Pilz PNOZ s4.1 Safety Relay 24VDC (750124) in Deoghar
Order the Pilz PNOZ s4.1, article 750124, from Indus MegaMart for your Deoghar industrial procurement requirements. This standalone PNOZsigma safety relay operates on 24 V DC and provides three instantaneous normally open safety contacts, a normally closed auxiliary contact and a semiconductor signal output. Its 22.5 mm-wide housing and removable screw terminals make it a practical candidate for a correctly specified control-cabinet replacement or new safety circuit.
Check the current price, GST details, available quantity and delivery for your Deoghar pincode on the exact product listing. Pilz specifies one device per manufacturer packaging unit; verify the listed selling unit and required quantity before placing your order.
Check current price and buy Pilz 750124
Technical specifications of Pilz 750124
|
Parameter |
Specification |
|
Manufacturer / series |
Pilz / PNOZsigma |
|
Model / order number |
PNOZ s4.1 / 750124 |
|
GTIN |
4046548054217 |
|
Supply voltage |
24 V DC; tolerance −15%/+10%; residual ripple 20% |
|
Power consumption |
2.5 W |
|
Inputs / start |
2 inputs; single- or dual-channel configuration; manual, automatic or monitored start |
|
Safety relay outputs |
3 instantaneous normally open (NO) safety contacts |
|
Other outputs |
1 instantaneous NC auxiliary contact; 1 semiconductor signal output, 24 V DC / 20 mA (DC-12) |
|
Contact rating: AC-1 / DC-1 |
1.5 A at 240 V AC / 4 A at 24 V DC |
|
Contact rating: AC-15 / DC-13 |
0.6 A at 230 V AC / 0.4 A at 24 V DC (6 cycles/min) |
|
E-STOP release time |
10 ms typical, 20 ms maximum; power failure 40 ms typical, 80 ms maximum |
|
Installation |
DIN rail; plug-in screw terminals; any mounting position |
|
Size (H × W × D) / weight |
98 × 22.5 × 120 mm / 190 g net |
|
Operating environment |
−10 to +60°C; no condensation; housing IP40, terminals IP20, mounting enclosure IP54 |
|
Device safety data |
PL e / Category 4 / SIL 3, subject to documented conditions |
|
Approvals listed by Pilz |
CE, UKCA, CCC, cULus Listed, TÜV, EAC |
|
Manufacturer packaging |
1 unit per OEM packaging unit |
Choose the relay for the right safety function
Emergency stops, guards and light barriers
Where a machine requires safety-related interruption of an electrical circuit, the s4.1 can evaluate compatible emergency-stop devices, guard switches and light barriers. For example, a packaging machine may use the relay in its guard circuit, while a machine builder may use it in an emergency-stop circuit controlling external contactors. Pilz also specifies use in furnace safety applications in accordance with EN 50156-1. These are selection contexts, not confirmation of suitability for every machine or press.
Input and restart behaviour
The relay can be configured for single- or dual-channel input wiring, including configurations with or without cross-contact short detection. Choose the input arrangement and restart mode according to the safety assessment. Monitored start is available; automatic start must not be selected merely to simplify operation if unexpected restart could introduce a hazard. The LEDs help maintenance staff distinguish power, input, output, reset and fault states.
Contact loading and system limits
The DC-1 rating of 4 A is not a general rating for inductive loads. For a 24 V DC inductive control load, the specified DC-13 rating is 0.4 A at six switching cycles per minute. Check the applicable utilisation category, load characteristics, duty, contact protection and service-life conditions in the Pilz manual. The NC auxiliary and semiconductor signal outputs must not be treated as extra safety outputs. The relay release time is not the stopping time of the machine.
PL e, Category 4 and SIL 3 describe the device’s safety characteristics under the manufacturer’s conditions. Complete machine safety must be designed, calculated and validated by qualified personnel. Consult the operating manual for sensor compatibility, contact protection and installation requirements.
Pilz PNOZ s4.1 operating manual (21890-EN-15)
Confirm the correct s4.1 part number before ordering
The terminal style and supply voltage distinguish the four s4.1 articles. Compare your existing nameplate and approved electrical drawings rather than relying on the housing appearance or the number of contacts alone.
| Article |
Supply |
Connection |
|
750124 |
24 V DC |
Plug-in screw |
|
751124 (s4.1 C) |
24 V DC |
Plug-in spring-loaded |
|
750154 |
48–240 V AC/DC |
Plug-in screw |
|
751154 (s4.1 C) |
48–240 V AC/DC |
Plug-in spring-loaded |
For a screw-terminal replacement, Pilz lists spare terminal set 750004 separately. The relay can also connect to one compatible PNOZsigma contact expansion module via a connector; check the manufacturer’s compatibility and safety requirements. Neither accessory should be assumed to be part of the seller’s relay package. For other choices, browse the
Pilz range
Safety Relays category
Price, quantity and delivery for Deoghar procurement
Use your delivery address and pincode when checking the offer for 750124, whether you are purchasing for a control-panel workshop, machine maintenance team or a project site in Deoghar. Review the price including GST, the selling unit, required quantity and serviceability before payment. Indus MegaMart accepts orders and payment even when the requested quantity exceeds available stock. Under its ordering policy, orders within available stock are delivered within 7 days; orders exceeding available stock, including zero-stock orders, are delivered within 7–14 days. Confirm the applicable delivery details for your pincode on the product listing before payment.
For institutional purchase records, generated invoices contain the company’s GST number. Confirm the exact selling unit, applicable warranty and return conditions, and any volume-order requirements against the product offer. No Deoghar-specific inventory is assumed.
Frequently asked questions
1. Can Pilz 750124 operate from a 24 V AC supply?
No. Article 750124 is a 24 V DC supply version. A relay contact’s AC switching rating does not mean that the relay itself accepts AC power.
2. Are all four mechanical output contacts safety outputs?
No. Three normally open contacts perform the safety switching function. The normally closed contact is auxiliary. The separate semiconductor output is for signalling, not an additional safety output.
3. Does PNOZ s4.1 provide a timed stop output?
Its three safety contacts are instantaneous, not adjustable off-delay outputs. If the safety design needs delayed switching, select an appropriate device and validate the stop function.
4. Can I replace a PNOZ s4 or a PNOZ s4.1 C with article 750124?
Do not assume interchangeability. Check the exact article, supply, terminal technology, contact ratings, reset mode, input circuits and validated safety requirements. The 24 V DC s4.1 C article 751124 uses spring-loaded terminals.
5. Is 750124 suitable for safety light curtains?
Pilz supports light-barrier applications for the s4.1. The sensor output technology, test pulses and selected input configuration must match the operating manual. Have the complete protective function assessed before use.
6. Can this relay be used for furnace safety functions?
Pilz identifies furnace applications under EN 50156-1. That does not make it a complete burner-management system. A qualified engineer must assess the controls, valves and required safety function.
7. Does PL e or SIL 3 apply automatically to the entire machine?
No. Those are device-level safety characteristic data under stated conditions. The achieved level depends on all components, circuit design, diagnostics, loading and validation.
8. How do I purchase several units for a Deoghar maintenance order?
Open the exact 750124 product listing, review the current GST-inclusive offer and selling unit, select your required quantity and check the delivery pincode. The purchase invoice includes Indus MegaMart’s GST number. Confirm any warranty or return terms before ordering.
Ready to order? Match the article 750124 to your approved specification, then review the current offer and delivery details for your required quantity.
Buy Pilz PNOZ s4.1 (750124) for delivery to Deoghar