Buy Pilz PNOZ s5 C 48-240 V AC/DC Time-Delay Safety Relay (751135) in Lucknow
For machine-control panels that need both immediate and delayed safety switching, the Pilz PNOZ s5 C (751135) combines two instantaneous normally-open safety contacts with two off-delay normally-open safety contacts. The 48–240 V AC/DC supply and plug-in spring-loaded terminals distinguish this model from the 24 V DC versions and the screw-terminal 750135. Lucknow maintenance teams, panel builders and procurement departments can use the exact part number to review the product offer and order the correct relay.
View current offer for Pilz 751135
Ordering the 751135 for delivery in Lucknow
Review the current price, GST basis, selling unit and required quantity on the exact product listing before payment. For your Lucknow delivery address, confirm pincode serviceability and the order total. Indus MegaMart accepts orders and payment even when the quantity requested is greater than available stock, including zero stock. Under its delivery policy, quantities within available stock are delivered within 7 days; quantities exceeding stock are delivered within 7–14 days. Purchase invoices carry the company’s GST number.
Technical specifications
|
Parameter |
Specification |
|
Brand/family |
Pilz / PNOZsigma |
|
Model / MPN |
PNOZ s5 C / 751135 |
|
GTIN |
4046548025460 |
|
Supply |
48–240 V AC/DC; 50–60 Hz AC |
|
Power consumption |
8 VA AC / 4 W DC |
|
Safety inputs |
2; single- or dual-channel configurations |
|
Safety contacts |
2 instantaneous NO + 2 off-delay NO |
|
Adjustable off-delay |
0.04–300 s |
|
Signal output |
1 semiconductor output (non-safety signalling) |
|
Start |
Automatic, manual or monitored start |
|
Terminals |
Plug-in spring-loaded terminals |
|
Size (H × W × D) |
100 × 22.5 × 120 mm |
|
Weight |
250 g |
|
Operating temperature |
−10 to +55 °C; no condensation |
|
Safety contact ratings |
AC-1: 6 A at 240 V AC; DC-1: 6 A at 24 V DC; AC-15: 3 A at 230 V AC; DC-13: 4 A at 24 V DC (6 cycles/min) |
|
Safety characteristics |
Up to PL e / Cat. 4 / SIL 3, subject to validated safety function |
Where the timed safety contacts are useful
The 751135 is suited to emergency-stop and safety-gate monitoring in a validated machine safety circuit. Its two immediate contacts can initiate a safety response while the two off-delay contacts allow a separately timed de-energisation stage. This is useful where the risk assessment requires a controlled stop before final isolation. The delay is not proof of standstill; a qualified engineer must determine and validate the stopping sequence and the total reaction time for the machine. Do not use the semiconductor signal output as an additional safety contact.
Check supply, inputs and replacement compatibility
The 48–240 V AC/DC rating refers to the relay supply, not to every input or output circuit. The manual specifies 24 V DC for the input, start and feedback circuits. Choose the wiring and restart arrangement according to the risk assessment; automatic restart must not create unexpected machine movement. The direct electronic light-grid/safety-switch connection shown in the manual is restricted to 24 V DC supply variants, so do not assume that the 751135 accepts the same OSSD arrangement. Confirm the sensor interface and suitable safety relay with the machine designer.
Check the label on the installed relay before ordering. Part 750135 has the same nominal wide-voltage supply but screw terminals; 751105 is the 24 V DC spring-terminal version, and 751185 is its coated 24 V DC counterpart. A similar housing or contact count does not make these variants interchangeable. Verify the power supply, connector type, contact utilisation category, timing and complete safety-function design before any substitution.
For other models, explore Pilz products and compare safety relays in the electrical and industrial automation range.
Frequently asked questions
1. What does 2 n/o 2 n/o t mean on the PNOZ s5 C?
It identifies two immediate normally-open safety contacts and two normally-open safety contacts with delay on de-energisation. The delayed pair opens after the selected interval during a safety demand, rather than acting as a delay-on-energisation timer.
2. Can I use 751135 on a 24 V DC supply?
No. Its nominal supply range starts at 48 V AC/DC. For a 24 V DC supply, evaluate the 751105 spring-terminal variant against the machine requirements.
3. Is the output current always 6 A?
No. The 6 A value applies to AC-1 and DC-1 under the specified conditions; AC-15 and DC-13 control loads have different limits. Check the manufacturer’s load ratings, protection and switching duty before selection.
4. Can the delay be set to prove that a motor has stopped?
No. The relay supplies a timed safety switching function, not a measured standstill signal. The actual stopping process must be validated for the intended application.
5. Does the relay alone guarantee PL e or SIL 3?
No. The manufacturer lists those safety characteristics for the device, but the achieved performance level or SIL depends on the complete safety function, operating mode and validation.
6. What should procurement confirm about the pack and warranty?
Confirm the listed selling unit, quantity, product condition, included terminals and applicable warranty or return terms for 751135 before placing the order.
7. Can I order more than the available stock?
Yes. Orders and payment remain accepted even if available stock is zero. The applicable delivery window for a quantity above available stock is 7–14 days, subject to confirming the destination serviceability.