Pilz 777548 PNOZ XV2.1P Safety Relay in Ghaziabad - 24-240 V AC/DC
For a Ghaziabad maintenance team replacing a long-delay safety relay, the order number matters as much as the voltage. Pilz 777548 is the PNOZ XV2.1P standalone safety relay with a 24–240 V AC/DC supply, two instantaneous and two delayed normally open safety contacts, and twelve selectable release-delay positions from 0.3 to 300 seconds. It is intended for emergency-stop and safety-gate monitoring in validated industrial safety circuits. Pilz has discontinued this variant; confirm remaining stock and the condition of the exact unit before ordering from Indus MegaMart.
Check price and order the exact relay
Review the current GST-inclusive price on the product listing and confirm how many relays are included in the selling unit. Enter the Ghaziabad delivery pincode for your plant, workshop or project site. For replacement or project quantities, verify stock, condition, terminal blocks and delivery commitment before payment. Purchase invoices contain the company GST number.
Buy Now – Pilz 777548 PNOZ XV2.1P
Technical specifications
|
Parameter |
Specification |
|
Brand/model/part number |
Pilz / PNOZ XV2.1P / 777548 |
|
GTIN |
4046548009392 |
|
Supply voltage |
24–240 V AC/DC; AC 50–60 Hz; −15%/+10% tolerance |
|
Consumption |
8.5 VA AC; 5 W DC |
|
Monitoring/inputs |
2 inputs; single- or dual-channel wiring; cross-short detection according to wiring |
|
Start/feedback |
Automatic or monitored start; feedback loop; input, start and feedback circuits 24 V DC |
|
Safety outputs |
2 instantaneous NO + 2 off-delay NO; no semiconductor outputs |
|
Delay settings (seconds) |
0.3, 5, 10, 20, 40, 60, 80, 100, 150, 200, 250, 300 |
|
Timing accuracy |
−15% / +15% + 50 ms; repeatability 2% |
|
Contact ratings, both groups |
AC-1: 8 A at 240 V; DC-1: 8 A at 24 V; AC-15: 5 A at 230 V; DC-13: 7 A at 24 V (6 cycles/min). |
|
Simultaneous thermal load |
1/2/3/4 loaded contacts: 8/7/5.7/5 A per contact (AC-1/DC-1); observe all manual limits. |
|
Terminals and mounting |
Plug-in screw terminals; DIN rail; 0.25–2.5 mm² single flexible conductor |
|
Size (H × W × D) |
94 × 90 × 121 mm |
|
Net mass |
520 g |
|
Operating environment |
−10 to +55 °C; no condensation; IP40 housing, IP20 terminals; IP54 mounting area |
|
Manufacturer lifecycle |
Discontinued; verify remaining seller stock and condition |
Selecting the release delay and safety contacts
When a monitored safety input opens, one pair of safety outputs opens without intentional timing while the other pair opens after the selected interval. The delayed pair is intended for a designed stop sequence, not for postponing protective action just to complete production. Reset of the timing cycle can terminate the delay early, and the selected interval is not a substitute for standstill monitoring. A safety engineer must account for tolerance, power-loss behaviour, stopping time and restart prevention.
Safety characteristics of the two output groups
|
Output group |
OEM component characteristics |
|
Instantaneous contacts |
PL e / Cat. 4 / SIL 3 |
|
Delayed contacts, setting below 30 s |
PL d / Cat. 3 / SIL 3 |
|
Delayed contacts, setting 30 s or above |
PL c / Cat. 1 / SIL 1 |
These values apply under the conditions in the manufacturer’s manual, not automatically to the entire machine. The long-delay settings (40–300 s on this model) have a lower safety classification. Verify the required performance level, service-life limits, load and protective measures before selecting the delay. Do not allow access to a hazard solely on the basis of the timer.
Application and replacement decisions
The relay is intended for emergency-stop pushbuttons and safety gates. In a validated controlled-stop design, immediate contacts may initiate the stopping command while delayed contacts perform a subsequent safety-related interruption. This is a circuit-design example, not a recommendation to delay guard protection. The device does not command motor deceleration or confirm that movement has ceased. Compare the approved circuit drawings with the exact supply, terminal arrangement, required timing and load before replacing a unit. Automatic start requires safeguards against unintended restart.
Distinguish the related variants
|
Part number |
Selection difference |
|
777548 |
24–240 V AC/DC; 0.3–300 s; screw terminals |
|
777540 |
24–240 V AC/DC; up to 30 s; screw terminals |
|
777542 |
24–240 V AC/DC; up to 3 s; screw terminals |
|
787548 |
300-second family variant; spring-loaded terminals |
Pilz identifies PNOZsigma part numbers 750105, 751105, 750135 and 751135 as functionally compatible successors, subject to the application’s parameters. They are not automatic drop-in substitutes. Check the supply, delay range, output configuration, terminal technology, safety characteristics and wiring against the intended replacement. Optional spare screw-terminal sets 374281 (P3 + P4) and 374282 (two P5 blocks) are listed by Pilz; confirm package contents and separate accessory availability.
Delivery and procurement for Ghaziabad
Indus MegaMart’s standard ordering policy allows payment even at zero available stock. For serviceable destinations, the standard delivery policy is within 7 days when the requested quantity is within available stock, and 7–14 days when it exceeds available stock or stock is zero. As this exact model is discontinued, confirm the actual sourcing and delivery commitment for the required quantity before payment. For larger orders, confirm part condition, warranty and returns, pack quantity, and any documentation needed for approval.
Browse Pilz products
Compare safety relays
Electrical and industrial automation products
Frequently asked questions
1. Is 777548 the 300-second version?
Yes. It offers twelve discrete release-delay selections from 0.3 to 300 seconds. There is no 30-second setting on this exact version; 777540 is the separate up-to-30-second screw-terminal variant.
2. Can both delayed contacts be treated as PL e outputs?
No. Pilz specifies PL d / Category 3 / SIL 3 below 30 seconds and PL c / Category 1 / SIL 1 at 30 seconds or longer. The instantaneous contacts have different characteristics. Validate the complete safety circuit.
3. Does 777548 provide a guaranteed five-minute delay or detect standstill?
No. The 300-second position is a nominal release-delay setting, subject to tolerance and circuit behaviour. The relay does not measure motion or standstill; an appropriate safety design must establish when access is safe.
4. Is 777548 still manufactured?
Pilz lists this part as discontinued. Remaining merchant stock may be available; confirm the exact part, condition, history, included terminals and sourcing before committing. For migration, ask a qualified engineer to assess the OEM-listed successors.
5. Can I order more than the listed stock?
Indus MegaMart’s standard policy permits orders and payments even when available stock is insufficient or zero. Because 777548 is discontinued, confirm sourcing and the delivery commitment for your required quantity before paying.
6. How can I check the price and delivery for Ghaziabad?
Use the exact 777548 listing to view the GST-inclusive price, confirm the selling-unit quantity and enter your delivery pincode. For plant maintenance or a bulk requirement, confirm the lead time and applicable warranty/return terms with the seller.