Fluke 77 IV Digital Multimeter Supplier in Punjab
For maintenance stores, field-service teams and electronics repair benches in Punjab, the Fluke 77 IV is a handheld, average-responding digital multimeter with a 1000 V AC/DC voltage range, 10 A current measurement and a 6000-count display. It also measures resistance, capacitance and frequency and provides continuity and diode tests. Its CAT III 1000 V / CAT IV 600 V ratings make it a useful candidate when selecting equipment for appropriately rated electrical distribution work. Unlike a True RMS meter, the 77 IV is intended for conventional sinusoidal AC readings.
Order the exact Fluke 77 IV through Indus MegaMart. The manufacturer’s ordering code is Fluke-77-4; confirm the supplied variant before purchase. Review the current price, GST total, selling unit and quantity on the product listing, then confirm serviceability for your Punjab delivery address before payment.
Check Fluke 77 IV price and buy online
Order quantity, GST and delivery in Punjab
Indus MegaMart accepts orders and payments even if the available quantity is zero or less than the quantity requested. Under its delivery policy, orders within available stock are delivered within 7 days; quantities above available stock, including zero-stock orders, follow a 7–14 day delivery window, subject to serviceability at the destination. Confirm the applicable delivery estimate when ordering. Purchase invoices contain the company’s GST number. For tool-room replenishment or a multi-meter procurement request, verify the commercial pack, required accessories and warranty terms before confirming quantities.
Fluke 77 IV measurement specifications
The ranges below follow the Fluke 77 Series IV user manual. Accuracy is expressed as ±(% of reading + counts), with manual accuracy conditions of 18–28°C, 0–90% RH and one year after calibration. Check the supplied meter’s documentation revision for engineering acceptance limits.
| Function |
Selectable ranges |
Resolution span |
Accuracy / restriction |
|
AC voltage |
6 / 60 / 600 / 1000 V |
1 mV to 1 V |
2.0% + 2; 45 Hz–1 kHz |
|
DC millivolts |
600.0 mV |
0.1 mV |
0.3% + 1 |
|
DC voltage |
6 / 60 / 600 / 1000 V |
1 mV to 1 V |
0.3% + 1 |
|
AC current |
60 / 400 mA; 6 / 10 A |
0.01 mA to 0.01 A |
2.5% + 2; 45 Hz–1 kHz |
|
DC current |
60 / 400 mA; 6 / 10 A |
0.01 mA to 0.01 A |
1.5% + 2 |
|
Resistance |
600 Ω; 6 / 60 / 600 kΩ; 6 / 50 MΩ |
0.1 Ω to 10 kΩ |
0.5% + 2 at 600 Ω; 0.5% + 1 through 6 MΩ; 2% + 1 at 50 MΩ |
|
Capacitance |
1000 nF; 10 / 100 / 9999 µF |
1 nF to 1 µF |
1.2% + 2 through 1000 µF; above 1000 µF on highest range: 10% typical |
|
Frequency (AC voltage input) |
99.99 / 999.9 Hz; 9.999 / 99.99 kHz |
0.01 Hz to 10 Hz |
0.1% + 1; specified 2 Hz–99.99 kHz |
|
Continuity |
600 Ω |
1 Ω |
Buzzer on below 25 Ω; off above 250 Ω; detects events ≥250 µs |
|
Diode |
2.400 V |
1 mV |
1% + 2 |
Display, protection and physical specifications
The backlit 6000-count display updates four times per second; the 33-segment bar graph updates 32 times per second. Auto and manual ranging are available. MIN MAX AVG records extrema and running average; AutoHOLD retains stable readings. The bar graph is disabled for capacitance. The meter has a molded housing with probe holders, a 20-minute sleep function, and a 9 V alkaline battery with approximately 400 hours of typical life.
