Order the Pilz PNOZ XV2P C safety relay, manufacturer part number 787500, for industrial procurement in Kolkata through Indus MegaMart. This 24 V DC standalone safety relay combines two instantaneous normally open safety contacts with two additional delay-on-de-energisation N/O safety contacts. Its selectable delay range is 0.1–30 seconds. Check the exact model, live price, GST basis and delivery availability on the product listing before placing your order.
Order Pilz 787500 for Kolkata delivery
The Indus MegaMart product page provides the current offer, order quantity control, pincode delivery check and Add to Cart route for this specific relay. For plant maintenance or a machine-build project, confirm the complete model code PNOZ XV2P C, order number 787500 and required quantity rather than ordering a different XV2P timing or terminal variant.
Key technical specifications
|
Specification |
Detail |
|
Brand / family |
Pilz / PNOZ X |
|
Exact model / MPN |
PNOZ XV2P C 30/24VDC — 787500 |
|
Supply |
24 V DC; 4.5 W |
|
Safety contacts |
2 instantaneous N/O + 2 delay-on-de-energisation N/O |
|
Selectable delay |
0.1–30 s, with 12 OEM-defined settings |
|
Start modes |
Automatic or monitored start |
|
Input wiring |
One- or two-channel; shorts-across-contacts monitoring when correctly wired |
|
Connections |
Plug-in spring-loaded terminals |
|
Housing dimensions |
101 mm high × 45 mm wide × 121 mm deep |
|
Mounting / ambient |
DIN rail; -10 to +55 °C |
|
Contact rating |
Up to 8 A at the specified AC1/DC1 operating conditions; verify actual utilisation category and protection |
|
Manufacturer GTIN |
4046548008302 |
What the two output pairs do
Safety contacts 13–14 and 23–24 switch off immediately when the relevant safety input opens. Contacts 37–38 and 47–48 are the separate delayed N/O safety outputs; they open after the selected delay has elapsed. The timed outputs are delay-on-de-energisation contacts, not a substitute for a correctly engineered motor stopping or guard-locking system.
Select the correct delay range
Model 787500 has selectable delay settings from 0.1 to 30 seconds. The timing choice must be based on the machine risk assessment, stopping performance and the instructions in the Pilz operating manual. A timed safety output does not, by itself, prove that all hazardous motion has stopped; braking, standstill detection and gate-release functions require the appropriate system design.
Model and terminal checks
The “C” suffix matters: Pilz 787500 is the spring-terminal version. Pilz 777500 uses plug-in screw terminals for the same 30-second selectable family, while 787502 is a spring-terminal version with the shorter 0.1–3-second selectable range. These order numbers should not be treated as automatically interchangeable during panel replacement.
Typical safety applications and limitations
The PNOZ XV2P C can monitor E-STOP switches and safety gates using a correctly configured single- or dual-channel input circuit. It supports automatic or monitored start modes and can form part of a safety architecture that needs separate instantaneous and delayed contact paths. Engineers must check the full safety function, external contactors, contact protection, wiring, required performance level and enclosure conditions against the official manual. Its IP40 housing is not a claim of outdoor or washdown suitability.
Ordering and delivery in Kolkata
Choose the required quantity and check the destination pincode on the exact product page. Under Indus MegaMart’s ordering policy, orders and payment can be accepted even where available stock is below the requested quantity. When ordered quantity is within available stock, the stated delivery window is within 7 days; when it exceeds available stock, including zero stock, the window is within 7–14 days. Delivery applicability and final checkout details should be confirmed for the Kolkata destination.
Frequently asked questions
1. Does Pilz 787500 have four immediate safety outputs?
No. It provides two instantaneous N/O safety contacts and two separate N/O contacts with delay-on-de-energisation. Their switching behaviour is not identical.
2. What is the selectable time range of PNOZ XV2P C 787500?
The 787500 model has a selectable delay range from 0.1 to 30 seconds, using the manufacturer-defined settings.
3. Are 787500 and 777500 the same terminal version?
No. The 787500 C variant uses plug-in spring-loaded terminals; the 777500 variant uses plug-in screw terminals.
4. Can I substitute Pilz 787502 for 787500?
Not without checking the design: 787502 has a shorter 0.1–3-second selectable range. Verify the required time and all wiring and safety specifications.
5. Can this relay confirm a machine has stopped before a safety gate unlocks?
Not by itself. Delayed relay contacts do not independently verify standstill; use a suitable, validated safety architecture for machine stopping and access control.
6. Can I order this safety relay if available stock is lower than my requirement?
Indus MegaMart’s order policy allows placing orders and making payment despite insufficient displayed stock. The delivery window depends on the stock-to-order quantity relationship.
7. How do I check the current price and delivery for Kolkata?
Open the exact 787500 Indus MegaMart product listing, review its current GST-inclusive price and quantity selection, then enter the destination pincode to check delivery details.
Buy Pilz PNOZ XV2P C 787500
Ready to source the exact 24 V DC, 0.1–30 s selectable-delay model? Check the current price, select your quantity and proceed to purchase Pilz PNOZ XV2P C 787500 on Indus MegaMart.
Buy Pilz 787500 — exact product page