Pilz 774738 PNOZ X4 Safety Relay 230 V AC 3 NO 1 NC in Jabalpur
For a control panel specified for a Pilz PNOZ X4 with a 230 V AC supply, 774738 is the 230 V AC version to check when ordering. It is a standalone safety relay for emergency-stop and safety-gate monitoring, with three normally-open safety contacts and one normally-closed auxiliary contact. The 45 mm-wide relay uses fixed screw terminals, making its exact part number important for replacement and panel procurement in Jabalpur.
Review the current price, GST basis, selling unit and required quantity on the exact product listing before ordering. Check your Jabalpur delivery pincode and make sure the part number matches your bill of materials or existing relay label.
Buy / view current price – Pilz PNOZ X4 774738
Technical specifications for 774738
|
Parameter |
Specification |
|
Manufacturer / model |
Pilz / PNOZ X4 |
|
MPN / GTIN |
774738 / 4046548010367 |
|
Supply |
230 V AC, 50–60 Hz; −15%/+10%; 5 VA |
|
Inputs and start |
Single- or dual-channel; short detection as wired; automatic, manual or monitored start |
|
Outputs |
3 instantaneous NO safety contacts; 1 NC auxiliary contact; no semiconductor output |
|
Control circuits |
24 V DC control circuits (input, start and feedback) |
|
Safety contact rating |
AC-1: 8 A at 240 V AC; DC-1: 8 A at 24 V DC; AC-15: 5 A at 230 V AC; DC-13: 7 A at 24 V DC (6 cycles/min) |
|
Mounting and connections |
DIN rail; fixed integral screw terminals |
|
Dimensions / weight |
87 × 45 × 121 mm (H × W × D); 370 g |
|
Protection / ambient |
Housing IP40; terminals IP20; cabinet IP54; −10 to +55°C, no condensation |
|
E-stop release time |
15 ms typical, 30 ms maximum (relay only) |
|
OEM-listed approvals |
CCC, CE, UKCA, cULus Listed, TÜV, EAC |
Where this PNOZ X4 fits
For an emergency-stop circuit or monitored guard, this relay provides safety-related circuit interruption through its three NO contacts. The NC auxiliary contact is for status or signalling, not an additional safety output. Input wiring can be single- or dual-channel, with short-circuit detection between channels where the approved circuit design supports it. Select a restart mode that prevents unexpected machine restart.
Pilz lists PL e, Category 4 and SIL 3 component safety characteristics, subject to the manual’s conditions. These do not establish the safety level of the complete machine. The full safety function, contact load, switching frequency, service life and feedback arrangement must be assessed and validated by qualified personnel. Refer to applicable Pilz operating manual before installation and commissioning.
Replacement checks before placing an order
Match the actual supply and contact arrangement, not just the PNOZ X4 name. 774739 is the 240 V AC variant, while 774730 is the 24V DC variant. Check the fixed terminal arrangement, cabinet space and applicable load category. Do not assume all three safety contacts can carry the single-contact maximum simultaneously; consult the manufacturer’s simultaneous-load and service-life limits.
If your panel requires a different output count or terminal style, compare other Pilz safety relays before selecting a substitute.
Browse safety relays
Explore Pilz products
Ordering and delivery in Jabalpur
Indus MegaMart accepts orders and online payment even when available stock is zero. When your required quantity is within available stock, delivery is within 7 days. If your order exceeds available stock, including zero-stock orders, delivery is within 7–14 days. Confirm serviceability for the destination pincode. For multiple units, check the listed selling unit, quantity, applicable GST and the total before payment. The generated invoice includes the company’s GST number.
Frequently asked questions
1. Is the NC contact a fourth safety output?
No. The three NO contacts are the safety outputs; the NC contact is auxiliary and must not be treated as a safety output.
2. Can I replace a 24 V or 240 V PNOZ X4 with 774738?
Do not substitute on the family name alone. 774738 is the 230 V AC version; 774730 is 24 V DC, and 774739 is the 240 V AC variant. Check the existing supply, wiring, and validated safety design.
3. Does the 230 V supply mean the inputs use 230 V?
No. The relay has 24 V DC control circuits for the input, start and feedback loop. Use the wiring instructions for the exact variant.
4. Is an 8 A contact rating valid for every load?
No. The rating depends on utilisation category, voltage, number of loaded contacts and switching frequency. For example, the AC-15 rating is 5 A at 230 V AC, not 8 A.
5. Can the PNOZ X4 monitor a safety gate?
Yes, it is intended for safety-gate and emergency-stop monitoring. Select an input and restart arrangement that meets the machine risk assessment; commissioning must be performed by qualified personnel.
6. Can I order more than available stock in Jabalpur?
Yes. Indus MegaMart accepts orders and payment even when stock is zero. For quantities exceeding available stock, including zero-stock orders, delivery is within 7–14 days under the ordering policy. Confirm serviceability for your delivery pincode.
7. Will the invoice include GST details?
The generated purchase invoice includes the company’s GST number. Check the displayed tax basis and selling unit for 774738 before payment.
Order the exact Pilz 774738 safety relay
Confirm the 230 V AC model, quantity and delivery details, then continue to the product listing to complete your purchase.
Buy Pilz 774738 PNOZ X4 safety relay