standard relay configurations without modification.
Support includes:
• Selection assistance based on timing requirements
• Guidance on integrating delay functions into safety circuits
• Help in identifying compatible relay variants
Product Supply & Distribution Capability
Indus Megamart supplies and distributes Pilz safety relays across industrial sectors.
Capabilities include:
• Support for OEM and system integrator procurement
• Bulk and repeat supply handling
• Replacement supply for maintenance requirements
• Coordination for urgent dispatch
Indus Megamart focuses on ensuring reliable product availability.
Supply Across India
Indus Megamart supports Pan India delivery including:
• Northern industrial clusters
• Western manufacturing regions
• Southern automation hubs
• Eastern industrial zones
Logistics are aligned with project schedules and maintenance needs.
Export Capability
Indus Megamart supports export orders for international clients. Packaging and logistics are managed according to destination requirements.
How to Choose the Right Pilz PNOZ XV1P C Safety Relays 3/24VDC 2n/o 1n/o t (787601)
This relay is selected when timing behavior is critical to safety.
Buyer Checklist:
• Does your application require delayed shutdown or restart?
• Is the timing function essential for process safety?
• Are 2 NO and 1 timed NO outputs sufficient?
• Is the system sensitive to abrupt stoppage?
• Is the relay being used in a sequencing or batch process?
• Are safety standards compatible with delayed response?
Refer to internal guides for deeper selection insights.
Comparison Table
Time-delay relays are selected for specific operational needs.
Feature |
PNOZ XV1P C |
PNOZ X3P C |
PNOZ X3.10P C |
|
Timing Function |
Yes |
No |
Controlled |
|
Output Type |
Timed NO |
Standard |
Controlled |
|
Application |
Delayed shutdown |
General safety |
Sequenced systems |
|
Complexity |
Moderate |
Moderate |
Higher |
This comparison helps identify when timing functionality is required.
Typical Use Case Scenarios
• Material Conveyor Line: Ensures safe clearing before shutdown.
• Industrial Dust Collection System: Maintains airflow after machine stop.
• Woodworking Machine: Allows spindle to decelerate safely.
• Batch Processing Unit: Controls transition timing between cycles.
Procurement Process
To procure the Pilz PNOZ XV1P C Safety Relays 3/24VDC 2n/o 1n/o t (787601):
- Submit enquiry:
https://www.indusmegamart.com/contact-us - Share application details
- Confirm pricing and availability
- Finalize order and dispatch
Company details:
https://www.indusmegamart.com/about-us
Common Buyer Concerns Before Ordering
• Whether timing function matches application needs
• Safety compliance with delayed shutdown
• Output configuration compatibility
• Integration with existing control systems
• Availability for urgent replacement
Addressing these ensures correct product selection.
FAQ Section
What does the “t” indicate in this relay?
It indicates a time-delay function, allowing outputs to switch after a defined delay rather than instantly.
Where is this relay typically used?
It is used in applications where controlled shutdown or delayed restart is required, such as conveyors or ventilation systems.
Can it replace a standard safety relay?
It can replace standard relays only if the application benefits from a timing function.
Does it require programming?
No, it operates through wiring logic and built-in timing functionality.
Is it suitable for high-speed systems?
Yes, if the timing requirements align with system safety needs.
What should be checked before installation?
Verify timing requirements, output configuration, and compatibility with system logic.
Can it be used in retrofit projects?
Yes, especially where timing functionality needs to be added to existing systems.
Request a Quote for Pilz PNOZ XV1P C Safety Relays 3/24VDC 2n/o 1n/o t (787601)
Indus Megamart supplies and distributes industrial safety relays across India. Contact the team for pricing, availability, and technical support.
Contact Information for
• Pricing enquiries
• Technical discussions
• Bulk orders
Visit: https://www.indusmegamart.com/contact-us
Specifications may vary depending on application requirements.
Product Specifications
Indus Megamart supplies this relay based on standard industrial configurations. Exact specifications should be confirmed during procurement.
|
Parameter |
Description |
|
Supply Voltage |
3/24V DC |
|
Relay Type |
Safety relay with time delay |
|
Output Configuration |
2 NO + 1 timed NO |
|
Mounting |
DIN rail |
|
Terminal Type |
Plug-in (P variant) |
|
Functional Feature |
Time-delayed switching |
|
Application Scope |
Controlled shutdown and restart |
Customer reviews