Pilz S1UM 827220 Monitoring Relay 24V DC in Bokaro
The Pilz S1UM 827220 is a single-phase voltage-monitoring relay for control cabinets that need to detect changes in AC or DC operating voltages. It is powered by 24 V DC and provides twelve selectable measuring range end values from 0.1 V to 500 V. Its adjustable response level, hysteresis and overvoltage reaction time let engineers tailor a voltage-dependent switching signal to the application. The compact 22.5 mm-wide unit has one auxiliary changeover contact. For Bokaro panel builders, maintenance teams and procurement departments, matching order number 827220 and the measurement circuit is the first step towards selecting the correct replacement or new installation.
Check the price and order the Pilz S1UM 827220
Check the GST-inclusive price and available quantity on the exact product listing. Confirm the selling unit and condition, select the required quantity and enter the delivery pincode for your Bokaro plant, workshop or project site. For a purchase order covering several panels, verify the total quantity and fulfilment commitment before paying.
Buy Now – Pilz S1UM 827220
Technical specifications
|
Parameter |
Specification |
|
Brand/family |
Pilz / PMDsrange S1UM |
|
Manufacturer order number / GTIN |
827220 / 4046548007695 |
|
Rated operating supply (UB) |
24 V DC; 1 W; tolerance −15% to +10% (manual) |
|
Measurement circuit (UM) |
Single-phase periodic AC or DC voltage; DC or 40–400 Hz AC |
|
Selectable range end values |
1 V input: 0.1, 0.2, 0.5, 1 V; 20 V input: 2, 4, 10, 20 V; 500 V input: 50, 100, 250, 500 V |
|
Threshold/return setting |
Response level 20–100% of selected full-scale range; hysteresis factor 0.60–0.95 of response level |
|
Reaction time |
0.1–10 s, adjustable for overvoltage response |
|
Output |
1 auxiliary changeover contact (11–12–14) |
|
Contact load (manual) |
AC-1: 0.1–5 A at 240 V; DC-1: 0.1–5 A at 24 V; AC-15: 2 A at 230 V; DC-13: 1.5 A at 24 V. Observe load-specific limits. |
|
Configuration/indicators |
Normally energised or de-energised; latching or non-latching; PWR and OUT LEDs |
|
Mounting/terminals |
DIN rail in protective enclosure; fixed screw terminals |
|
Dimensions / net weight |
87 × 22.5 × 121 mm (H × W × D); 120 g — exact OEM catalogue values |
|
Operating environment |
−15 to +55 °C; no condensation; housing IP40; mounting enclosure minimum IP54; terminals IP20 (manual) |
|
Approvals listed by Pilz |
CE, CCC, UKCA, cULus Listed |
|
Manufacturer packaging |
1 device per OEM packaging unit; seller quantity must be checked separately |
How the S1UM responds to voltage changes
An adjustable response threshold determines when a sustained rise in the measured voltage changes the relay state. The return point is a fraction of that threshold, set using hysteresis. This separation reduces repeated switching when the measured voltage fluctuates close to the response level. A selectable delay on overvoltage response allows brief excursions to be ignored where the application permits. Normally energised and de-energised modes change the output logic; a latched setting retains the changed state until the specified reset action. In non-latching mode the output can return automatically when the voltage crosses the return level.
Match the measuring circuit to the voltage
The supply and measuring circuit perform different jobs. A 24 V DC supply powers this relay, while a correctly selected measuring input supervises the voltage of interest. The standard 827220 is polarity-sensitive for DC measurements. The supply and measuring circuit must be galvanically isolated as required by Pilz for DC-powered units; failure to observe isolation can damage the device. A qualified engineer must select the input range and validate the wiring, load protection, threshold and timing using the operating manual.
Where the 827220 fits in industrial control panels
The S1UM can provide a threshold-dependent signal to a PLC input, an alarm circuit or a contactor control circuit, provided the interface and load are correctly designed. For example, a machine builder may use it to supervise a separate operating-voltage circuit and signal an abnormal rise or fall in voltage. A maintenance team may use the adjustable return point to avoid unnecessary switching during small voltage fluctuations. It does not measure motor current, independently determine phase imbalance or verify that an actuator actually moved. Those tasks need suitable dedicated devices.
Select the right monitoring relay, not just the right supply voltage
Use the S1UM when the requirement is a voltage threshold with a linked return point. If the circuit requires polarity-insensitive measurement, consider the separate S1UM UP version, 827225, only after checking compatibility. A three-phase monitoring requirement calls for a device specifically designed for that function. Browse more Pilz products and related controllers before finalising a replacement.
Explore Pilz products
Browse safety controllers and modules
Electrical and industrial automation products
Buying for Bokaro maintenance and project requirements
Indus MegaMart’s standard delivery policy is within 7 days when the ordered quantity is covered by available stock, or 7–14 days when it exceeds available stock, including zero stock. Orders and payments are accepted in either case. Confirm the actual delivery commitment and serviceability for the Bokaro pincode on the product listing before completing payment. For project procurement, confirm the exact order number, selling quantity and any documentation or applicable return terms. A manufacturer package contains one device; that does not establish the seller’s commercial pack. Purchase invoices contain the company GST number.
Frequently asked questions
1. Does the 827220 accept a 24 V AC supply?
Pilz specifies 24 V DC for the operating supply of part 827220. AC/DC in the measurement description refers to the voltage being supervised. Do not assume the abbreviated catalogue name establishes AC supply compatibility.
2. Is the S1UM 827220 the same as the 827225 UP version?
No. The 827225 UP variant has polarity-insensitive measuring inputs. The standard 827220 requires the correct DC measuring polarity; verify the order number and circuit documentation before substitution.
3. Can this relay provide two independently adjustable voltage thresholds?
No. Its response threshold and return point are linked by adjustable hysteresis, and it has one auxiliary changeover contact. Select a different monitoring architecture if independent high and low alarm outputs are required.
4. Can the S1UM replace an emergency-stop safety relay?
Do not assume so. The S1UM is intended for voltage supervision and has an auxiliary changeover output. It is not a direct substitute for a validated emergency-stop circuit or a dedicated three-phase phase-sequence monitor.
5. What should I check for a replacement in an existing panel?
Match the 827220 part number, 24 V DC operating supply, measuring range, polarity, output load rating, physical clearance and configured response behaviour. Have a qualified engineer verify isolation and wiring against the Pilz manual.
6. Can I order the relay when available stock is zero or insufficient?
Yes. Indus MegaMart accepts orders and payments even if the listed stock does not cover your requirement. Confirm the actual fulfillment timeline for the requested quantity and Bokaro delivery pincode before payment.
7. How can I check price, pack quantity and GST billing?
Use the exact 827220 listing to view the current GST-inclusive price. Pilz specifies one device per manufacturer packaging unit; confirm the seller’s selling unit, total quantity, condition and applicable warranty or return terms before placing the order. Purchase invoices contain the company GST number.
Order Pilz S1UM 827220 for your Bokaro requirement
Confirm the part number, voltage range and quantity, then check the current price and delivery details for your site on Indus MegaMart.
Buy Now – Pilz S1UM 827220 Monitoring Relay