Fluke 83 V Industrial Digital Multimeter Supplier in Ghaziabad
For electrical maintenance teams purchasing instruments in Ghaziabad, the Fluke 83 V is a handheld, average-responding industrial digital multimeter for sinusoidal AC and DC electrical measurements. It combines 1000 V AC/DC voltage ranges, 10 A direct-input AC/DC current ranges, a 6000-count display and resistance, conductance, capacitance, frequency, duty cycle, continuity and diode functions. Its CAT III 1000 V and CAT IV 600 V ratings make it relevant to qualified electrical professionals working within the appropriate installation categories. The 83 V is a specific 80 Series V model, not the True RMS 87 V. Order through Indus MegaMart for your Ghaziabad delivery address.
Price, ordering and delivery in Ghaziabad
Check the current Fluke 83 V price, GST treatment, selling unit, package details and available quantity on the product listing before placing your order. For procurement of multiple instruments, select the required quantity and confirm the delivery address and any calibration-document requirements. Purchase invoices include the company’s GST number.
Check price and buy Fluke 83 V online
Indus MegaMart accepts orders and payments even when available stock is insufficient or zero. For serviceable Ghaziabad addresses, delivery is within 7 days when the order quantity is within available stock; when the quantity exceeds available stock, including zero stock, delivery is within 7–14 days. Confirm serviceability for your delivery PIN code before purchase.
Fluke 83 V measurement specifications
|
Measurement/specification |
Fluke 83 V value or condition |
|
AC measurement method |
Average responding; calibrated for RMS of a sine wave |
|
DC voltage |
600.0 mV; 6.000 / 60.00 / 600.0 / 1000 V. Best mV resolution 0.1 mV; DC V accuracy ±(0.1% + 1 count), DC mV ±(0.3% + 1 count). |
|
AC voltage |
600.0 mV to 1000 V across five ranges; 0.1 mV best resolution. At 50–60 Hz: ±(0.5% + 2 counts) on V ranges; ±(0.5% + 4 counts) on 600 mV range. Add 10 counts below 200 counts. |
|
AC/DC current |
600.0 µA, 6000 µA, 60.00 mA, 400.0 mA, 6.000 A and 10.00 A; best resolution 0.1 µA. AC ±(1.2% + 2 counts), 45 Hz–2 kHz, add 10 counts below 200 counts. DC ±(0.4% + 2 or 4 counts), range-dependent. |
|
Resistance |
600.0 Ω to 50.00 MΩ; best resolution 0.1 Ω. Accuracy varies by range; e.g., ±(0.4% + 1 count) on 6 kΩ and 60 kΩ. |
|
Capacitance |
10.00 nF to 9,999 µF across specified ranges; best resolution 0.01 nF; ±(1% + 2 counts), with film capacitor or better and REL zeroing on the two lowest ranges. |
|
Frequency counter |
0.5 Hz–200 kHz, pulse width >2 µs; best resolution 0.01 Hz; ±(0.005% + 1 count), subject to trigger sensitivity and input limits. |
|
Duty cycle |
0–99.9%; 0.1% resolution; accuracy within ±(0.2% per kHz + 0.1%) for rise time <1 µs. |
|
Conductance |
60.00 nS; 0.01 nS resolution; ±(1% + 10 counts) using REL; add 20 counts below 33 nS. |
|
Continuity / diode |
Audible continuity; diode test 3.000 V range, 1 mV resolution, ±(2% + 1 count). |
|
Display |
6000-count LCD, four updates/s; analog bar graph at 40 updates/s; two-level backlight. Frequency display has 19,999 counts. |
|
Safety |
CAT III 1000 V / CAT IV 600 V; IEC 61010-1 and IEC 61010-2-033; Pollution degree 2. Fuses: 0.44 A/1000 V (µA/mA), 11 A/1000 V (A input). |
|
Environment |
Operating −20°C to +55°C; storage −40°C to +60°C; operating altitude up to 2,000 m. |
|
Dimensions / mass |
H × W × L: 31 × 86 × 186 mm, 355 g bare meter; 52 × 98 × 201 mm, 624 g with holster and flex-stand. |
|
Battery |
One 9 V battery; about 400 hours typically with alkaline battery and backlight off. |
Accuracy expressions are percentage of reading plus display counts. The manual bases detailed accuracy on 18°C–28°C, up to 90% relative humidity and one year after calibration. Resolution is not the same as accuracy. AC specifications depend on the selected range and signal frequency.
Current-input and frequency limits
The 10 A input is not an unrestricted 20 A input. Fluke specifies 10 A continuous up to 35°C and, at 35°C–55°C, 20 minutes on followed by 5 minutes off. Above 10 A and up to 20 A, the limit is 30 seconds on followed by 5 minutes off; accuracy above 10 A is unspecified. The mA input is rated for 400 mA continuous, with 600 mA permitted for up to 18 hours under the manual’s conditions. Use a suitable rated current clamp or clamp meter where the direct-input limits are insufficient.
