Pilz 787584 PZE X4VP8 C Safety Relay 24V DC 4NO in Bokaro
Buy the Pilz 787584 PZE X4VP8 C for a machine safety circuit in Bokaro that needs additional time-delayed contacts. This 24 V DC contact expansion module provides four normally open safety outputs with selectable nominal delays of 5, 6, 7 or 8 seconds and removable spring-loaded terminals. It is intended for use with a compatible base safety relay that monitors the feedback loop, not as an independent emergency-stop or guard-monitoring relay.
Check the current GST-inclusive price, available quantity and selling unit on the product listing. Enter the delivery PIN code for your Bokaro site and confirm the required number of modules. Pilz identifies this part as a phase-out article, so verify availability for maintenance spares and project quantities before committing to a shutdown schedule.
Buy/check current price for Pilz 787584
Additional timed contacts for an existing safety circuit
The PZE X4VP8 C is an extension of a base safety circuit. When the base relay enables the expansion module, its output contacts close. After the control input is removed, the four outputs open following the selected off-delay. Feedback from the expansion module is evaluated by the base unit. That distinction matters if the bill of materials calls for a separate device to evaluate a guard or emergency-stop input.
Select the delay against the stopping sequence
All four outputs are delayed; there are no instantaneous safety contacts on this module. The timing accuracy specified by Pilz is −50%/+50%. An 8 s nominal setting may therefore take up to 12 s to open, and a fault can cause early opening. A safety engineer must assess the full stop sequence, including any time needed by downstream actuators. Do not place an immediate-stop function on these delayed contacts merely because the output count is correct.
Technical specifications — PZE X4VP8 C, 787584
|
Parameter |
Specification |
|
Brand/model/order number |
Pilz / PZE X4VP8 C / 787584 |
|
GTIN |
4046548008098 |
|
Product function |
Delayed safety contact expansion; base relay with feedback loop required |
|
Supply |
24 V DC; −15% / +10% tolerance; 2.5 W |
|
Control input |
Single channel; 24 V DC, 70 mA; no detection of shorts across contacts |
|
Outputs |
4 delayed NO safety contacts; no instantaneous safety outputs; 0 semiconductor outputs |
|
Selectable delay |
5, 6, 7 or 8 s; accuracy −50% / +50% |
|
Contact ratings |
AC-1: 5 A at 240 V AC; DC-1: 5 A at 24 V DC; AC-15: 5 A at 230 V AC; DC-13: 4 A at 24 V DC (6 cycles/min) |
|
Contact material |
AgSnO₂ with 0.2 µm gold layer |
|
Terminals |
Plug-in spring-loaded; flexible conductor 0.2–1.5 mm² |
|
Mounting / protection |
35 mm DIN rail; IP40 housing, IP20 terminals; cabinet at least IP54 |
|
Size (H × W × D) |
101 × 45 × 121 mm |
|
Ambient conditions |
−10 to +55 °C; no condensation; 93% RH at 40 °C |
|
Safety characteristic data |
PL d / Category 3 / SIL 2 for delayed contacts, subject to base unit and complete safety-function validation |
|
Net weight |
320 g |
|
Lifecycle |
Listed by Pilz as a phase-out article |
The stated ratings apply to the specified load categories; they are not a blanket current rating for every load or all simultaneous contacts. Apply the manufacturer’s load, fuse, thermal and service-life requirements. Pilz lists CCC, CE, EAC, TÜV, UKCA and cULus Listed approvals for this model. These do not certify an assembled machine or guarantee its achieved PL or SIL.
Select the right relay for panel maintenance or replacement
A maintenance engineer replacing a timed expansion module in an approved machine should compare its part number, contact timing, terminal connection and available panel space before ordering. For panel builders, the key requirement is a suitable safety base unit with feedback monitoring and a risk-assessed need for delayed switching. The expansion module cannot independently evaluate dual-channel safety inputs or detect shorts across input contacts.
Compare similar PZE models before ordering
|
Model / MPN |
Selection difference |
|
PZE X4VP8 C — 787584 |
4 delayed NO contacts, spring terminals, 45 mm wide; selectable nominal 5–8 s |
|
PZE X4VP8 — 777584 |
Plug-in screw terminals; 94 mm high. Confirm unit revision and delay configuration. |
|
PZE X4P C — 787585 |
Four instantaneous NO expansion contacts, spring terminals; 22.5 mm wide. Not a timing-equivalent replacement. |
|
PZE X4VP4 C — 787586 |
Nominal 1–4 s range; spring terminals, 45 mm width. Also identified as phase-out in the Pilz contact-expansion catalogue. |
Do not approve a substitution from matching voltage and contact count alone. Optional spring-loaded terminal sets 374290 (P1+P2) and 374291 (P3+P4) are separately listed in the product datasheet; do not assume they are included as spare sets. Have qualified personnel review the manufacturer’s operating manual, feedback and load requirements, then validate the complete safety function after replacement.
Compare other safety relays or browse Pilz components for a separately specified alternative.
Buying Pilz 787584 for delivery in Bokaro
For replacement spares, panel refurbishment or planned procurement, supply the delivery PIN code of the receiving facility and the exact required quantity. The Indus MegaMart stock and delivery policy allows order placement and payment even if the requested quantity exceeds available inventory. Orders within available stock have a delivery timeline of within 7 days; orders exceeding stock, including zero stock, have a 7–14 day timeline. Confirm PIN-code serviceability and actual fulfilment for this phase-out SKU on the product listing before scheduling work.
For purchase orders, use MPN 787584 to avoid confusing the C spring-terminal version with the screw-terminal variant. Check the current selling unit, GST-inclusive total, required documentation and applicable warranty or return terms before approving the purchase.
Frequently asked questions
1. Is Pilz 787584 a complete emergency-stop relay?
No. It adds delayed safety outputs to a compatible base safety relay with feedback monitoring. The base unit evaluates the safety request; the expansion module is not a substitute for it.
2. Can the delay be set to 8 seconds?
Yes. The selectable nominal settings are 5, 6, 7 and 8 seconds. Pilz specifies a timing tolerance of −50%/+50%; the complete stopping sequence must accommodate the worst-case timing.
3. Does this PZE module detect shorts across input contacts?
No. The 787584 uses single-channel control without cross-contact short detection. Evaluate the complete circuit and the diagnostic capability of its base unit.
4. What is the difference between 787584 and 777584?
787584 is the C version with plug-in spring-loaded terminals and a height of 101 mm. The 777584 has plug-in screw terminals and a height of 94 mm. Check the specific unit revision and timing before approving any substitution.
5. Is 787585 a direct replacement for 787584?
Do not treat it as a direct replacement. Although the PZE X4P C 787585 also provides four NO expansion contacts at 24 V DC, it is an instantaneous expansion model, not the selectable-delay X4VP8 C.
6. Can I use 787584 for a new machine safety design?
Pilz lists this model as a phase-out article. For a new design, review the manufacturer’s current portfolio and have a competent safety engineer approve the selection; for existing equipment, verify the exact part number and configuration.
7. Can I order the relay if the available quantity is zero?
Yes. Indus MegaMart accepts orders and payment even when stock is zero. The stated delivery policy is 7–14 days for orders exceeding available stock, including zero stock. Check your Bokaro delivery PIN code and confirm fulfilment for this phase-out model.
8. Will my purchase invoice include GST details?
Indus MegaMart purchase invoices contain the company’s GST number. Review the current GST-inclusive price, selling quantity and invoice requirements before confirming your order.
Order Pilz 787584 PZE X4VP8 C 24V DC 4NO from Indus MegaMart