Order the Fluke 117 from Indus MegaMart for electrical maintenance and installation work in Guntur. This compact True RMS digital multimeter is designed for electricians who need to distinguish induced voltages from genuine circuit readings, screen for AC voltage presence and measure electrical parameters with a single instrument. Its CAT III 600 V rating, 10 A AC/DC current-measurement capacity and integrated VoltAlert make it a practical choice for trained facility technicians, contractors and maintenance teams.
Check the current GST-inclusive price and available quantity, select the required model and confirm delivery to your Guntur pincode. For multiple meters or a procurement order, confirm the selling unit and included accessories before payment.
Buy Fluke 117 / Check price and delivery
Why choose the Fluke 117 for electrical troubleshooting?
VoltAlert and Auto-V LoZ
VoltAlert provides visual and audible indications of nearby AC voltage, with two sensitivity settings. It helps identify where further testing is needed. No indication does not establish that a conductor is safe to touch; shielding, insulation, and connector geometry can affect detection. Always follow approved isolation and contact-testing procedures.
Auto-V LoZ automatically selects AC or DC voltage and uses approximately 3 kΩ input impedance to reduce misleading readings caused by capacitive coupling. Use the ordinary high-impedance voltage modes for sensitive control and electronic circuits where LoZ could load the circuit. True RMS AC measurement helps characterise distorted waveforms within the instrument’s specified frequency and crest-factor limits.
Readable measurements in the field
The backlit 6,000-count display and 33-segment bar graph help when working in dim equipment rooms. Hold retains a displayed value; Min/Max/Average helps capture changes during a measurement session. The meter supports automatic and manual range selection. The ordinary AC voltage input impedance is above 5 MΩ and DC voltage above 10 MΩ.
Fluke 117 measurement specifications
Accuracy below is expressed as ±(percentage of reading + display counts), specified for one year after calibration at 18–28°C and 0–90% RH. AC ranges generally specify accuracy from 1% to 100% of range, except Auto-V LoZ. The voltage crest factor is up to 3 at 4,000 counts, falling to 1.5 at full scale; the current crest factor is up to 3.
| Function |
Range |
Resolution |
Accuracy/conditions |
|
DC voltage |
6.000 / 60.00 / 600.0 V |
0.001 / 0.01 / 0.1 V |
0.5% + 2 |
|
DC mV |
600.0 mV |
0.1 mV |
0.5% + 2 |
|
AC voltage, True RMS |
6.000 / 60.00 / 600.0 V |
0.001 / 0.01 / 0.1 V |
1% + 3 at 45–500 Hz; 2% + 3 at 500 Hz–1 kHz |
|
AC mV, True RMS |
600.0 mV |
0.1 mV |
Same as AC volts |
|
Auto-V LoZ |
600.0 V |
0.1 V |
2% + 3 DC / 45–500 Hz; 4% + 3 at 500 Hz–1 kHz |
|
AC current, True RMS |
6.000 / 10.00 A |
0.001 / 0.01 A |
1.5% + 3 at 45–500 Hz |
|
DC current |
6.000 / 10.00 A |
0.001 / 0.01 A |
1% + 3 |
|
Resistance |
600.0 Ω; 6.000 / 60.00 / 600.0 kΩ; 6.000 / 40.00 MΩ |
0.1 Ω; 0.001 / 0.01 / 0.1 kΩ; 0.001 / 0.01 MΩ |
0.9% + 2 at 600 Ω; 0.9% + 1 through 6 MΩ; 5% + 2 at 40 MΩ |
|
Continuity |
600 Ω |
1 Ω |
Beeper on below 20 Ω; off above 250 Ω; detects events ≥500 µs |
|
Diode |
2.000 V |
0.001 V |
0.9% + 2 |
|
Capacitance |
1000 nF; 10.00 / 100.0 / 9999 µF |
1 nF; 0.01 / 0.1 / 1 µF |
1.9% + 2 through 1000 µF; 5% + 20 above 1000 µF |
|
LoZ capacitance |
1 nF–500 µF |
Mode dependent |
10% + 2 typical |
|
Frequency |
99.99 Hz; 999.9 Hz; 9.999 / 50.00 kHz |
0.01 Hz; 0.1 Hz; 0.001 / 0.01 kHz |
0.1% + 2; input conditions apply |
Frequency measurement is specified over 5 Hz–50 kHz on the AC voltage input and 45 Hz–5 kHz on the AC current input in the extended specification. For applications above 50 kHz, confirm the applicable frequency limit in the manual supplied with your meter. Frequency counting needs a sufficient signal amplitude and is not the same as True RMS voltage accuracy bandwidth.