Safety: IEC 61010-1 pollution degree 2 and IEC 61010-2-033 CAT III 1000 V / CAT IV 600 V. Surge protection is specified at 8 kV peak by Fluke’s product page. Maximum terminal-to-earth voltage: 1000 V. Fuse protection: 440 mA, 1000 V fast fuse (Fluke 943121) and 11 A, 1000 V fast fuse (Fluke 803293). Dimensions: 185 × 90 × 43 mm (length × width × depth); weight: 420 g. Operating temperature: −10 to +50°C; storage: −40 to +60°C; operating altitude: 2000 m. Non-condensing humidity limits: 90% to 35°C, 75% to 40°C and 45% to 50°C.
Where the 77 IV fits in a maintenance kit
Electrical distribution and field service
Use the meter for appropriately rated voltage checks and conventional AC/DC diagnostics performed by qualified personnel. The wide voltage range, fast bar graph and recording functions help distinguish a steady input from a changing reading. Use correctly rated probes and protective caps in CAT III/IV environments; the lowest-rated component governs the measurement system.
Bench repair and component checks
The DC millivolt range is useful for small signal checks, while resistance, diode and capacitance functions help narrow down faults on isolated electronic assemblies. The 10 MΩ-class voltage input reduces loading in many circuits. The audible continuity function is practical for checking isolated wiring and connectors. Follow the manufacturer’s limitations; do not perform resistance or capacitance checks on energized circuits.
When to select a different instrument
For non-sinusoidal AC loads such as many drive outputs and electronic power supplies, choose an appropriate True RMS meter; confirm bandwidth and any drive-specific filter requirements. The 77 IV is not a clamp meter, insulation resistance tester, thermometer or waveform recorder. MIN MAX AVG is not a substitute for a high-speed oscilloscope. Do not use AutoHOLD to prove that a circuit is de-energized. Current measurement requires correct fused terminals and circuit isolation before connections; never connect current inputs across a voltage source.
Compare digital multimeters
Explore Fluke instruments
Frequently asked questions
1. Is the Fluke 77 IV a True RMS multimeter?
No. Its AC measurement is average-responding and RMS-indicating for sinusoidal signals. For distorted AC waveforms, choose an appropriately rated True RMS instrument and check its bandwidth.
2. Can it measure 1000 V in every installation?
No. Its rating is CAT III 1000 V and CAT IV 600 V. The category, voltage, frequency and accessory ratings must all suit the circuit. The maximum terminal-to-earth voltage is 1000 V, not a blanket permission for every test.
3. Does the Fluke 77 IV measure 20 A?
The specified current range ends at 10 A. The separate mA input permits a 600 mA overload for up to 2 minutes, followed by 10 minutes of rest. Fluke allows a 20 A overload for no more than 30 seconds followed by 10 minutes of rest, without specified accuracy above 10 A. Select a suitable current clamp or other rated instrument for routine higher-current work.
4. Can the 77 IV check capacitors and diodes?
Yes. It supports capacitance up to 9,999 µF and diode testing up to 2.400 V. Discharge capacitors safely and isolate the circuit before resistance, continuity, diode or capacitance measurements.
5. Does it replace the older Fluke 77?
Fluke identifies the 77 IV as the replacement for the original 77. Check the required accuracy, safety category, measurement functions and accessories before replacing an older meter in an approved instrument list.
6. What comes with the Fluke 77 IV?
Fluke’s standard configuration includes the meter, a pair of test leads, an installed 9 V battery and user documentation. The optional TPAK hanger is not part of that standard configuration. Confirm the actual supplied pack and whether a calibration certificate is included before ordering.
7. What warranty applies to the Fluke 77 IV?
Fluke describes a limited lifetime warranty for eligible original purchasers under its manufacturer terms. Confirm the seller’s warranty coverage, purchase-channel eligibility and any calibration documentation requirements before placing an institutional order.
8. Can I order multiple Fluke 77 IV meters for a Punjab facility?
Yes. Indus MegaMart’s ordering policy accepts payment even when requested quantity exceeds available stock. Confirm the current selling unit, GST-inclusive total and delivery to your Punjab pincode before completing the order.
Buy Fluke 77 IV for your Punjab requirement
Choose the Fluke 77 IV if its average-responding AC functions and stated measurement limits match your work. Review the current offer, confirm quantity and delivery details, and proceed to the exact product listing.
Buy Fluke 77 IV Digital Multimeter