Fluke 116 HVAC Digital Multimeter Supplier in Gaya
Order the Fluke 116 HVAC Digital Multimeter from Indus MegaMart for delivery to your Gaya service location. Built for heating, ventilation, air conditioning and refrigeration diagnostics, the 116 combines True-RMS AC voltage measurements with Type-K temperature sensing, AC/DC microamp measurements for flame sensors and a low-impedance voltage mode. It is particularly useful for technicians who need to investigate electrical control faults and temperature-related symptoms with one handheld instrument.
View the current GST-inclusive price, select your required quantity and check your delivery pincode on the product listing. Confirm the kit configuration before placing a team or project order.
Buy Fluke 116 HVAC Digital Multimeter
Technical specifications of the Fluke 116
|
Parameter |
Specification |
|
AC/DC voltage |
600 V maximum; AC True-RMS |
|
DC voltage accuracy |
±(0.5% of reading + 2 counts) |
|
AC voltage accuracy |
±(1% + 3 counts), 45–500 Hz; ±(2% + 3 counts), 500 Hz–1 kHz |
|
AC/DC millivolts |
600 mV; 0.1 mV resolution |
|
Microcurrent |
600 µA AC/DC; 0.1 µA resolution |
|
DC / AC microcurrent accuracy |
±(1% + 2 counts) DC; ±(1.5% + 3 counts) AC, 45–500 Hz |
|
Resistance |
600 Ω to 40 MΩ ranges |
|
Continuity |
Audible indication; on below 20 Ω, off above 250 Ω |
|
Capacitance |
Up to 9,999 µF; LoZ capacitance 1 nF–500 µF |
|
Frequency |
Up to 50 kHz for voltage input; subject to input conditions |
|
Diode test |
2 V range |
|
Temperature |
−40°C to +400°C; 0.1°C resolution; Type-K probe |
|
Display |
6,000 counts; 33-segment bar graph |
|
Safety |
CAT III 600 V; IEC 61010-1 / IEC 61010-2-033 |
|
Operating / storage temperature |
−10°C to +50°C / −40°C to +60°C |
|
Power |
9 V alkaline; typical 400 hours without backlight |
|
Size / mass |
167 × 84 × 46 mm / 550 g |
|
Manufacturer warranty |
3 years; applicable terms must be confirmed |
Accuracy depends on the selected range and operating conditions. Temperature accuracy excludes thermocouple error; the usable temperature range also depends on the probe. Follow the Fluke manual for the applicable input limits.
Where the Fluke 116 helps HVAC service teams
Control circuits and intermittent faults
True-RMS AC voltage measurement supports checks on compatible control supplies and electrical circuits. Min/Max/Average capture helps assess changing signals, while the backlit display improves readability in equipment rooms. LoZ helps investigate misleading readings caused by induced voltage; use the appropriate mode for the circuit.
Temperature and flame-signal diagnosis
The Type-K input lets technicians compare temperatures at appropriate measurement points during HVAC service. The microamp function supports flame-sensing circuits in compatible heating equipment. Neither function alone identifies the cause of a fault; compare results with the system manufacturer’s service criteria.
Capacitors and wiring checks
Capacitance, resistance, continuity and diode functions support component and wiring evaluation on safely isolated equipment. Capacitors must be safely discharged before testing. The meter is suited to trained maintenance teams working on air-handling units, commercial refrigeration controls and building services within its ratings.
Choosing the right meter and kit
Choose the 116 when temperature and microamp testing matter more than direct ampere measurement. It is not a direct 10 A multimeter, insulation tester or refrigerant pressure gauge. For motor load current, use an appropriately rated clamp meter. CAT III 600 V is a measurement-category limit, not permission to test every 600 V installation; observe the ratings of the meter, leads and accessories.
The standard Fluke kit lists the meter, a pair of 4 mm silicone leads, an 80BK integrated temperature probe, a holster, installed 9 V battery and quick reference guide. The optional ToolPak hanger is not part of that standard list. Confirm the seller’s actual bundle and applicable warranty terms before purchase.
Ordering for Gaya HVAC maintenance and procurement
For service teams working across Gaya, enter the destination pincode on the product listing and choose the quantity needed for technicians or maintenance contracts. Orders within available stock follow a delivery window of within 7 days. Orders exceeding stock, including zero-stock orders, remain eligible for payment and ordering under the 7–14 day delivery policy. Check the destination serviceability before committing to a maintenance schedule. Purchase invoices include the company GST number.
Compare other instruments if your work requires direct load-current measurement or different test functions.
Explore digital multimeters
Explore Fluke instruments
Browse test and measurement instruments
Frequently asked questions
1. Does the Fluke 116 measure compressor current in amperes?
No. Its direct current measurement is limited to microamps. Choose a suitably rated clamp meter for compressor or motor load current.
2. Can the Fluke 116 check flame sensors?
Yes. Its DC microamp function is intended for flame-signal diagnosis. Compare the reading with the equipment manufacturer’s specified range.
3. Is the temperature probe included?
Fluke lists the 80BK Type-K probe in the standard manufacturer kit. Confirm the offered seller configuration when ordering.
4. Does LoZ replace safe isolation procedures?
No. LoZ helps distinguish induced voltage from a driven supply; it does not prove a circuit is safe to touch. Follow the equipment and meter safety procedures.
5. Can I order more meters than the displayed stock?
Yes. Orders and payment are accepted even when requested quantity exceeds stock; the delivery policy for those orders is 7–14 days.
6. Is a GST invoice provided?
Yes. The purchase invoice includes Indus MegaMart’s GST number.
Buy the Fluke 116 in Gaya
Review the current price and offered kit, confirm your delivery pincode and place your order through the Fluke 116 product listing.
Buy Now – Fluke 116 HVAC Digital Multimeter