Pilz PNOZ e1vp C 784131 Electronic Safety Relay in Mumbai
The Pilz PNOZ e1vp C, manufacturer part number 784131, is a PNOZelog electronic safety relay for suitable machine-safety monitoring applications. Pilz describes a 24 V DC nominal supply, one instantaneous and one delayed semiconductor safety output, an auxiliary semiconductor output, and plug-in spring-loaded terminals. It supports specified emergency-stop and safety-gate monitoring functions when integrated and validated as part of an appropriate safety system.
For purchasing in Mumbai, review the exact Pilz PNOZ e1vp C 784131 product listing at Indus MegaMart. Check the exact part number, item condition, genuine remaining stock, applicable GST and delivery serviceability for your pincode before ordering. Pilz identifies this model as no longer available from the manufacturer, so any third-party supply requires particular care with provenance and availability.
Confirm the Exact 784131 Variant Before Buying
The manufacturer's complete designation is PNOZ e1vp C 10/24VDC 1so 1so t. The wording 10/24VDC is part of the model designation; it should not be read as a verified 10–24 V DC continuous supply range. Pilz states the device's nominal operating supply is 24 V DC. The delayed safety-output setting is selected from specified values up to 10 seconds, and the intended timing and stop function must follow the machine's validated safety design.
The letter C matters: 784131 uses plug-in spring-loaded terminals. The similarly named Pilz 774131 has plug-in screw terminals. A matching family name is not enough to prove a drop-in replacement. Verify terminal configuration, existing drawings, wiring, safety outputs and installed mounting arrangement.
Product Specifications
|
Attribute |
Detail |
|
Manufacturer |
Pilz |
|
Product family |
PNOZelog |
|
Exact part number |
784131 |
|
Manufacturer designation |
PNOZ e1vp C 10/24VDC 1so 1so t |
|
Nominal supply voltage |
24 V DC |
|
Safety outputs |
2 semiconductor safety outputs: 1 instantaneous and 1 delayed |
|
Other outputs |
1 auxiliary semiconductor output; 2 test pulse outputs |
|
Inputs |
1- or 2-channel, subject to approved safety-circuit design |
|
Start configurations |
Automatic or monitored start, as specified in the manual |
|
Selectable delay |
0, 0.15, 0.5, 1, 2, 3, 5, 7 or 10 seconds |
|
Terminal connection |
Plug-in spring-loaded |
|
Dimensions (H × W × D) |
101 × 22.5 × 121 mm |
|
Housing protection |
IP40 |
|
Ambient temperature |
-10 °C to +55 °C |
|
Individual packaging quantity |
1 module |
|
Manufacturer lifecycle |
No longer available from Pilz; confirm stock or approved successor |
What the Instantaneous and Delayed Outputs Mean
The module offers two electronic safety outputs with different switching behaviour: one instantaneous and one with an adjustable delay-on-de-energisation function. The delay is not a general-purpose countdown timer and does not independently certify a safe stopping distance. The permissible function, timing and wiring depend on the machine risk assessment, the protective-device arrangement, safety logic and the full Pilz operating manual.
It is not appropriate to assume that the two safety outputs are dry relay contacts or that they can be wired directly in place of an electromechanical contact output. Confirm the load type and electrical interface in the design documentation before procurement or replacement.
Typical Application Considerations
Pilz identifies application options including E-STOP monitoring, safety-gate monitoring, feedback-loop monitoring and suitable linked safety functions. A qualified machine-safety professional must confirm the exact wiring, channel selection, restart behaviour, output loading and achieved safety performance. Purchasing a safety relay with the right nominal voltage alone does not validate the overall safety circuit.
Manufacturer Availability and Replacement Planning
Pilz currently marks 784131 as no longer available. Indus MegaMart buyers should request a written check of available units, authentic manufacturer markings, item condition, packaging, documentation and sale terms. If the exact part cannot be supplied, ask Pilz technical support and a qualified safety engineer to identify and validate an appropriate successor; 784131 and 774131 should not be treated as automatically interchangeable.
Ordering the Pilz 784131 in Mumbai
Check the national product detail page — https://www.indusmegamart.com/safety-relays/pilz-pnoz-e1vp-c-electronic-safety-relay-1024v-dc-1so-1so-784131-supplier for the live order offer, tax details, quantity and delivery response to your Mumbai pincode. Do not interpret a catalogue listing or a preliminary delivery indication as confirmed physical inventory. For plant maintenance or planned shutdowns, provide the exact 784131 part number, required quantity, application documentation requirements, site pincode and GST-invoicing information when asking for a quotation. Confirm actual dispatch availability before scheduling installation.
Frequently Asked Questions
1. What is the exact Pilz part number for PNOZ e1vp C?
The exact part number is 784131. The full designation is PNOZ e1vp C 10/24VDC 1so 1so t.
2. Is the operating voltage 10–24 V DC?
No such continuous supply range should be inferred from the model name. Pilz's technical specifications state a nominal 24 V DC supply. Follow the OEM manual for permitted tolerances and wiring.
3. How many safety outputs does 784131 have?
It has two semiconductor safety outputs, comprising one instantaneous and one delayed output. There is also an auxiliary semiconductor output.
4. Does the module have an adjustable safety delay?
Yes. Pilz lists selectable timing choices from 0 to 10 seconds, including intermediate settings. A qualified engineer must select and validate the delay for the actual safety function.
5. Are the terminals screw or spring-loaded?
784131 uses plug-in spring-loaded terminals. The related 774131 variant uses screw terminals.
6. Is this a mechanical relay with dry contacts?
No. Pilz identifies electronic semiconductor safety outputs. Check the exact load and interface requirements; do not substitute the module for dry-contact relays without engineering approval.
7. Can it be used for emergency-stop or safety-gate monitoring?
Pilz identifies these among its supported application areas. The complete safety function must still be designed, wired, commissioned and validated by competent personnel under the applicable machine-safety requirements.
8. Is Pilz 784131 still in production?
Pilz currently states that the product is no longer available from the manufacturer. Verify any remaining genuine stock and seek official guidance about successors if required.
9. Can Pilz 774131 directly replace 784131?
Do not assume so. The terminal systems differ, and compatibility must be assessed against the full approved machine design, wiring and required safety performance.
10. How do I confirm the current Mumbai price and delivery?
Use the Indus MegaMart product listing and request confirmation of genuine available stock, price, GST, seller terms and delivery by Mumbai pincode. For urgent maintenance, obtain written availability confirmation before committing to a shutdown plan.
Check the Exact Pilz 784131 Offer
View Pilz PNOZ e1vp C 784131 at Indus MegaMart to confirm the 24 V DC model, electronic safety outputs, spring-loaded terminals, item condition, availability, GST and Mumbai delivery options. If 784131 is unavailable, request manufacturer-backed replacement guidance rather than choosing an unverified substitute.