Fluke 15B+ Digital Multimeter in Jaisalmer
The Fluke 15B+ is a 4000-count handheld digital multimeter for electrical maintenance, commercial facility servicing and equipment troubleshooting. It combines AC/DC voltage ranges up to 1000 V, direct AC/DC current ranges up to 10 A, resistance, capacitance, continuity and diode testing in one battery-powered instrument. Its CAT III 600 V rating, white backlight and manual or automatic range selection make it a practical choice for trained technicians who need routine measurements rather than advanced data logging. If you are buying for a Jaisalmer workshop, maintenance team or project site, check the exact 15B+ listing, quantity, current price and delivery details before placing an order.
Buy Fluke 15B+ online for Jaisalmer delivery
Select Fluke 15B+ on the product page and review the current GST-inclusive price, the selling unit, quantity and delivery estimate for your pincode. Indus MegaMart purchase invoices contain the company GST number. For multi-meter procurement, confirm the required number of meters, package contents and any calibration or warranty documentation before finalizing the order.
View price and buy Fluke 15B+ Digital Multimeter
Indus MegaMart accepts orders and payment even if stock is insufficient or zero. Its delivery policy is within 7 days when the order quantity is within available stock, and 7–14 days for quantities beyond available stock, including zero stock. Check the applicable delivery estimate and serviceability for your Jaisalmer pincode before payment.
Measurement ranges and accuracy
The table lists full-scale range settings, corresponding resolution and manufacturer accuracy for model 15B+. The accuracy expression is ±(percentage of reading + indicated count of the least significant digit), under the stated calibration conditions (one year after calibration, 18–28 °C, 0–75% RH).
Function |
Range settings |
Resolution |
Accuracy |
|
AC volts (40–500 Hz) |
4.000 / 40.00 / 400.0 / 1000 V |
0.001 / 0.01 / 0.1 / 1 V |
1.0% + 3 |
|
DC volts |
4.000 / 40.00 / 400.0 / 1000 V |
0.001 / 0.01 / 0.1 / 1 V |
0.5% + 3 |
|
AC millivolts |
400.0 mV |
0.1 mV |
3.0% + 3 |
|
DC millivolts |
400.0 mV |
0.1 mV |
1.0% + 10 |
|
AC/DC µA |
400.0 / 4000 µA |
0.1 / 1 µA |
1.5% + 3 |
|
AC/DC mA |
40.00 / 400.0 mA |
0.01 / 0.1 mA |
1.5% + 3 |
|
AC/DC A |
4.000 / 10.00 A |
0.001 / 0.01 A |
1.5% + 3 |
|
Resistance |
400.0 Ω |
0.1 Ω |
0.5% + 3 |
|
Resistance |
4.000 / 40.00 / 400.0 kΩ; 4.000 MΩ |
0.001 / 0.01 / 0.1 kΩ; 0.001 MΩ |
0.5% + 2 |
|
Resistance |
40.00 MΩ |
0.01 MΩ |
1.5% + 3 |
|
Capacitance |
40.00 / 400.0 nF |
0.01 / 0.1 nF |
2% + 5 |
|
Capacitance |
4.000 / 40.00 / 400.0 / 1000 µF |
0.001 / 0.01 / 0.1 / 1 µF |
5% + 5 |
|
Diode |
2.000 V |
0.001 V |
10% |
AC current specifications apply at 40–400 Hz; AC readings are specified from 1% to 100% of range. Capacitance accuracy excludes lead capacitance and the measurement floor, which can reach 1.5 nF on the 40 nF range. Diode testing has a typical 2.0 V open-circuit voltage and short-circuit current below 0.6 mA. The continuity beeper operates below 70 Ω. A beeper indication alone does not prove that a conductor is safe or has the required low resistance.
Display, construction and operating specifications
|
Parameter |
Fluke 15B+ |
|
Display |
4000 counts, 3 updates/second, white backlight |
|
Range selection |
Auto and manual; Data Hold; low battery indication |
|
Power |
2 AA (IEC LR6); 500 hours minimum rated battery life |
|
Auto shutoff |
Meter: 20 minutes inactivity; backlight: 2 minutes inactivity |
|
Case / weight |
183 × 91 × 49.5 mm (H × W × L); 455 g |
|
Ingress / safety |
IP40; CAT III 600 V common rating; pollution degree 2 |
|
Current input protection |
440 mA and 11 A fast fuses, each 1000 V; specified replacements only |
|
Temperature |
Operating 0–40 °C; storage −30 to 60 °C |
|
Humidity |
≤90% RH at 10–30 °C; ≤75% at 30–40 °C; 40 MΩ range ≤80% and ≤70% respectively; non-condensing below 10 °C |
|
Altitude |
Operating 2000 m; storage 12,000 m |
|
Voltage input impedance |
V ranges >10 MΩ; mV ranges >1 MΩ; both <100 pF nominal |
Outside the 18–28 °C accuracy band, the temperature coefficient is 0.1 times the specified accuracy per °C. The display updates three times per second; Data Hold freezes the displayed value and must not be used to check unknown voltage.
