Buy Pilz PNOZ mi1p 8 Digital Input Module (773400) in Bihar
For maintenance and procurement teams in Bihar, the Pilz PNOZ mi1p (773400) adds eight safe digital inputs to a compatible PNOZmulti Classic safety controller. It is intended for existing modular safety systems that need additional input channels or an exact-model replacement. The module accepts nominal 24 V DC field signals and receives its internal power through the base unit. Pilz lists this model as end-of-life and no longer available from the manufacturer, so verify the seller’s available quantity and required accessories before ordering.
Check the current price, GST breakdown, selling quantity and delivery serviceability for your Bihar PIN code on the product listing. Purchase invoices include the company GST number.
Buy Now – Pilz 773400
Technical specifications for Pilz 773400
|
Parameter |
Specification |
|
Manufacturer/model |
Pilz / PNOZ mi1p |
|
Order number / GTIN |
773400 / 4046548013047 |
|
System/version |
PNOZmulti Classic; standard (non-coated) |
|
Digital inputs |
8 safe inputs, I0–I7 |
|
Nominal input voltage |
24 V DC, EN 61131-2 Type 1 |
|
Input thresholds |
Low: −3 to +5 V DC; high: 15–30 V DC |
|
Internal module supply |
5 V DC through base unit; tolerance ±2% |
|
Power consumption |
2.5 W |
|
Input timing |
18 ms minimum pulse; 0.6 ms suppression; 4 ms maximum input delay |
|
Input isolation |
None |
|
Status indication |
LED |
|
Dimensions (W × H × D) |
22.5 × 94 × 121 mm |
|
Net weight |
120 g |
|
Mounting |
Horizontal on 35 × 7.5 mm DIN rail |
|
Connections |
Plug-in screw or spring-loaded terminals |
|
Ambient / storage temperature |
0 to 60 °C / −25 to 70 °C |
|
Cabinet cooling consideration |
55 °C limit when forced convection is off |
|
Humidity / altitude |
93% RH at 40 °C, no operating condensation; up to 2,000 m |
|
Protection |
IP20 housing and terminals; IP54 mounting area |
|
OEM listed approvals |
CE, UKCA, cULus Listed, KOSHA, EAC, TÜV |
How the eight-input module fits an existing safety system
This unit adds input channels, rather than acting as a standalone safety controller or a load-switching output module. The base controller evaluates the signals according to the configured safety logic. The module supports cross-short monitoring using system test pulses and provides LED status indication. The manual permits up to eight mi1p modules at the base unit, but the actual system expansion limits and permissible combinations must be checked for the installed base and Configurator version.
Typical input applications
Examples include emergency-stop circuits, guard-door switches, enabling devices, two-hand controls and compatible light curtains or scanners. The extra channels can help a maintenance team replace an existing damaged input extension or accommodate an approved change to a machine’s safety circuits. For example, an existing packaging machine may need extra channels for monitored access guards. The channel count must be calculated using the required single- or dual-channel circuit design, not merely the number of devices.
Compatibility and safety limitations
Confirm the exact base-unit order number, hardware and software revisions, approved safety project and input circuit before ordering. The standard 773400 is not the coated 773405 variant or a generic PLC input card. The nominal input voltage does not establish compatibility by itself. A qualified safety engineer must assess and validate the complete machine safety function; component approvals and input delay alone do not determine the total system response time or achieved performance level.
What to check before a replacement or expansion order
Match the article number and system generation on the existing module. Check cabinet clearance, horizontal mounting orientation and the environmental limits, particularly ventilation and condensation. The OEM documents a module and a jumper as the standard scope. Plug-in terminals are listed separately: spring-loaded set 783400 or screw set 793400. The optional standard bus terminator is 779110. Verify the actual seller pack, terminal requirement and condition of the offered item; do not assume a terminal kit is included. For an installed system, retain the validated project and arrange qualified recommissioning as necessary.
Because 773400 is a legacy component, consider the spare-parts requirement separately from a new system design. If planning an upgrade rather than replacing an existing part, consult Pilz for an approved migration path; a newer input module is not automatically a drop-in replacement.
Ordering and delivery for Bihar
Use the exact 773400 product listing to check the current price and choose your required quantity. Enter the destination PIN code to check delivery serviceability. Indus MegaMart accepts orders and payment even when the requested quantity is greater than available stock. Under the store’s delivery policy, orders within available stock are delivered within 7 days; orders exceeding available stock, including zero-stock orders, are delivered within 7–14 days, subject to serviceability. For a planned shutdown or multi-unit order, confirm stock, item condition, terminal requirements and expected fulfilment before scheduling the work. Verify warranty and return terms for this legacy item before purchasing.
For other components in the same system, browse the Pilz range or the safety controller category. Compare article numbers and compatibility rather than selecting by appearance.
Explore Pilz products
Browse safety controllers and modules
Electrical and industrial automation range
Frequently asked questions
1. Can 773400 operate without a base controller?
No. It is an expansion module, and its inputs are evaluated by a compatible PNOZmulti Classic base unit.
2. Is 773400 still manufactured or available from Pilz?
Pilz identifies this article as end-of-life and no longer available through its own product offering. For existing installations, establish available seller stock and the maintenance plan before ordering; ask Pilz about a suitable successor for migration.
3. Does 24 V DC refer to the module supply?
It is the nominal field-input voltage. The module receives 5 V DC internally through the base unit; the two voltage specifications describe different functions.
4. How many safety devices can I connect?
There are eight input channels, not necessarily eight independent safety functions. Dual-channel devices and diagnostic arrangements may consume multiple inputs. Use the approved circuit configuration for the actual allocation.
5. Are terminals included with the order?
The manufacturer’s documented scope lists the module and jumper, with terminal sets identified separately. Confirm the actual selling pack and whether terminals are supplied before placing your order.
6. Can I substitute the coated 773405 or a PNOZmulti 2 module?
Do not assume interchangeability. The 773405 is the coated variant and PNOZmulti 2 is a different generation. Confirm system expansion, base-unit and software compatibility with Pilz before approving a substitution.
7. Can I order more than the displayed stock?
Yes. Indus MegaMart accepts orders and payment even when the required quantity exceeds available stock or stock is zero. Under its delivery policy, quantities covered by stock are delivered within 7 days; quantities beyond stock are delivered within 7–14 days, subject to delivery serviceability.
Order Pilz PNOZ mi1p 773400 in Bihar
Review your required quantity, confirm the selling pack and check delivery details for your location before completing the purchase.