Fluke 289 True RMS Industrial Logging Digital Multimeter in Jaipur
Order the Fluke 289 from Indus MegaMart for electrical maintenance, plant automation and industrial troubleshooting in Jaipur. This handheld True RMS digital multimeter combines AC/DC measurements up to 1000 V and 10 A with interval and event recording. Its TrendCapture display lets engineers examine changing readings directly on the instrument, making it useful when an intermittent fault is difficult to observe during a single site visit.
Check price and order the Fluke 289 in Jaipur
Review the current price, applicable GST, selling quantity and delivery availability for your Jaipur PIN code on the product listing before placing your order. For maintenance teams purchasing multiple instruments, confirm the number of meters required and any additional accessories or calibration documentation before checkout. Purchase invoices include the company’s GST number.
Buy Fluke 289 True RMS Industrial Logging Digital Multimeter
See intermittent electrical faults with TrendCapture
A conventional spot reading may look normal by the time a technician arrives. The Fluke 289 records measurements at selected intervals and can capture events defined by an adjustable change threshold. Review the resulting time-stamped graph on the meter, zoom into a suspect region and compare readings before and after a change. This supports investigation of fluctuating power supplies and control signals without relying on handwritten readings alone.
For longer sessions, balance the sample interval, duration, available memory and battery condition. Event logging is not a substitute for capturing a complete fast waveform; peak capture can detect brief changes as fast as 250 µs under the specified measurement conditions.
Technical specifications of the Fluke 289
|
Parameter |
Specification |
|
Model / display |
Fluke 289; 50,000-count backlit quarter-VGA display |
|
AC / DC voltage |
50 mV, 500 mV, 5 V, 50 V, 500 V, 1000 V ranges; AC True RMS |
|
DC voltage accuracy |
500 mV, 5 V and 50 V: ±(0.025% + 2 counts); 500 V and 1000 V: ±(0.03% + 2 counts), under specified conditions |
|
AC / DC current |
500 µA, 5000 µA, 50 mA, 400 mA, 5 A, 10 A ranges; AC True RMS |
|
Resistance |
50 Ω to 500 MΩ ranges; 50 Ω range: 0.001 Ω resolution; 10 mA source current |
|
Capacitance |
Ranges from 1 nF to 100 mF |
|
Frequency |
Ranges from 99.999 Hz to 999.99 kHz; input sensitivity and voltage-frequency limits apply |
|
Temperature |
−200 to +1350 °C (meter range, excludes probe limitations; compatible probe required) |
|
Other measurement functions |
Continuity, diode test, conductance (50 nS range), duty cycle, pulse width, dBV/dBm, relative mode, MIN/MAX/AVG, hold |
|
Logging and display |
Interval/event logging, TrendCapture, up to 14× trend zoom; up to 15,000 combined records, subject to memory |
|
Safety rating |
CAT III 1000 V / CAT IV 600 V; 1000 V maximum terminal to earth |
|
Operating / storage |
−20 to +55 °C operating; −40 to +60 °C storage; operating altitude up to 3000 m |
|
Relative humidity |
0–90% at 0–37 °C; 0–65% at 37–45 °C; 0–45% at 45–55 °C |
|
Power / dimensions |
6 AA alkaline cells; 222 × 102 × 60 mm (H × W × depth); manufacturer specifies 100 h minimum, 200 h in logging mode |
|
Interfaces |
Isolated optical interface; optional ir3000 FC connector for Fluke Connect; optional PC cable/software |
Accuracy is function-, range-, frequency- and condition-dependent. For example, on the 10 A DC range the manual specifies ±(0.3% + 2 counts); the 10 A AC range at 45 Hz–1 kHz is ±(0.8% + 5 counts). Do not apply the headline DC voltage accuracy to every function. The manual and its supplement provide the applicable limits.
Where the Fluke 289 fits industrial maintenance
Variable-frequency drives and noisy electrical signals
The low-pass filter helps evaluate AC voltage and frequency in motor-drive and inverter systems where higher-frequency components can affect readings. Never use the filter to establish absence of hazardous voltage; follow the manufacturer’s instructions and approved electrical safety procedures. The 289 also offers a smoothing mode when a stable display is useful.
