Buy Pilz 751126 PNOZ s6.1 C Safety Relay 24V DC 3NO 1NC in Patiala
For a Patiala-bound control-panel order, choose Pilz 751126 when the specified device is the 24 V DC PNOZ s6.1 C with plug-in spring-loaded terminals. This standalone PNOZsigma safety relay monitors simultaneous operation of two pushbuttons under Type IIIA requirements. It provides three normally open safety contacts, one normally closed auxiliary contact and one semiconductor status output. It is intended for low-risk two-hand applications identified by a risk assessment, not press controllers. The manufacturer packaging unit is one relay; confirm the selling unit on your order before checkout.
Check the current GST-inclusive price and tax breakdown, select the exact model and required quantity, and enter your Patiala delivery pincode on the product listing. For a replacement, match the order number on the existing device rather than relying on the 3NO 1NC description alone.
Buy now — Pilz 751126 PNOZ s6.1 C
Technical specifications of Pilz 751126
|
Parameter |
Specification |
|
Model/order number |
PNOZ s6.1 C / 751126 |
|
Product range/function |
PNOZsigma standalone; two-hand Type IIIA (EN ISO 13851) |
|
GTIN |
4046548045901 |
|
Power supply/consumption |
24 V DC (−15% / +10%); 3.5 W |
|
Inputs |
2; one NO contact per two-hand pushbutton |
|
Safety outputs |
3 instantaneous, positively guided NO contacts |
|
Auxiliary outputs |
1 instantaneous NC; 1 semiconductor, 24 V DC / 20 mA; non-safety |
|
Simultaneity/recovery |
Maximum 0.5 s; 250 ms recovery |
|
De-energisation response |
NO 40 ms; NC 50 ms (not whole-machine stopping time) |
|
Safety contact ratings |
AC-1: 6 A at 240 V AC; DC-1: 6 A at 24 V DC; AC-15: 5 A at 230 V AC; DC-13: 5 A at 24 V DC, 6 cycles/min |
|
Multiple contacts |
6 A per contact thermal rating with 1, 2 or 3 contacts loaded at DC supply, AC-1/DC-1 conditions; observe load/service life limits |
|
Connection / mounting |
Plug-in spring-loaded terminals; 35 mm DIN rail |
|
Conductor specification |
Flexible 0.2–2.5 mm² with/without ferrule; 2 terminal points per connection; 9 mm stripping length |
|
Dimensions / net mass |
100 × 22.5 × 120 mm (H × W × D); 185 g |
|
Ambient / protection |
−10 to +55 °C; no condensation; housing IP40, terminals IP20; cabinet at least IP54 |
|
OEM packaging |
1 relay per manufacturer packaging unit |
Selecting the relay for two-hand control or guard circuits
In a two-hand station, both controls must be operated within 0.5 seconds. Releasing either interrupts the enable command; both must be released before a fresh simultaneous operation can re-enable the outputs. The relay is only a component of the safety function; safe stopping distance, pushbutton placement and the machine’s complete stopping time must be validated by qualified personnel.
The two-hand function has PL c, Category 1, SIL 1 characteristics. The manufacturer also describes emergency-stop and safety-gate applications with PL e, Category 4, SIL 3 component characteristics under the prescribed conditions. These are not interchangeable safety ratings. The automatic-start arrangement for gate or E-stop applications requires external measures against unexpected restart. Do not use the NC or semiconductor outputs as safety contacts.
Contact load and feedback-loop checks
Compare contactor coil current and switching duty with the relevant AC-15 or DC-13 limit, rather than assuming a universal 6 A load. The 6 A thermal rating is for the stated AC-1/DC-1 conditions; apply the manufacturer’s service-life curves, fuse protection and suppression requirements. Feedback-loop monitoring can supervise external contactors in the approved design, but the relay does not detect shorts or cross-shorts within the feedback loop itself. The designer must consider suitable protective measures and validate the circuit.
Spring-terminal fit, replacement and expansion
The C variant fits a 22.5 mm-wide position on a 35 mm DIN rail. Allow for its 100 mm height, cable clearance and an IP54 or better control cabinet. The spring terminals accept the specified flexible conductor range. Status LEDs show supply, input channels, output, feedback and fault. Check the full Pilz manual and actual panel wiring before commissioning. One compatible PNOZsigma contact expansion module can be connected as specified by Pilz; do not assume independent additional safety functions.
Order number |
Supply |
Connection |
|
751126 (this item) |
24 V DC |
Spring-loaded |
|
750126 |
24 V DC |
Screw |
|
751156 |
48–240 V AC/DC |
Spring-loaded |
|
750156 |
48–240 V AC/DC |
Screw |
PNOZ s6 models are Type IIIC two-hand devices, while s6.1 models are Type IIIA. Select by risk assessment as well as terminal style, supply and contact rating. The wide-range s6.1 variants have different load limits. For spring terminal spares, Pilz lists 751004. Confirm whether additional accessories are needed before ordering.
Explore Pilz products
Compare safety relays
Ordering and delivery for Patiala
Whether buying a replacement or several relays for a panel build, enter the receiving site’s pincode and check delivery eligibility. Indus MegaMart accepts orders and payments even if the requested quantity exceeds stock or stock is zero. For serviceable pincodes, delivery is within 7 days when the available stock covers the order, and within 7–14 days when the order exceeds available stock, including zero stock. Confirm the selling unit, product condition and applicable warranty/return terms before payment. Generated purchase invoices contain the company GST number.
Frequently asked questions
1. Can I replace 750126 with 751126?
Both are 24 V DC S6.1 Type IIIA units, but 750126 has plug-in screw terminals and 751126 has plug-in spring-loaded terminals. Confirm terminal blocks, wiring, panel clearance, contacts and the validated safety function before substitution.
2. Is the NC contact a fourth safety output?
No. The three NO contacts are safety contacts. The NC auxiliary contact and semiconductor signalling output must not be used in a safety circuit.
3. Can I use the PNOZ s6.1 C for a press or a Type IIIC two-hand station?
No for press controllers. The two-hand function is Type IIIA, PL c, Category 1, SIL 1. If the risk assessment requires Type IIIC, select and validate a suitable alternative rather than assuming the same contact count makes it interchangeable.
4. Which replacement terminal set fits this relay?
Pilz lists the 751004 spring-loaded terminal set for its 22.5 mm unit. Confirm the exact spare and terminal mapping; the separately listed 750010 terminator plugs are not replacement terminals.
5. Can I order a quantity above the available stock for Patiala?
Yes. Indus MegaMart accepts orders and payment even when stock is insufficient or zero. For a serviceable delivery pincode, the order-quantity policy is within 7 days when available stock covers the order, or 7–14 days when it does not.
6. How do I confirm price and GST for a purchase order?
Open the exact 751126 product listing for the current GST-inclusive price, tax breakdown, quantity and delivery check. Confirm the selling unit, product condition and any required warranty or return terms before issuing a purchase order. Generated purchase invoices include the company GST number.
Ready to purchase the spring-terminal 24 V DC variant? Open the exact product listing to review price, quantity and delivery for your Patiala destination.