For control-panel builders, maintenance teams and procurement buyers in Kerala, Pilz 750134 is the PNOZsigma PNOZ s4 standalone safety relay for emergency-stop and safety-gate monitoring. This version accepts a 48–240 V AC/DC supply and provides three instantaneous normally open safety contacts, one normally closed auxiliary contact and a semiconductor status output. Its removable screw terminals and 22.5 mm width make it a practical option where the existing circuit calls for this exact model.
Before purchasing, compare the part number on your bill of materials or existing unit. Check the current selling price, applicable GST, selling quantity and delivery availability for your Kerala PIN code with Indus MegaMart.
View Pilz 750134 price and order details
Technical specifications of Pilz PNOZ s4 750134
|
Parameter |
Specification |
|
Brand / family |
Pilz / PNOZsigma PNOZ s4 |
|
Manufacturer part number / GTIN |
750134 / 4046548025606 |
|
Rated supply voltage |
48–240 V AC/DC; AC 50–60 Hz |
|
Supply tolerance / consumption |
−15% / +10%; 5 VA AC, 2.5 W DC |
|
Inputs / start modes |
2 inputs; single- or dual-channel; automatic, manual or monitored start as configured |
|
Safety outputs |
3 NO, instantaneous, positively guided relay contacts |
|
Auxiliary / diagnostic outputs |
1 NC auxiliary; 1 semiconductor status output (24 V DC, 20 mA, DC-12); not safety outputs |
|
Safety-contact utilisation |
AC-1: 6 A at 240 V; DC-1: 6 A at 24 V; AC-15: 3 A at 230 V; DC-13: 4 A at 24 V (6 cycles/min) |
|
Thermal current |
6 A per contact with one or two loaded; 4.5 A per contact with three loaded (AC-1/DC-1 conditions) |
|
Connection / installation |
Plug-in screw terminals; 35 mm DIN rail; cabinet IP54 or better |
|
Dimensions (H × W × D) / net weight |
98 × 22.5 × 120 mm; 210 g |
|
Housing / ambient |
PC; housing IP40; −10 to +55 °C; no condensation |
|
E-stop de-energisation delay |
10 ms typical; 20 ms maximum (relay only) |
|
Component safety data |
PL e, Category 4; SIL 3 under specified conditions; complete function requires validation |
|
OEM packaging |
1 relay per manufacturer packaging unit; confirm seller selling unit separately |
What the wide-supply s4 relay can do
The relay monitors the safety input circuit and permits its safety contacts to close only when the configured input and start conditions are fulfilled. Its redundant internal design and monitoring features are intended for safety-related interruption. Use the three NO contacts for the approved safety circuit; reserve the NC auxiliary contact and the semiconductor output for non-safety indication or diagnostics. LEDs show power, input, output, reset and fault status.
Emergency-stop and guard-door circuit selection
Typical applications include fixed machinery with emergency-stop pushbuttons and guarded access points with suitable safety gate limit switches. Select the input-channel arrangement, cross-short detection and restart mode to suit the risk assessment. Single-channel wiring may lower the achieved safety level. The relay is a component of a protective circuit, not a complete machine stopping system or a general-purpose motor starter.
Contact ratings depend on the load
The 6 A headline value is not a universal switching current. As shown in the specification table, inductive control circuits have different utilisation limits, and loading all three contacts reduces their permitted thermal current. Check load type, voltage, current, protective devices and switching duty before approving a replacement.
Choose the correct supply and termination variant
The 750134 is the wide-supply screw-terminal version. The 750104 is the 24 V DC screw-terminal version, while the 751134 uses spring-loaded terminals with the wide supply range. Do not choose solely by the PNOZ s4 family name or the 3NO 1NC contact count. The manufacturer’s direct light-curtain or safety-switch connection using ESPE short detection applies only to its 24 V DC supply variants; do not assume that arrangement is supported by 750134.
Expansion and maintenance considerations
One compatible PNOZsigma contact expansion module may be connected using the specified connector. The wide-supply base unit requires the expansion module safety-contact thermal-current allowance to be limited to 70% of its stated value. For spare screw terminals, Pilz lists set 750004 as an optional accessory. Accessories are not represented as included in the seller’s package. Consult the applicable Pilz operating manual and have qualified personnel validate the complete safety function before commissioning or returning a machine to service.
Ordering and delivery for Kerala buyers
Indus MegaMart lists its office at Ajmeri Gate, New Kerala. For a project, scheduled maintenance or multiple-relay order, specify part number 750134, the required quantity, billing details and the delivery PIN code. Confirm the selling unit, current order total and fulfillment terms; office location does not indicate local stock or counter pickup.
Under Indus MegaMart’s ordering policy, quantities within available stock have a delivery period of up to 7 days. Quantities exceeding available stock, including when available stock is zero, can still be ordered and paid for, with delivery within 7–14 days. Check serviceability and confirm the applicable delivery period for your PIN code before purchase. Generated purchase invoices carry the company GST number.
Explore Pilz products
Compare other safety relays
Contact Indus MegaMart for order support
Frequently asked questions
1. Does 750134 work with 230 V AC?
Yes. Its rated supply covers 48–240 V AC/DC, so 230 V AC is within the stated range. The correct supply connection and protection must follow the manufacturer’s manual.
2. Is the 1NC output a fourth safety contact?
No. The three NO contacts are the safety outputs. The NC contact is auxiliary and the semiconductor output is also intended for non-safety signalling.
3. Can I replace 750104 with 750134?
Not without engineering verification. 750104 is a 24 V DC supply model, whereas 750134 is specified for 48–240 V AC/DC. Verify the circuit supply, ratings, sensor interface, start arrangement and safety assessment first.
4. Can all three safety contacts carry 6 A at once?
No. Under the specified AC-1/DC-1 thermal conditions, the manufacturer limits three simultaneously loaded contacts to 4.5 A per contact. Other utilisation categories, duty and protection requirements must also be checked.
5. Can this variant connect directly to a light curtain with electronic safety outputs?
Do not assume compatibility. The Pilz manual’s direct ESPE short-detection connection is specified for the 24 V DC supply variants. Have the exact sensor and interface assessed.
6. How many relays come in one pack?
Pilz lists one unit per manufacturer package for 750134. Confirm Indus MegaMart’s selling unit and any accessories before placing the order.
7. Can I order more units than the available stock?
Yes, the store’s order policy permits payment and ordering even when stock is insufficient or zero. The applicable delivery window is 7–14 days, subject to confirmation for your PIN code.
8. Where can I confirm warranty, returns and price?
Check the exact product offer and ask Indus MegaMart order support to confirm the selling quantity, GST, warranty and applicable return conditions before payment.
Order the exact Pilz 750134 safety relay
Confirm the 48–240 V AC/DC supply, plug-in screw terminals and required quantity, then continue to the product listing for the current offer and purchasing options.