Buy Pilz PNOZ m EF SafetyNET Communication Module (772122) in Chhattisgarh
Order the Pilz PNOZ m EF SafetyNET communication module, part number 772122, from Indus MegaMart for your Chhattisgarh automation project or replacement requirement. It enables compatible PNOZmulti 2 controllers to exchange safety-related data using SafetyNET p RTFL. Each participating base unit requires its own expansion module, and a linear network can connect up to 16 subscribers. The module uses an external 24 V DC supply and two RJ45 interfaces. Check the current GST-inclusive price, selling unit, availability and delivery details on the product page before placing your order.
Buy Now — Pilz 772122
Network design: what the 772122 can connect
Use this module when compatible PNOZmulti 2 systems must share safety-related status across machine sections. The PNOZmulti Configurator defines up to 128 safe virtual inputs and 32 safe virtual outputs per module; the PNOZmulti Network Editor assigns those signals between projects. These are network variables, not physical I/O connections.
This RTFL line supports no intervening Ethernet switches, branches, or ring connections. Pilz specifies direct X2 Out-to-X1 In connections between adjacent subscribers, with a maximum of 100 m between two modules. Use straight-through, double-shielded industrial Ethernet cable and shielded RJ45 connectors meeting the 100BaseTX minimum Cat5 requirements. A qualified engineer must calculate the system response time and validate the complete safety application.
Technical specifications
|
Parameter |
Verified specification |
|
Brand / order no. / GTIN |
Pilz / 772122 / 4046548081220 |
|
Model / system |
PNOZ m EF SafetyNET / PNOZmulti 2 |
|
Communication |
SafetyNET p RTFL (Real Time Frame Line) |
|
Network / capacity |
Linear, up to 16 subscribers; one module per participating base unit |
|
Virtual I/O per module |
Up to 128 safe inputs and 32 safe outputs |
|
Ports |
2 × RJ45 (X1 In, X2 Out); galvanically isolated fieldbus |
|
Supply / external load |
24 V DC (−20%/+25%); 165 mA maximum continuous requirement; 4 W |
|
Internal supply / dissipation |
3.3 V DC via base, 60 mA / 0.2 W; max. module dissipation 4.5 W |
|
Cable / length |
Double-shielded straight-through industrial Ethernet, min. Cat5, 100BaseTX; max. 100 m between modules |
|
Mounting / terminals |
Horizontal 35 × 7.5 mm DIN rail; first safe module left of base; plug-in screw or spring terminals (accessories) |
|
Dimensions (H × W × D) / net mass |
101.4 × 45 × 110.4 mm / 180 g |
|
Operating / storage temperature |
0 to 60°C; 55°C without forced cabinet convection / −25 to 70°C |
|
Enclosure / humidity |
IP20 housing and terminals; cabinet at least IP54; 93% RH at 40°C, no condensation; max. altitude 2,000 m |
|
Component safety data |
PL e, Category 4, SIL 3; PFHD 1.54 × 10⁻⁹/h; PFD 5.66 × 10⁻⁵; mission time 20 years |
|
OEM listed approvals |
CE, UKCA, cULus Listed, TÜV, EAC |
The stated PL, Category and SIL values are component data. This does not establish the safety rating of the complete machine or networked safety function; all components, reaction times and programmed logic must be assessed together.
Before selecting or replacing the module
Pilz identifies PNOZ m B0 and PNOZ m B1 as suitable base-unit families. Match the actual base-unit firmware, module firmware and Configurator version to the manufacturer’s system-expansion and version documentation. The module occupies the first safe expansion position to the left of the base. Where HW:01 / FW:01.00 and HW:02 / FW:01.01 SafetyNET modules are mixed, Pilz requires the former to be the first module in the line for stable communication.
The PNOZ m EF Multi Link (772120) is an alternative for safe linking of two compatible controllers, not a drop-in replacement for a SafetyNET p RTFL network. Standard Ethernet/Modbus TCP or other fieldbus modules are selected for their own protocols; an RJ45 connector alone does not establish safety-network compatibility.
Browse safety controllers and modules
What to order alongside 772122
The manufacturer’s standard package specifies one module and a jumper. Pilz lists one item per OEM packaging unit; confirm Indus MegaMart’s actual selling unit before checkout. The terminal sets and cabling are separate accessories, not assumed to be supplied with the module.
| Pilz accessory |
Order no. |
|
Set 5 screw terminals |
750017 |
|
Set 5 spring terminals |
751017 |
|
SafetyNET p cable, Cat5e, per metre |
380000 |
|
Shielded RJ45 connector |
380401 |
|
Left-side connector plug, 10 pieces |
779260 |
Check the cabinet layout, existing connectors, compatible power supply and cable lengths when preparing the purchase list. Request confirmation of any accessory or software requirements not already included in your system.
Where this module fits
For example, two or more independently controlled packaging stations, conveyor cells or assembly machines may need to exchange permissive and interlock states. An appropriately configured SafetyNET p line can carry those signals between compatible controllers. Which machines stop, remain inhibited or restart is determined by the validated safety logic and risk assessment, not by the communication module alone.
Explore Pilz products
Electrical and industrial automation products
Ordering for a Chhattisgarh site
Use the exact 772122 product page to view the price, select your required quantity and check delivery for the receiving-site PIN code. Indus MegaMart accepts orders and payment even when the requested quantity exceeds available stock. For serviceable addresses, delivery follows the stock-based policy: within 7 days when the ordered quantity is within available stock, and within 7–14 days when it exceeds available stock, including zero stock.
Purchase invoices contain the company’s GST number. For a project purchase, confirm all module and accessory quantities against the bill of materials, along with the selling unit and applicable checkout terms. Verify delivery for the actual Chhattisgarh receiving address, rather than assuming stock is held locally.
Frequently asked questions
1. Can I use 772122 as a standalone safety controller?
No. It is an expansion module for a compatible PNOZmulti 2 base unit, not a controller that can execute the entire safety application independently.
2. Do the 128 inputs and 32 outputs refer to physical terminals?
No. They are safe virtual communication signals defined in the configuration software. Select separate physical I/O modules if required by the machine design.
3. Can I connect it through a standard Ethernet switch?
No. The SafetyNET p RTFL line requires direct links between subscribers. The two RJ45 ports do not provide a general-purpose switch function.
4. What happens if the receive connection is interrupted?
The base unit sets affected virtual inputs to zero, continues transferring output data and remains in RUN. The programmed safety application must define and validate the required response; network interruption alone does not guarantee every machine stops.
5. Are the terminal blocks and cables included?
Pilz specifies the expansion module and jumper as standard. Screw or spring terminals, network cables and connectors are separate accessory items. Confirm the merchant’s selling unit and any additional items before payment.
6. Can I replace an existing 772122 without changing its configuration?
Compare the actual hardware and firmware labels, controller version and saved project. A like-for-like part number does not remove the need to verify the network sequence and validate the safety function after replacement.
7. How do I order multiple modules for a Chhattisgarh installation?
Allow one module for each participating compatible base unit and include required spares and accessories in your bill of materials. Check the current price, selling unit and requested quantity on the exact product page, then enter the receiving-site pincode to check delivery.
Buy Now — View Pilz PNOZ m EF SafetyNET 772122 and complete your purchase