Buy Pilz 750126 PNOZ s6.1 Safety Relay 24V DC 3NO 1NC in Roorkee
Pilz 750126 PNOZ s6.1 is a standalone PNOZsigma safety relay for Type IIIA two-hand control and simultaneity monitoring, with 24 V DC supply, three normally open safety contacts and one normally closed auxiliary contact. It has a separate semiconductor status output and removable screw terminals in a 22.5 mm-wide housing. Buyers in Roorkee can order the exact 750126 through Indus MegaMart. Choose this version only if the machine’s risk assessment and circuit design suit its operating mode; it is not a relay for press controllers.
Check the current GST-inclusive price, available quantity and delivery pincode on the product listing. Pilz specifies one relay per manufacturer packaging unit; confirm the offered selling unit, quantity and product condition before purchase. For project quantities, verify the required part number against your bill of materials.
Buy Now — Pilz PNOZ s6.1 (750126)
Technical specifications of Pilz 750126
|
Parameter |
Specification |
|
Brand/model / MPN |
Pilz / PNOZ s6.1 / 750126 |
|
Series/relay type |
PNOZsigma; standalone Type IIIA two-hand safety relay |
|
GTIN |
4046548045895 |
|
Supply/consumption |
24 V DC, −15% / +10%; 3.5 W |
|
Inputs |
2 channels; cross-short detection in prescribed circuit; one NO per two-hand pushbutton |
|
Safety contacts |
3 instantaneous NO; positively guided |
|
Auxiliary outputs |
1 instantaneous NC; 1 semiconductor output (24 V DC, 20 mA); neither safety-rated output |
|
Contact load, AC-1 / DC-1 |
6 A at 240 V AC / 6 A at 24 V DC |
|
Contact load, AC-15 / DC-13 |
5 A at 230 V AC / 5 A at 24 V DC (6 cycles/min for DC-13) |
|
Thermal current |
6 A per contact at DC supply, AC-1/DC-1, with one, two or three contacts loaded; observe all load and service-life limits |
|
Simultaneity / response |
Max. 0.5 s between channels; NO de-energisation 40 ms; NC 50 ms; recovery 250 ms |
|
Terminals / mounting |
Plug-in screw terminals; 35 mm DIN rail |
|
Size / net weight |
98 × 22.5 × 120 mm (H × W × D); 185 g |
|
Environment / protection |
−10 to +55 °C; no condensation; housing IP40, terminals IP20; cabinet at least IP54 |
|
OEM packaging unit |
1 relay per manufacturer packaging unit |
|
Approvals listed by Pilz |
CE, CCC, EAC, TÜV, UKCA, cULus Listed (device-level; not machine approval) |
Two-hand operating principle and application limits
The relay checks that both control elements are operated within 0.5 seconds. Releasing either control removes the enable command. Both controls must be released before a new simultaneous actuation. This makes the relay relevant for appropriately assessed low-risk two-hand operating stations, rather than general high-risk press control. One NO contact per pushbutton is required in the two-hand circuit.
PNOZ s6.1 also supports emergency-stop and safety-gate applications using the circuits specified by Pilz. The safety characteristics depend on the function: two-hand operation is PL c, Category 1, SIL 1; E-stop/safety-gate operation is PL e, Category 4, SIL 3 at the device level under the applicable conditions. These figures do not establish the achieved performance level of an assembled machine. In the prescribed automatic-start gate/E-stop arrangement, external measures must prevent unintended restart. Do not assume a selectable manual/automatic reset mode or direct compatibility with light curtains. Use the manufacturer’s operating manual and a qualified machine-safety assessment.
Load and installation checks before replacement
Match both the 24 V DC supply and the output load category. A 6 A resistive-load rating is not a blanket rating for contactor coils: AC-15 and DC-13 have their own limits as shown above. Evaluate contact protection, electrical service life, contactor feedback and the total circuit response time. The feedback circuit does not itself detect cross-shorts or short circuits; appropriate fault-exclusion measures are necessary. Use a compliant SELV/PELV power supply and an IP54 or better control cabinet. A qualified person should validate the safety function during commissioning and after changes.
Where more contacts are needed, the manufacturer permits one compatible PNOZsigma contact-expansion module. In a standalone installation, the side terminator is required. Pilz lists spare screw-terminal set 750004 and terminator pack 750010 as separate accessories; check your order contents rather than assuming additional accessories are included. Status LEDs help identify channel, supply, output, feedback and fault conditions.
Compare PNOZ s6.1 variants before ordering
|
MPN |
Supply |
Connection |
|
750126 (this item) |
24 V DC |
Plug-in screw |
|
751126 (s6.1 C) |
24 V DC |
Plug-in spring-loaded |
|
750156 |
48–240 V AC/DC |
Plug-in screw |
|
751156 (s6.1 C) |
48–240 V AC/DC |
Plug-in spring-loaded |
PNOZ s6 (rather than s6.1) is a Type IIIC two-hand relay that uses one NO and one NC per pushbutton. Do not choose either solely from the number of output contacts; compare the required safety function, input contacts, supply and wiring.
Browse Pilz products
Explore safety relays
Ordering and delivery in Roorkee
For a serviceable delivery pincode, Indus MegaMart’s order policy is delivery within 7 days when the quantity is within available stock and 7–14 days when the order exceeds stock or stock is zero. Orders and payments are accepted in either case. Check your delivery pincode and quantity before completing the purchase. Purchase invoices contain the company’s GST number. Confirm the product condition, applicable warranty and return terms for the exact unit before ordering.
Frequently asked questions
1. Is the PNOZ s6.1 750126 suitable for press safety?
No. Pilz specifies the s6.1 for Type IIIA two-hand operation where the assessed risk is low and excludes press controllers. A Type IIIC or another safety solution may be required; have the machine’s safety design assessed before selecting a replacement.
2. Can the 1 NC contact or the semiconductor output be used in a safety circuit?
No. Only the three NO relay contacts are the safety outputs. The NC contact and semiconductor output are for auxiliary signalling or status information, not for the safety function.
3. Can more safety contacts be added to the 750126?
One compatible PNOZsigma contact-expansion module can be connected using the manufacturer’s prescribed connector arrangement. Verify the required expansion and its safety characteristics before ordering; accessories are not assumed to be included.
4. Can the 750126 replace a PNOZ s6 or a 751126?
Not automatically. The s6 and s6.1 have different two-hand control types and input-contact requirements. SKU 751126 uses spring-loaded terminals rather than the plug-in screw terminals of 750126. Match the exact part number and confirm the approved circuit before substitution.
5. Can I order a quantity greater than the stock shown?
Yes. Indus MegaMart accepts orders and payment even if available stock does not cover the requested quantity or is zero. The applicable policy is delivery within 7–14 days for these orders, subject to serviceability at the delivery pincode.
Order Pilz 750126 PNOZ s6.1 Safety Relay — view current price and purchase