Buy Pilz PNOZ X9 Safety Relay 24VAC/DC 7NO 2NC 2SO (774609) in Haldwani
For a Haldwani maintenance order or a new control panel requiring multiple instantaneous safety contacts, the Pilz PNOZ X9, order number 774609, combines seven normally open safety contacts with two auxiliary contacts and two semiconductor outputs. It accepts 24 V AC or 24 V DC and monitors emergency-stop and safety-gate circuits in appropriately designed machinery. The fixed screw connections and 90 mm housing width are important details when matching an existing panel.
Check price and order Pilz 774609 for Haldwani
Use the exact product listing to review the current price, GST breakdown and quantity. Pilz lists one relay per manufacturer packaging unit; confirm the commercial selling unit and order quantity with Indus MegaMart, particularly for a multi-relay purchase. Use the delivery PIN code for your Haldwani site when confirming serviceability and shipping terms. Generated purchase invoices contain the company’s GST number.
Buy Now – Pilz PNOZ X9 774609
Technical specifications for PNOZ X9 774609
|
Specification |
Manufacturer data |
|
Brand / model |
Pilz / PNOZ X9 |
|
Order number / GTIN |
774609 / 4046548010657 |
|
Supply |
24 V AC (50–60 Hz) or 24 V DC; −15% / +10% |
|
Power requirement |
11 VA AC; 5.5 W DC |
|
Input arrangement |
Two inputs; single- or dual-channel options; cross-short detection depends on wiring |
|
Start modes |
Automatic, manual, monitored; automatic with start-up test |
|
Safety contacts |
7 NO, instantaneous, positively guided |
|
Auxiliary contacts |
2 NC, status only |
|
Semiconductor outputs |
2 signalling outputs, 24 V DC, 20 mA; external 24 V supply |
|
Contact rating |
AC1: 8 A at 240 V; DC1: 8 A at 24 V; AC15: 5 A at 230 V; DC13: 7 A at 24 V (6 cycles/min); derating applies |
|
E-STOP drop-out |
20 ms typical; 30 ms maximum; not total machine stopping time |
|
Dimensions (H × W × D) |
87 × 90 × 121 mm |
|
Mounting / connection |
35 mm DIN rail; fixed screw terminals |
|
Operating environment |
−10 to +55 °C; no condensation |
|
Protection |
Housing IP40; terminals IP20; cabinet minimum IP54 |
|
Net weight |
750 g |
|
Component safety data |
PL e, Category 4; SIL 3, subject to complete application design and validation |
|
OEM packaging |
1 relay per manufacturer packaging unit |
When the seven safety contacts matter
The relay can suit an engineered emergency-stop or guard-monitoring circuit where one safety function must control several downstream devices. For example, a panel designer may need several safety-related command paths and separate status indication. Seven instantaneous contacts can provide those paths within the limits of the approved circuit design. The two NC contacts and two semiconductor signals serve monitoring or indication, not safety circuits.
The relay supports automatic and monitored restart arrangements, as well as manual start and start-up testing options. Choose the start behaviour according to the risk assessment; avoid unintended machine restart. Suitable light grids or safety switches may also be considered only with the validated input arrangement in the Pilz manual. Feedback monitoring and external contactor selection must follow that design.
Contact loading and panel space
Do not treat the 8 A AC1/DC1 maximum as a rating for each of seven contacts simultaneously. The thermal current limits depend on the number of loaded contacts and whether the relay uses an AC or DC supply. The manufacturer specifies the following values for AC1 at 240 V and DC1 at 24 V.
| Loaded contacts |
AC supply: A/contact |
DC supply: A/contact |
|
1 |
8 |
8 |
|
2 |
5.6 |
8 |
|
3 |
4.6 |
8 |
|
4 |
4 |
7 |
|
5 |
3.5 |
6 |
|
6 |
3.2 |
5.5 |
|
7 |
3 |
5 |
Check the actual utilisation category, switching frequency, protection and service-life curves before selecting loads. Reserve space for the 90 mm width and the wiring inside an IP54 or better control cabinet. Pilz lists CE, CCC, UKCA, cULus Listed, EAC and TÜV approvals for this component. The component’s stated PL e / Category 4 and SIL 3 data do not establish the performance of the complete machine safety function. A competent safety engineer must design and validate that function, following the applicable Pilz instructions.
Match the supply variant before replacing a relay
The PNOZ X9 family contains similar-looking variants. Order number 774605 accepts 100–120 V AC or 24 V DC, while 774606 accepts 200–230 V AC or 24 V DC. The 774609 accepts 24 V AC or 24 V DC. Do not select a replacement by appearance or contact count alone. Compare the nameplate, supply, connections, dimensions and safety circuit. For other options, browse the following product ranges.
Explore Pilz products
Compare safety relays
Electrical and industrial automation
Stock, quantity and delivery to Haldwani
Indus MegaMart accepts orders and payment even if the requested quantity exceeds stock. The standard delivery policy for a serviceable destination is delivery within 7 days when the order quantity is within available stock, or within 7–14 days when the quantity exceeds available stock, including zero stock. Confirm your delivery PIN code and the quantity required for your maintenance or project purchase. Confirm product condition, warranty and return terms before payment; these are particularly important for safety-critical replacement parts.
Frequently asked questions
1. Can 774609 operate from a 24 V AC supply?
Yes. The 774609 variant accepts either 24 V AC or 24 V DC. The AC supply must be 50–60 Hz, and the DC supply must satisfy the manufacturer’s protective separation requirements.
2. Are the 2 NC and 2 SO outputs safety outputs?
No. Only the seven instantaneous NO relay contacts are safety contacts. The NC auxiliary contacts and semiconductor signalling outputs are not for safety circuits.
3. Can all seven contacts carry 8 A at the same time?
No. With seven contacts loaded, Pilz specifies conventional thermal current of 3 A per contact on AC supply or 5 A on DC supply, for AC1 at 240 V or DC1 at 24 V. The load category and service-life limits must also be satisfied.
4. Is 774609 interchangeable with other PNOZ X9 variants?
Not automatically. Check the order number, supply options, terminal arrangement, external circuitry and validated safety design. A similar model name or identical output count is not sufficient evidence of interchangeability.
5. What is the maximum emergency-stop response time of the relay?
The manufacturer specifies a maximum E-STOP de-energisation delay of 30 ms. This is a relay-level figure; actual stopping time includes the rest of the machine safety system.
6. Can I order more than the stock available?
Yes. Indus MegaMart accepts orders and payment even when the requested quantity exceeds available stock, including zero stock. For serviceable addresses, the stated delivery policy is 7–14 days in that case.
7. How do I check the selling pack, price and invoice?
Pilz lists one relay per manufacturer packaging unit. Confirm the commercial selling unit and current GST price breakdown with Indus MegaMart before buying. Generated purchase invoices contain the company’s GST number.
Order the exact Pilz PNOZ X9 774609
Match the relay to your approved bill of materials, confirm the selling unit and Haldwani delivery details, and continue to the exact product listing to complete your purchase.
Buy Now – Pilz 774609 PNOZ X9 Safety Relay