The 200 kHz counter is not a 200 kHz AC voltage accuracy specification. On the 83 V, AC voltage accuracy is specified from 30 Hz to 1 kHz across the voltage ranges, with 1–5 kHz specifications on lower ranges, a 2.5 kHz limit on the 600 V range and no specified high-band accuracy on the 1000 V range. Frequency counter sensitivity depends on range and signal amplitude. Respect the safety sheet’s frequency overload limit of 1,000,000 V·Hz and the lowest-rated component of the meter, leads and accessories. Only trained personnel should use the instrument on electrical installations. Isolate circuits and discharge capacitors before resistance, continuity or capacitance testing. Do not use AutoHOLD to establish absence of voltage.
Where the 83 V is useful in maintenance work
Power and control panels
Use the voltage and frequency functions for suitable sinusoidal supply checks and the DC functions for control supply and electronics diagnostics. The analog bar graph helps show changing readings while MIN/MAX/AVG captures variations during a measurement session.
Maintenance of isolated components
Resistance, continuity and diode measurements help assess connections, coils and semiconductor junctions in isolated circuits. Use REL to compensate for residual test-lead resistance where applicable. Capacitance testing helps evaluate discharged motor and other capacitors within the instrument’s range.
Workshop and field practicality
Auto or manual ranging, AutoHOLD, two-level backlighting and selectable sleep mode support routine measurements. The battery access door and removable holster with probe storage simplify normal handling. Its industrial Class A electromagnetic environment rating does not make it intrinsically safe or suitable for every location.
Choose the 83 V or a True RMS meter?
The Fluke 83 V measures AC by an average-response method scaled for sine waves. This is appropriate for suitable linear-load and sinusoidal measurements, but distorted waveforms from switching supplies, nonlinear loads or PWM drive outputs may produce misleading AC readings. Choose an appropriately rated True RMS model if the measurement requires accurate RMS values on non-sinusoidal waveforms. In the 80 Series V family, the Fluke 87 V adds True RMS AC response, a selectable low-pass filter, a temperature input and a higher-resolution mode. The 83 V does not include those functions. Even with a True RMS meter, verify waveform, crest factor, frequency and probe ratings for the specific application.
Compare other Fluke instruments
Explore digital multimeters
Standard manufacturer box contents
Fluke lists one 83 V meter, one pair of TL75 test leads, one pair of AC175 alligator clips, a holster, an installed 9 V battery and a quick reference guide in its standard product package. Optional current clamp accessories and a compatible magnetic hanger are separate items. Confirm the supplied regional package and seller’s unit of sale with the actual listing before ordering; the manufacturer’s standard package does not establish the seller’s commercial pack or any calibration certificate.
Browse test and measurement instruments
Frequently asked questions
1. Is the Fluke 83 V a True RMS digital multimeter?
No. The 83 V is average responding and its AC response is calibrated for sine-wave measurements. If distorted AC waveforms must be measured, choose a suitable True RMS instrument that meets the safety and bandwidth requirements.
2. Can the Fluke 83 V measure 1000 V in a CAT IV environment?
No. Its 1000 V rating applies to CAT III; CAT IV is limited to 600 V. All leads and accessories must also be appropriate to the measurement category and voltage.
3. Does the 200 kHz frequency range mean it measures AC voltage accurately at 200 kHz?
No. The frequency counter and AC voltage accuracy specifications are different. Check the manual’s AC voltage range and frequency band, counter sensitivity and safety limits for the intended signal.
4. Does the Fluke 83 V measure temperature directly?
No. The 83 V has no dedicated temperature measurement function. The Fluke 87 V includes that function; a temperature probe is not part of the 83 V standard manufacturer package.
5. What warranty applies to the Fluke 83 V?
Fluke describes the 83 V under its limited lifetime warranty for eligible original purchasers. The manufacturer’s terms exclude items such as disposable batteries and fuses, misuse and normal mechanical wear. Confirm purchase eligibility and warranty handling for the offered instrument before placing your order.
6. Can Ghaziabad buyers order the Fluke 83 V when the listed stock is zero?
Yes. Indus MegaMart accepts orders and payments even at zero stock; for serviceable addresses the delivery policy is 7–14 days when the ordered quantity exceeds stock. Check your required quantity and delivery details on the exact product listing.
Order the Fluke 83 V for Ghaziabad
Confirm the exact 83 V model, the commercial package, current product price and delivery details, then select the quantity you require.
Buy Fluke 83 V Industrial Digital Multimeter