Safety, construction and operating conditions
|
Parameter |
Specification |
|
Measurement category |
CAT III 600 V, 10 A; IEC 61010-1 pollution degree 2 / IEC 61010-2-033 |
|
Terminal-to-earth limit |
600 V maximum |
|
Current input protection |
11 A, 1000 V fast fuse, interrupt rating 17 kA; Fluke PN 803293 |
|
Display / bar graph |
6,000 counts, 4 updates/s; 33 segments, 32 updates/s |
|
Operating / storage temperature |
−10 to +50°C / −40 to +60°C |
|
Altitude |
2,000 m maximum operating altitude |
|
Ingress protection |
IP42, non-operating; not intended for wet operation |
|
Battery |
9 V alkaline (IEC 6LR61); typically 400 hours without backlight |
|
Size and weight |
167 × 84 × 46 mm; 550 g (manufacturer catalogue) |
Direct current measurements are limited to 10 A under specified accuracy conditions. The manual allows a short overload above 10 A up to 20 A for no more than 30 seconds, followed by 10 minutes off; accuracy above 10 A is unspecified. This is not a 20 A continuous-current rating. For larger loads use a correctly rated clamp meter or compatible current probe. De-energize circuits and discharge capacitors before resistance, continuity, diode or capacitance testing. Follow the manufacturer’s safety instructions, correct terminals, suitable leads and site PPE requirements.
Where the Fluke 117 fits in your tool kit
Commercial building maintenance: check supply and control voltages, investigate apparent voltage on isolated wiring and verify continuity on de-energized circuits. Panel servicing: compare AC or DC readings against equipment requirements and use Min/Max/Average for intermittent variation. Workshop diagnostics: evaluate resistors, diodes and isolated capacitors within the stated measurement ranges. The instrument is EMC Class A; the safety sheet cautions that it is not intended for residential environments because of possible radio interference.
For electrical teams choosing between models, the Fluke 115 suits ordinary field measurements, while the 117 adds contactless AC screening and Auto-V LoZ. The Fluke 116 is aimed at HVAC work including native temperature and microamp measurement. The 117 is not an insulation-resistance tester, a power-quality analyzer, or a substitute for a dedicated high-current clamp meter.
Compare digital multimeters
Explore Fluke test instruments
Ordering the Fluke 117 in Guntur
For a maintenance department, contractor or facility store, confirm the exact 117 model, meter count, accessories, current price and warranty coverage before placing an order. Fluke’s standard package comprises the meter, one pair of 4 mm silicone test leads, holster and user documentation. Optional magnetic hanger, cases and probes are separate accessories unless expressly included in your order. Fluke describes a three-year limited manufacturer warranty; confirm the eligibility and service terms for the supplied unit.
Indus MegaMart accepts orders and payment even when requested quantity is higher than available stock, including zero stock. Under its stated policy, delivery is within 7 days when ordered quantity is within available stock, or within 7–14 days when it exceeds stock or stock is zero. Check delivery serviceability and the order-specific estimate using your Guntur pincode. The purchase invoice includes Indus MegaMart’s GST number.
Explore test and measurement instruments
Frequently asked questions
1. Does the Fluke 117 detect voltage without touching a wire?
VoltAlert senses AC voltage and provides audible and visual indications. It is a preliminary detection function, not proof that a circuit is dead. Shielding, insulation and socket geometry can affect detection. Use an appropriate contact test and approved isolation procedure.
2. Can the Fluke 117 measure 1,000 V or be used in CAT IV installations?
No. The Fluke 117 is rated CAT III 600 V, with a 600 V maximum terminal-to-earth rating. The 1,000 V marking in the fuse specification is not the meter’s voltage range. Select a suitably rated instrument and leads for higher category or voltage requirements.
3. Does the Fluke 117 have a milliamp range?
It has a 6.000 A range with 0.001 A resolution, so the display can resolve 1 mA. It does not have a dedicated mA or µA input. The 10.00 A range resolves 0.01 A; small AC currents have additional range constraints.
4. How does the Fluke 117 differ from the Fluke 115?
Both measure AC/DC voltage and current and offer True RMS, resistance, capacitance and frequency. The 117 adds VoltAlert and automatic AC/DC selection with low input impedance, making it particularly useful for building electrical diagnostics.
5. Can the Fluke 117 measure temperature?
The 117 has no built-in thermocouple temperature measurement mode. Its operating-temperature specification describes the environment in which the meter is used, not a temperature-measurement function. For native HVAC temperature and microamp measurements, evaluate the Fluke 116.
6. What comes with the Fluke 117?
The standard manufacturer package includes the meter, one pair of 4 mm silicone test leads, a holster and user documentation. Confirm the exact supplied configuration, selling unit and any optional accessories before ordering.
7. Is a GST invoice available for a Guntur order?
Indus MegaMart purchase invoices include the company GST number. Review the current GST-inclusive price, quantity and delivery details on the Fluke 117 product page before completing your purchase.
8. Can I order more Fluke 117 meters than the displayed stock?
Yes. Indus MegaMart accepts orders and payment even when the requested quantity exceeds available stock or stock is zero. The stated policy is delivery within 7 days for quantities within available stock, and within 7–14 days for excess or zero-stock orders. Confirm serviceability for your delivery pincode.
Ready to order? Buy the Fluke 117 Electrician’s Digital Multimeter