Pilz PNOZ m ES 14DO Digital Output Module 772181 in Jalgaon
Order the Pilz PNOZ m ES 14DO (part number 772181) for a PNOZmulti 2 control system serving your Jalgaon facility or machine-building project. This expansion module provides 14 semiconductor digital outputs for standard, non-safety-related control functions. It is not a 14-channel safety-output module. Check the exact model, current price and order quantity on Indus MegaMart before purchasing, then confirm delivery eligibility with your destination pincode.
Order Pilz 772181 for Delivery in Jalgaon
On the Pilz 772181 product listing, review the displayed price and GST amount, select the required quantity and use the Add to Cart or Buy Now purchase route. Orders and payment are accepted even when the requested quantity exceeds the displayed available stock. Confirm the listed selling unit or pack with the seller before placing a project or replacement order.
For orders covered by available stock, the Indus MegaMart delivery policy states delivery within 7 days. If the ordered quantity exceeds available stock, including when stock is zero, the policy states delivery within 7–14 days. Use the product-page pincode check to review delivery details for your Jalgaon address.
View the exact product and order: View exact Pilz 772181 product listing
What the PNOZ m ES 14DO Module Does
PNOZ m ES 14DO expands the standard digital output capacity of a compatible PNOZmulti 2 configurable controller. The 14 positive-switching semiconductor outputs can be used for suitable non-safety control signals and permitted resistive, inductive or capacitive loads within the manufacturer’s stated ratings. The module receives its internal supply from the associated base unit and requires a separate 24 V DC supply for its output circuits.
The distinction between standard and safety-rated I/O matters: this module does not replace a certified safety-output expansion. Where a machine function requires a safety-rated output, the safety design must specify an appropriate Pilz safety module instead.
Pilz 772181 Technical Specifications
|
Specification |
Manufacturer-verified detail |
|
Manufacturer / exact model |
Pilz PNOZ m ES 14DO; MPN 772181; GTIN 4046548085129 |
|
Product class |
PNOZmulti 2 standard digital output expansion module |
|
Output channels |
14 positive-switching semiconductor outputs for non-safety applications |
|
Output power supply |
24 V DC (U2), tolerance −20% / +25% |
|
Internal module supply |
Supplied via compatible PNOZmulti 2 base unit |
|
Permitted load types |
Resistive, inductive and capacitive, subject to ratings and system design |
|
Terminals |
Plug-in screw or spring-loaded connections with applicable terminal accessory |
|
Size (H × W × D) |
101.4 × 22.5 × 120 mm |
|
Ambient operating temperature |
0 to +60 °C |
|
Enclosure protection |
IP20 housing; IP54 specified for mounting environment |
|
Mounting |
Horizontal, DIN rail 35 × 7.5 mm |
|
Net weight |
100 g |
Compatibility and Installation Checks
Check the PNOZmulti 2 configuration
Confirm the model of the existing PNOZmulti 2 base controller, the supported expansion arrangement and the configuration in Pilz PNOZmulti Configurator before ordering. PNOZ m ES 14DO is an expansion module, not a standalone controller. A matching part number and approved system design are more reliable than assuming interchangeability with every Pilz controller generation.
Confirm terminal accessories and panel conditions
Pilz lists plug-in screw-terminal set 750004 and spring-loaded terminal set 751004 as obligatory accessory options for this module. Confirm which terminal solution is specified for your installation and whether the selected merchant selling pack includes it. The 22.5 mm-wide unit mounts horizontally on a 35 × 7.5 mm DIN rail; its housing is IP20, while the manufacturer specifies an IP54 mounting environment.
Where Standard Digital Outputs Are Useful
In a suitable PNOZmulti 2 installation, the 14 standard outputs can help communicate non-safety machine states or perform standard control tasks—for example, indicator signals, status interfaces and auxiliary equipment commands. Actual connected loads must be selected against the relevant electrical ratings and system drawings. Emergency-stop chains, guard interlocks and other safety functions must use safety-rated elements specified by the safety engineer.
Select the Correct Output Module
Choose 772181 when the documented requirement is 14 standard semiconductor outputs. Do not select it solely because a listing calls it a “safety output module”. If the engineering specification calls for safety-rated output channels, compare the applicable Pilz PNOZmulti 2 safe-I/O family, such as an appropriately configured PNOZ m EF output module, and confirm its exact output count and required safety performance.
Questions Buyers Ask About Pilz PNOZ m ES 14DO
1. Does Pilz 772181 provide 14 safety-rated outputs?
No. It provides 14 semiconductor digital outputs for standard, non-safety-related applications. It should not be used as a direct substitute for a safety-rated output module.
2. Can PNOZ m ES 14DO operate on its own?
No. It is an expansion module for a compatible PNOZmulti 2 base-unit configuration.
3. What supply voltage is required?
The output supply U2 is 24 V DC, with the manufacturer’s stated tolerance of −20% to +25%. The module’s internal supply is provided through the base unit.
4. Are the screw or spring terminals included with the module?
Pilz identifies terminal sets 750004 and 751004 as applicable obligatory accessories. Confirm your chosen terminal type and the seller’s included-items list before ordering.
5. Can I place an order if the shown stock is lower than my quantity?
Yes. Indus MegaMart accepts orders and payment even when the available stock is insufficient or zero. Its policy states delivery within 7 days for quantities within stock and 7–14 days when stock is insufficient, subject to checking the delivery details for your address.
6. Will the price and GST information match the national product listing?
The current price and GST information are shown on the exact Indus MegaMart product page. Review them before payment, along with the selected quantity and selling unit.
7. What is the main difference between this module and a safe-output expansion?
The PNOZ m ES 14DO is for standard control outputs, whereas a safe-output expansion is selected for safety-related switching according to the machine’s safety architecture. Output count alone is not enough to establish interchangeability.
Buy Pilz PNOZ m ES 14DO 772181 from Indus MegaMart
For a Jalgaon-based panel build, retrofit or spare-part purchase, verify part number 772181, the required terminal accessories and your system configuration, then use the exact product listing to review the current price and complete your order.
Buy Now – Pilz PNOZ m ES 14DO (772181): View exact product & order