Order the Pilz PNOZ X2.4V, manufacturer part number 774517, from Indus MegaMart for your Maheshtala industrial control panel or maintenance requirement. This 24 V DC standalone safety relay has four normally open safety contacts with a fixed nominal one-second off-delay and one instantaneous semiconductor signalling output. It is intended for emergency-stop and safety-gate circuits where the validated stopping sequence calls for delayed contact release. If your bill of materials specifies this exact model, check the current price, selling quantity and delivery details before placing your order.
View price and buy Pilz 774517
Technical specifications of PNOZ X2.4V
|
Parameter |
Specification |
|
Brand/model/MPN |
Pilz/PNOZ X2.4V/774517 |
|
Product family |
PNOZ X standalone safety relay |
|
Supply |
24 V DC; −15%/+10%; 2 W |
|
Input configuration |
Single or dual channel; cross-short detection depends on configuration |
|
Safety outputs |
4 delayed normally open contacts; no dedicated instantaneous safety contact |
|
Off-delay |
Fixed nominal 1 s; −30%/+100%; delay can be disabled as documented |
|
Signal output |
Y12: 24 V DC, 50 mA, DC-12; non-safety |
|
Contact rating |
AC-1: 6 A at 240 V; DC-1: 6 A at 24 V; AC-15: 5 A at 230 V; DC-13: 5 A at 24 V (6 cycles/min) |
|
Concurrent loading |
AC-1/DC-1 thermal current per contact: 1/2/3/4 loaded = 6/5.5/4.6/4 A |
|
Start modes |
Automatic or manual; feedback loop supported |
|
Mounting / terminals |
35 mm DIN rail; fixed screw terminals; single flexible conductor 0.2–4 mm² |
|
Dimensions / net weight |
87 × 45 × 121 mm (H × W × D); 290 g |
|
Ambient / enclosure |
−10 to +55 °C; no condensation; IP40 housing, IP20 terminals, IP54 cabinet minimum |
|
Safety characteristic |
Delayed contacts: PL d, Category 3, SIL 2; complete function separately validated |
|
Manufacturer pack / GTIN |
1 per OEM packaging unit; GTIN 4046548011142 |
|
Approvals listed by Pilz |
CCC, CE, EAC, TÜV, UKCA |
When the fixed off-delay matters
When a monitored input opens, Y12 changes state without the intentional one-second contact delay. The four safety contacts release after the off-delay in the documented timed mode. This distinction is useful when the control design requires a drive stop command before the delayed safety contacts interrupt the downstream circuit. Y12 must never be relied upon as a safety circuit output.
The nominal delay is not a minimum guaranteed dwell time. The manufacturer specifies −30%/+100% timing accuracy and warns that a fault may cause earlier opening. Select a different safety solution if the application requires a minimum delay or a separate instantaneous safety contact. The machine’s actual stopping time, not the relay setting alone, determines whether the safety function is suitable.
Selection for emergency stops and guard doors
For a machine emergency-stop circuit, confirm whether delayed removal of power is appropriate to the assessed hazard. For guard monitoring, verify the switch type, channel architecture and restart behaviour. The relay supports automatic and manual starting; automatic restart must not be selected where it can expose personnel to unexpected movement. The input circuit can be configured for cross-short detection, but the start/feedback loop has separate limitations and requires suitable protective measures.
Panel builders and maintenance teams should check the 45 mm rail-space requirement, fixed terminal arrangement and thermal limits of the actual contact load. The 6 A resistive-load rating is not an allowance to switch every contact at 6 A simultaneously. External contactors or expansion modules may be used only where the complete circuit is approved for the required safety performance. Have qualified personnel carry out selection, installation and validation using the Pilz operating manual.
Compare the output arrangement before substituting
|
Model |
Safety contacts and delay |
Selection distinction |
|
PNOZ X2.4V 774517 |
4 delayed NO; fixed 1 s |
Four delayed contacts; no independent instantaneous safety contact |
|
PNOZ XV2 774504 |
2 instantaneous NO + 2 delayed NO; fixed 0.5 s |
Mixed output arrangement; different timing |
|
PNOZ XV2 774502 |
2 instantaneous NO + 2 delayed NO; adjustable 0.1–3 s |
Mixed outputs and selectable delay |
These are selection comparisons, not approved drop-in replacements. For other configurations, browse the safety relay range or explore Pilz products.
Price, order quantity and delivery in Maheshtala
Check the exact product listing for its current GST-inclusive price, selling unit and order quantity. Pilz specifies one relay per manufacturer packaging unit; verify the Indus MegaMart selling unit when preparing a purchase order. Enter your Maheshtala delivery pincode on the product listing to check fulfilment details. For a planned maintenance shutdown, review the delivery timeline against your actual required quantity before payment.
Indus MegaMart’s standard ordering policy accepts payment and orders even when available stock is insufficient. The standard timeline is within 7 days when the ordered quantity is within available stock, and 7–14 days when the requested quantity exceeds stock, including zero available stock. Confirm the actual delivery commitment for this item before ordering. Single-unit and bulk enquiries can be coordinated through the exact product listing; verify warranty and return terms before purchase.
Frequently asked questions
1. Is the 1-second delay adjustable?
No. 774517 has a fixed nominal one-second off-delay, not an adjustable timing range. Pilz documents a mode that switches the delay off; use the manual for the permitted configuration.
2. Does Y12 provide an instantaneous safety contact?
No. Y12 is a semiconductor signalling output, not a safety-rated output. Do not use it as an emergency-stop safety channel.
3. Can I use all four contacts at 6 A each?
No. The simultaneous-load limit for four contacts is 4 A per contact under the stated AC-1/DC-1 thermal conditions. Inductive loads and switching frequency require separate checks.
4. Can the relay guarantee a minimum one-second stopping delay?
No. The specified timing tolerance is −30%/+100%, and faults can cause earlier opening. Do not select it for a safety function that requires a guaranteed minimum delay.
5. Can I replace another PNOZ X or XV relay with 774517?
Only after a qualified assessment of the exact output functions, supply, delay, reset, terminals and required safety performance. Similar housings or the same supply voltage do not establish interchangeability.
6. Can it monitor a light curtain directly?
The manufacturer identifies emergency-stop pushbuttons and safety gates as intended applications. Do not assume direct compatibility with light-curtain OSSD outputs; verify the interface and use an approved solution.
7. Can I order if available stock is zero?
Yes. Indus MegaMart accepts orders and payment even when the requested quantity exceeds stock. Confirm the applicable fulfilment timeline and Maheshtala delivery pincode before ordering.
8. Will I receive a GST invoice?
Purchase invoices contain Indus MegaMart’s GST number. Review the applicable GST amount, selling unit and order total before payment.
Choose the exact 774517 model for your approved safety circuit and confirm the order quantity and Maheshtala delivery details.
Buy Pilz PNOZ X2.4V 24VDC (774517)