Fluke 87V MAX True RMS Digital Multimeter (IP67 Rated) in Navi Mumbai
Buy the Fluke 87V MAX from Indus MegaMart for electrical maintenance in Navi Mumbai where dust, moisture and rough handling are important considerations. This handheld industrial meter combines True RMS AC measurements, an IP67 enclosure and a selectable drive filter. It is designed for technicians maintaining motors, pumps and electrical control equipment. Review the current price, GST breakup and selling quantity on the exact product listing and check delivery using your Navi Mumbai pincode.
Buy Fluke 87V MAX IP67 Multimeter
Technical specifications
|
Parameter |
Fluke specification |
|
Voltage AC/DC |
1,000 V maximum |
|
Current AC/DC |
10 A; 20 A for 30 seconds only under manual conditions |
|
Resistance |
50 MΩ |
|
Capacitance |
9,999 µF |
|
Frequency |
Up to 200 kHz |
|
Temperature, meter |
−200 to +1,090 °C, excluding probe |
|
Supplied probe |
−40 to +260 °C |
|
Display |
6,000 counts; 19,999 high-resolution mode |
|
Conductance |
60 nS |
|
Diode test |
2 V range |
|
Safety |
CAT III 1000 V / CAT IV 600 V |
|
Enclosure |
IP67 (IEC 60529) |
|
Drop test |
4 m |
|
Operating temperature |
−15 to +55 °C; −40 °C for 20 minutes when taken from 20 °C |
|
Dimensions with holster |
60 × 101 × 215 mm |
|
Weight with holster |
698.5 g |
|
Power |
3 AA batteries; 800 hours typical without backlight |
|
Diagnostics |
Low-pass filter, Min/Max/Avg, 250 µs peak capture, Input Alert |
Basic DC voltage accuracy is ±(0.05% + 1 count) under specified conditions. Consult the manufacturer manual for range-specific accuracy and restrictions. Use the lowest applicable safety rating of the meter, leads and accessories.
Why select the 87V MAX for field maintenance?
Dust, moisture and rough handling
A sealed enclosure and protective holster suit demanding maintenance environments. The 4-metre drop test describes tested durability, not a guarantee against damage. Inspect the instrument and seals before use; IP67 does not make energized wet work safe. Backlit buttons and a two-level display backlight improve readability in dim equipment rooms.
Motor drives and intermittent faults
True RMS AC measurement helps assess distorted waveforms within specified bandwidth and crest-factor limits. The dedicated low-pass filter is intended for VFD measurements. Min/Max/Avg and peak capture support troubleshooting fluctuating readings. Resistance, continuity, diode and capacitance measurements help assess components on safely isolated circuits.
Standard manufacturer package
The OEM configuration consists of the 87V MAX meter, TL175 TwistGuard test leads, AC175 alligator clips, 80BK-A temperature probe, removable holster with lead storage and three installed AA batteries. Confirm the seller’s package and sale quantity when placing your order; additional clamps and calibration documentation are not listed in the standard OEM package.
Fluke 87V MAX vs standard Fluke 87V
|
Feature |
87V MAX |
87V |
|
IP rating |
IP67 |
IP30 |
|
Drop test |
4 m |
3 m |
|
Typical battery life |
800 h |
400 h |
|
Backlit keypad |
Yes |
No |
|
Voltage/current limits |
1000 V / 10 A |
1000 V / 10 A |
Choose the MAX when environmental protection and field durability justify the upgrade. Both meters offer True RMS AC and drive measurement capability. Neither replaces a dedicated insulation tester or power-quality analyzer.
Explore digital multimeters
Browse Fluke instruments
Test and measurement instruments
Price, GST and delivery in Navi Mumbai
Check the exact product page for the current price, GST breakup, stock and selling quantity. Enter the destination pincode to check serviceability for your maintenance facility or project address. Purchase invoices contain Indus MegaMart’s GST number. Confirm any calibration, warranty or return requirements before payment.
Orders and payments are accepted irrespective of available stock. Delivery is within 7 days for quantities within available stock and within 7–14 days for quantities exceeding available stock, including zero-stock orders, subject to destination serviceability.
Frequently asked questions
1. Is IP67 the same as intrinsic safety?
No. IP67 describes enclosure protection from dust and temporary immersion under test conditions. It does not establish approval for explosive atmospheres or permit live measurements underwater.
2. Does the 87V MAX work on variable-frequency drives?
Yes. It has a selectable low-pass filter for drive voltage and frequency measurements. Follow the Fluke manual and applicable ratings for the complete measurement setup.
3. Can it measure motor current above 10 A?
The normal direct current measurement limit is 10 A. The 20 A short-duration rating is subject to the manual. For higher currents, select a suitably rated clamp meter or compatible current accessory.
4. Can the included probe measure 1,090 °C?
No. The supplied 80BK-A probe is rated from −40 to +260 °C. The wider meter temperature range requires a suitable separate probe.
5. What is the warranty?
Fluke lists a limited lifetime warranty for the meter. Confirm the applicable seller and accessory warranty terms before ordering.
6. Can I order if stock is insufficient?
Yes. Orders and payment are accepted even when stock is zero. Delivery is within 7–14 days when ordered quantity exceeds available stock, subject to destination serviceability.
Order the Fluke 87V MAX for Navi Mumbai
Review the exact model, selling quantity and current offer, then proceed to order for your Navi Mumbai delivery address.