Pilz S1WP 9A True-Power Monitoring Relay 890020 - Dhanbad
Buy the Pilz S1WP 9A monitoring relay, manufacturer part 890020, through Indus MegaMart for a machine or control-panel requirement in Dhanbad. This 24 V DC unit measures true power for suitable single- and three-phase motor applications, including frequency-controlled motors. Its 9 A measuring-current variant supports a 0–415 V AC/DC measuring-voltage range and provides both an adjustable threshold relay and a selectable analogue output. Confirm the exact part number, current GST-inclusive price, order quantity and delivery pincode before checkout.
Check the exact model, live price and order quantity
- Manufacturer part: Pilz 890020
- Series: S1WP / PMDsrange
- Supply: 24 V DC
- Measuring input: 9 A
- Measuring-voltage variant: 0–415 V AC/DC
- Output: 1 changeover contact and 1 analogue signal.
The current price including GST, quantity availability and purchasing options are shown on the exact Indus MegaMart product listing. Enter your Dhanbad delivery pincode to check serviceability. Verify the seller’s selling unit and the total quantity required for your purchase order before payment.
Buy Pilz S1WP 9A 890020 – Exact Product.
What this S1WP relay actually measures
The S1WP is a true-power monitor rather than a conventional emergency-stop safety relay. It measures an electrical machine’s real power and compares the result with selected upper or lower thresholds. A changeover relay changes state when the configured underload or overload condition is reached, while the analogue output makes the measured value available to a compatible monitoring or control system.
True-power monitoring can help reveal a change in machine load that is not obvious from a simple on/off input. In an appropriately engineered installation, for example, an unexpected drop in driven-load power can indicate a process interruption, while excessive power may suggest a jam or load increase. Those are possible diagnostic uses, not a guarantee that the relay independently prevents every mechanical fault.
Pilz 890020 verified specifications
|
Attribute |
Verified information |
|
Manufacturer / product |
Pilz S1WP; PMDsrange true-power monitoring relay |
|
Manufacturer part number / GTIN |
890020 / 4046548007084 |
|
Supply voltage / consumption |
24 V DC / 2 W |
|
Measuring-current version |
9 A (measuring circuit; not relay switching-contact rating) |
|
Measuring-voltage version |
0–415 V AC/DC |
|
Measuring-frequency range |
0–1000 Hz |
|
Measuring ranges |
9 selectable ranges |
|
Threshold adjustment |
5–100% of selected measuring-range limit |
|
Threshold hysteresis |
15% |
|
Monitoring reaction time |
Adjustable 0.1–20 seconds |
|
Start-up suppression |
Adjustable 0.1–30 seconds |
|
Relay output |
1 changeover (C/O) auxiliary contact |
|
Relay-contact switching reference |
AC1: up to 5 A at 240 V AC; DC1: up to 5 A at 24 V DC; verify application category |
|
Analogue output |
Selectable 0–10 V DC or 4–20 mA in supported output mode |
|
Connection / terminal style |
Fixed screw terminals |
|
Dimensions (H × W × D) |
87 × 22.5 × 121 mm |
|
Operating ambient temperature |
0–55 °C; condensation not permitted |
|
Housing protection |
IP40; suitable protective enclosure required |
Choosing the right measuring range and output
“9 A” identifies the measurement-current version; it does not mean the C/O output contact can switch a 9 A load. Choose the input variant from the machine’s measured voltage, current arrangement and wiring scheme. Set the power range and the underload or overload threshold according to the real operating load, with sufficient tolerance for expected process variation.
Start-up suppression (ts) prevents initial acceleration or inrush-related behaviour from being treated as a normal running-load fault. Adjustable reaction time (tr) allows short load fluctuations to be handled separately from sustained deviations. The analogue signal can be routed to a compatible control or monitoring input after electrical compatibility is confirmed. Do not assume the device provides a certified emergency-stop safety function.
When a true-power monitoring relay is useful
The S1WP is relevant where load-dependent supervision helps engineers detect process abnormalities in suitable motors or electrical machinery. Possible examples include conveyor drive loading, pump load supervision and packaging-machine drives. Final suitability depends on whether a real-power threshold is a reliable indicator for the machine’s actual fault mode; a dedicated flow, level, temperature or guarding device may still be required.
Before replacing an existing S1WP, match Pilz part 890020 rather than assuming other variants are interchangeable. The 890010 has a different measuring-voltage range, the 890030 supports a higher measuring-voltage variant, and 18 A variants use a different measuring-current configuration. The 24 V DC control supply and fixed screw-terminal arrangement also need to match the panel.
Dhanbad ordering, GST and delivery
Indus MegaMart accepts orders and payment even when the requested quantity exceeds displayed stock or stock is zero. Under its standard policy, orders within available stock are delivered within 7 days; orders above stock, including zero-stock purchases, are delivered within 7–14 days. Delivery is conditional on the result of the destination-pincode check.
For company purchasing, confirm the exact 890020 part code, required units, present GST-inclusive amount, invoice information and destination pincode on the product listing. The generated purchase invoice includes the company’s GST number. Do not infer that a Dhanbad warehouse or local physical stock exists from online availability.
Frequently asked questions
1. What does Pilz S1WP 890020 measure?
It monitors true or real electrical power for suitable single- and three-phase systems. It can switch its changeover contact when measured power crosses a configured underload or overload threshold.
2. Is the 9 A specification the relay output-contact rating?
No. 9 A refers to the measuring-current variant. Pilz provides separate load-dependent ratings for the changeover relay contact, including up to 5 A under specified AC1/DC1 conditions.
3. Can 890020 replace Pilz 890010 or 890030?
Do not assume it can. Those parts differ by measuring-voltage version. Match the existing machine drawing, applied measurement voltage, measuring-current requirements and 24 V DC supply before choosing an alternative.
4. Does this monitoring relay perform an emergency-stop safety function?
It is specified for true-power monitoring and auxiliary threshold signalling. It should not be substituted for a dedicated, appropriately designed emergency-stop safety device.
5. Can its analogue signal connect to a PLC?
A compatible analogue input can use the selected 0–10 V or 4–20 mA signal when the control system, signal scaling, grounding and wiring are correctly engineered.
6. Why are start-up suppression and reaction time adjustable?
Start-up suppression avoids unwanted power alarms during machine acceleration; adjustable reaction time helps distinguish brief load changes from persistent out-of-range operation. Configure both for the actual machine and process.
7. Can I order for Dhanbad if stock is insufficient?
Yes. Indus MegaMart accepts orders above available stock, including zero-stock orders, under its stated order policy. Delivery for above-stock quantities is 7–14 days, subject to pincode serviceability.
Order Pilz S1WP 9A – 890020
Confirm the 24 V DC supply, 9 A measuring input, 0–415 V measuring version and exact part number. Check live price, GST, quantity and Dhanbad delivery details, then place the order through the exact Indus MegaMart product page.
Buy Pilz S1WP 9A True-Power Monitoring Relay 890020.