Control panels and intermittent supply changes
For a control cabinet, investigate whether an unstable DC supply or an AC voltage change coincides with a machine interruption. LoZ voltage can help distinguish induced or phantom readings from a supported supply; it loads the circuit and is not suitable for every sensitive electronic signal. Use the appropriate input mode for the circuit.
Motor windings and contact resistance
The 50 Ω range with milliohm resolution assists comparisons between de-energised motor windings or contacts. Relative mode helps compensate for test-lead resistance. This two-terminal measurement is not equivalent to a dedicated four-wire micro-ohmmeter, particularly when very small resistance differences determine acceptance.
Safety, accessories and instrument selection
Use the meter only within its measurement category and voltage limits and with probes and accessories rated for the task; the lowest-rated component governs the combination. It is intended for trained personnel in industrial environments. For direct current measurement above 10 A, select a compatible, appropriately rated clamp instead of assuming the meter can continuously handle the higher load.
Fluke’s standard 289 product listing identifies the meter, TL71 test leads, AC175 alligator clips, six installed AA batteries and a quick reference guide. Confirm the supplied accessory configuration when ordering: Fluke documentation also identifies TL175 leads and other clips in its replacement-parts information. The temperature probe, ir3000 FC connector and PC software/cable are not assumed to be included. The standard 289 is distinct from the 289/FVF software kit.
If you only need basic spot measurements, compare the wider range of digital multimeters before selecting a logging model. For recurring faults, the 289’s onboard graphs, event recording and specialised industrial functions provide a clearer reason to choose it.
Explore digital multimeters
Explore Fluke instruments
Delivery and procurement for Jaipur
Indus MegaMart supplies test and measurement instruments to buyers in Jaipur and the surrounding NCR region. Enter the delivery PIN code and confirm the selling quantity and applicable offer. Under the ordering policy, quantities within available stock are delivered within 7 days; quantities above available stock, including zero-stock orders, are delivered within 7–14 days, subject to serviceability. Orders and payment remain accepted even when the available stock is insufficient. For warranty, return conditions or a calibration certificate, confirm the seller’s terms for the exact instrument before purchase.
Frequently asked questions
1. Can I use TrendCapture without a computer?
Yes. The 289 plots stored measurement trends on its own screen and allows up to 14× zoom. A PC is optional for exporting and documenting measurements.
2. How many readings can the Fluke 289 log?
The instrument supports up to 15,000 combined records. A recording session can contain up to 10,000 interval samples; available event records are limited by the remaining memory. Existing saved sessions reduce the capacity.
3. Does the Fluke 289 have Bluetooth built in?
No built-in wireless connection is claimed for the standard meter. Fluke lists the separately sold ir3000 FC infrared wireless connector for Fluke Connect communication. Confirm current app and device compatibility before buying the accessory.
4. Can the meter measure 20 A continuously?
No. The specified direct current range ends at 10 A. The manual permits 10–20 A only for 30 seconds followed by 10 minutes off, and accuracy above 10 A is not specified. Choose an appropriately rated current clamp for higher currents.
5. Is the 289 an insulation resistance tester?
No. Its 500 MΩ resistance range is a multimeter function, not a high-voltage insulation-resistance test. Choose a dedicated insulation tester if the procedure requires a specified insulation test voltage.
6. What is the difference between Fluke 287 and 289?
Both are logging DMMs. The 289 adds industrial functions including LoZ voltage, a low-pass filter and a dedicated 50 Ω resistance range. Choose it when those functions are needed for the work.
7. Can I place an order if the requested quantity exceeds stock?
Yes. Indus MegaMart accepts orders and payment even when the requested quantity exceeds available stock or stock is zero. For a serviceable delivery address, the applicable policy is 7–14 days in these cases.
Choose the Fluke 289 for industrial measurement and fault logging. Check the current offer and place your order for delivery to your Jaipur address.
Buy Fluke 289 True RMS Industrial Logging Digital Multimeter