Choosing the meter for your maintenance work
Panel and equipment checks
For trained electrical personnel, the 15B+ supports voltage checks on compatible circuits, DC control-supply diagnostics and continuity testing on isolated wiring. In commercial HVAC servicing, its capacitance and resistance functions help evaluate suitable disconnected components. For a capacitor or diode test, disconnect power and fully discharge hazardous capacitors first. The instrument is not a dedicated insulation resistance tester, clamp meter or power-quality analyser.
Safety category and current duty limits
Do not infer CAT III 1000 V capability from the 1000 V measurement range. The documented common rating is CAT III 600 V; the revised safety sheet specifies a 600 V terminal-to-earth maximum and a 1000 V V-COM maximum. Until the actual unit marking and matching safety sheet are confirmed, observe the more restrictive 600 V terminal-to-earth limit and do not assume any additional category rating. Use the lower rating of the meter, probes and accessories, with protective probe caps for CAT III work. At 10 A, the specified duty cycle is less than 7 minutes on, followed by 20 minutes off. Current measurement requires the appropriate fused input and a series connection established with circuit power removed; never connect the current input across a voltage source. Only trained personnel should perform hazardous electrical measurements with appropriate protective equipment.
IP40 does not provide water protection. Avoid damp, wet or explosive environments. The revised manufacturer safety information identifies Class A electromagnetic compatibility and states the equipment is not intended for residential environments; select equipment suited to the working environment.
Fluke 15B+ versus additional measurement functions
Choose the 15B+ when standard voltage, current, resistance and component checks are sufficient. Frequency, duty cycle, temperature, relative measurement and MIN/MAX recording are not 15B+ functions. The 17B+ provides those additional functions. Do not select the 15B+ as a True RMS meter for distorted AC waveforms; select an explicitly rated True RMS instrument where required. The 15B MAX is a different model, not another spelling of 15B+.
Compare other digital multimeters
Explore Fluke test instruments
Standard manufacturer package and procurement checks
Fluke specifies the 15B+ meter, TL75 test leads with two protective caps, two AA batteries and a user manual in the standard configuration. Optional accessories are not part of this standard list. Confirm the seller’s unit of sale, exact included items, safety marking and warranty terms before ordering. If your maintenance procedure requires traceable calibration, request the appropriate documentation for the actual instrument. Fluke recommends a 12-month calibration cycle; this does not mean an individual calibration certificate is included.
Browse test and measurement instruments
Frequently asked questions
1. Does Fluke 15B+ measure both AC and DC current?
Yes. It provides µA, mA and A ranges for AC and DC, up to 10 A subject to its specified duty cycle. The 400 mA input is not the 10 A input.
2. Is Fluke 15B+ a 1000 V CAT III multimeter?
No. The 1000 V voltage range does not establish a CAT III 1000 V rating. CAT III 600 V is the common documented rating; confirm the actual instrument marking and its safety sheet before selecting it for a circuit.
3. Can I measure frequency, duty cycle or temperature with the 15B+?
No. Choose an instrument specified for these measurements, such as the 17B+ for all three. The 40–500 Hz AC voltage specification is an input-frequency band, not a frequency measurement function.
4. What is supplied with the Fluke 15B+?
The standard manufacturer configuration comprises the meter, TL75 leads with two protective caps, two AA batteries and a user manual. Confirm the exact seller package and any optional leads, strap or certificate before ordering.
5. Can this meter measure motor or inverter current?
It can measure current only within the applicable range, circuit rating and duty cycle. Do not use it as a True RMS or variable-frequency drive diagnostic instrument. For high current or distorted waveforms, select a suitably rated clamp meter or True RMS instrument.
6. Is a calibration certificate or warranty included?
Ask Indus MegaMart to confirm the warranty applicable to the supplied unit and whether a calibration certificate is included or can be separately arranged. Calibration accuracy specifications do not constitute an individual calibration certificate.
7. Can I order more units than are available for delivery in Jaisalmer?
Yes. Indus MegaMart accepts orders and payment even when the quantity exceeds available stock or stock is zero. Its delivery policy is within 7 days for quantities within stock, and 7–14 days for excess or zero stock. Confirm the delivery estimate for your Jaisalmer pincode before payment.
Buy the Fluke 15B+ Digital Multimeter for delivery in Jaisalmer