Pilz PSWZ X1P 777951 Motor Standstill Monitoring Relay in Bikaner
Need the Pilz PSWZ X1P motor standstill monitoring relay, part 777951, for a machine-safety installation in Bikaner? This standalone relay evaluates the electrical voltage generated as a motor runs down and is used in safety circuits that must recognise a stopped motor before allowing a dependent action. It has a 24–240 V AC/DC supply, a 7.5–500 mV adjustable sensing threshold and two normally open safety contacts. Check the exact part number and your cabinet requirements, then use the Indus MegaMart product listing to review the current price and place your order.
Check the exact model and order for Bikaner
Confirm part number 777951, product type PSWZ X1P and the screw-terminal version before ordering. The current product price and GST breakup are shown on the Indus MegaMart product listing. Enter your Bikaner delivery pincode to review serviceability, choose the required quantity and continue to the exact product listing for checkout.
View current price and order Pilz 777951.
Verified technical specifications
|
Technical attribute |
Verified specification |
|
Brand / part number |
Pilz / 777951 |
|
Product / primary function |
PSWZ X1P standalone safety relay; motor standstill monitoring |
|
Relay supply voltage |
24–240 V AC/DC |
|
Adjustable motor voltage threshold |
7.5–500 mV (Uon); reset threshold Uoff = 2 × Uon |
|
Motor measurement circuit |
One- or two-channel; designed for motor residual-voltage evaluation |
|
Maximum measurement circuit voltage |
690 V (not the standstill detection threshold) |
|
Safety outputs |
2 instantaneous normally open (N/O) contacts |
|
Auxiliary output |
1 normally closed (N/C) auxiliary contact |
|
Semiconductor signalling outputs |
2 (for status / fault signalling) |
|
Terminals and mounting |
Plug-in screw terminals; DIN-rail installation |
|
Dimensions |
94 mm H × 45 mm W × 121 mm D |
|
Housing / terminal protection |
IP40 housing / IP20 terminals |
|
Ambient operating temperature |
–10°C to +55°C |
How motor standstill detection helps with machine safety
The PSWZ X1P measures the voltage generated by a motor during its rundown period. When the monitored signals meet the configured standstill conditions, its safety outputs can be incorporated into a properly designed interlock or release circuit. This addresses the safety requirement of not treating a coasting motor as stationary simply because the drive command has been switched off.
The relay is not a universal sensor-signal conditioner or a substitute for a machine safety assessment. Pilz specifies that standstill can be detected only in power-free measuring circuits; residual or induced voltages, and some drive-position-control arrangements, can prevent a safe standstill indication.
Selection and installation considerations
Distinguish the measuring threshold from the relay supply
The 7.5–500 mV range sets the response threshold for monitoring motor-generated voltage. It does not mean the relay needs a millivolt power supply; the relay itself operates from 24–240 V AC/DC. The separate maximum measuring-circuit voltage is 690 V.
Check contact types and model variants
Two N/O contacts are the safety outputs. The N/C contact and semiconductor outputs provide auxiliary or status information; do not treat them as extra safety contacts. Nearby PSWZ X1P models can have different thresholds or spring terminals, so use the complete 777951 part number rather than the series name alone.
Qualified commissioning and testing
Motor wiring, threshold setting, external contactor feedback, safety function design and commissioning must follow the official Pilz operating manual. The required monitoring performance depends on the complete machine circuit, not the relay alone.
Ordering, stock and delivery for Bikaner
Indus MegaMart accepts orders and payments even when the requested quantity exceeds the displayed available stock, including when the stock display is zero. Under its stated order policy, quantities within displayed stock are delivered within 7 days; quantities above stock, including zero-stock orders, are delivered within 7–14 days. Check delivery serviceability using your pincode and review the exact product listing before payment.
For planned maintenance or machine-building procurement, confirm the required quantity, terminal arrangement and documentation with your technical team. A GST-bearing purchase invoice is generated as part of the seller’s billing process.
Frequently asked questions
1. What does the Pilz PSWZ X1P 777951 detect?
It is designed for safety-related motor standstill detection by evaluating the voltage generated during motor rundown. It is not intended as a general-purpose pressure, level or sensor-transmitter monitoring relay.
2. Is 7.5–500 mV the supply voltage?
No. That range is the adjustable motor-voltage detection threshold. The relay supply is 24–240 V AC/DC.
3. How many safety contacts are available?
There are two normally open safety contacts. The additional normally closed auxiliary contact and two semiconductor outputs are not additional safety contacts.
4. Can I substitute PSWZ X1P part 777949 or 787951?
Do not substitute on series name alone. Part 777949 has a different lower detection threshold; part 787951 uses spring-loaded terminals. Confirm the motor conditions and connection method for part 777951.
5. What can prevent a safe standstill indication?
Pilz notes that residual or induced voltage and certain driven positioning conditions can inhibit standstill detection. Assess the actual motor circuit and follow the operating manual.
6. Can I order for Bikaner when the listed quantity is insufficient?
Yes. Indus MegaMart’s ordering policy accepts payment even when stock is insufficient or zero. Delivery is within 7–14 days for those quantities, subject to the delivery pincode check.
Buy Pilz PSWZ X1P 777951 for Bikaner
Verify the exact Pilz model, check the current price and GST on the product listing, enter your Bikaner pincode and proceed to purchase part 777951 through Indus MegaMart.
View Pilz PSWZ X1P 777951 — Buy Now.