Pilz PNOZ e5.13p Safety Relay 24V DC (774191) in Bhavnagar
Looking for the screw-terminal Pilz PNOZ e5.13p (774191) for a machine safety panel in Bhavnagar? This 24 V DC PNOZelog unit is a standalone electronic safety relay with two instantaneous semiconductor safety outputs, built-in AND logic and automatic or monitored start. It is especially relevant when an existing control design uses separate emergency-stop and guard-monitoring circuits. Pilz lists this article as no longer available, so confirm the exact part and supply status before committing to a replacement order.
View price and order Pilz 774191
For a Bhavnagar delivery, check the current product price, GST basis, selling unit and requested quantity against the exact order number. Confirm the delivery pincode and replenishment for quantities beyond listed stock.
PNOZ e5.13p 774191 technical specifications
|
Parameter |
Specification |
|
Manufacturer/series |
Pilz / PNOZelog |
|
Model/order number |
PNOZ e5.13p / 774191 |
|
GTIN |
4046548011791 |
|
Supply |
24 V DC (19.2–30 V); 2 W at no load |
|
Safety outputs |
Two instantaneous semiconductor safety outputs (14, 24) |
|
Other outputs |
2 auxiliary semiconductor outputs; 1 test-pulse output |
|
Start/monitoring |
Automatic or monitored start; external contactor feedback; AND logic input |
|
Output utilisation |
DC-12; see load limits below |
|
Response |
35 ms maximum semiconductor-output response |
|
Mounting/enclosure |
35 mm DIN rail; IP54 cabinet minimum; housing IP40, terminals IP20 |
|
Dimensions / net weight |
94 × 22.5 × 121 mm (H × W × D); 130 g |
|
Connection |
Removable screw terminals; single flexible conductor 0.25–2.5 mm² |
|
Ambient limits |
−10 to +55 °C; 93% RH at 40 °C; no condensation |
|
Device approvals |
CE, UKCA, cULus Listed, TÜV, EAC |
How the two safety circuits work
The distinctive feature of this relay is the relationship between its two safety outputs. Output 14 responds to the first input circuit. Output 24 is AND-linked to the first circuit, the second input circuit and the applicable logic input. In a suitably designed machine, this allows a shared emergency-stop condition and an additional guard condition to be evaluated without treating both outputs as unrelated spare contacts.
Examples include a guarded assembly station, packaging machine or conveyor section with an existing PNOZelog safety circuit. Suitable emergency-stop buttons, safety gate switches, compatible position switches and OSSD light-grid signals can be evaluated as specified in the manufacturer's manual. The relay also supports feedback monitoring of external contactors. The POWER and channel LEDs help a technician identify operating states, but are not substitutes for fault diagnosis or safety validation.
Check output loading before replacing a relay
|
Safety outputs under load |
Supply at or below 26.5 V |
Supply above 26.5 V |
|
Both outputs |
1.5 A; 40 W |
1 A; 30 W |
|
One output |
2 A; 50 W |
1.5 A; 45 W |
These are manufacturer switching-capability limits, not AC contact ratings. The overall external semiconductor load is limited to 100 W; the auxiliary and test-pulse outputs are rated 24 V, 0.5 A. The off-state residual current can reach 0.5 mA. Consider the load type, test pulses, total power and any required suppression or interface components. The 2 A figure applies only to the stated single-output loading condition.
The module does not itself detect shorts across input contacts. The design must account for this limitation and the selected sensor’s capabilities. Auxiliary outputs must not be used as safety outputs. Pilz gives PL e (Category 4) characteristic data for the specified logic and two-channel paths, not an automatic machine-level rating. With a PDF-M proximity switch, the manual limits the achievable level to PL d (Category 3). Have a qualified safety engineer confirm the risk assessment, restart mode, stopping time, wiring and validation before commissioning.
Match the variant and accessories to your panel
|
Order number |
Terminal / height |
Selection note |
|
774191 |
Screw / 94 mm |
Exact item on this page |
|
784191 |
Spring-loaded / 101 mm |
Different termination; not a blind drop-in replacement |
Both variants are listed by Pilz as no longer available. For low-load test-pulse issues, the manual identifies optional filters 774195 (3–10 kΩ load range) and 774196 (10–30 kΩ). The product datasheet also lists screw-terminal set 374280 as an optional accessory. These accessories are not assumed to be included in the seller’s pack. Confirm the appropriate accessory and circuit design before purchase.
For other product families, browse Pilz products or compare safety relays within electrical and industrial automation. Do not substitute a relay solely on voltage or enclosure width.
Ordering Pilz 774191 for delivery in Bhavnagar
The manufacturer's packaging quantity is one device; confirm the selling unit and pack contents on the Indus MegaMart listing before placing an order. For maintenance spares or a project purchase, match the existing equipment label to 774191, reconcile the required quantity, and check the GST-inclusive amount. Purchase invoices contain the company GST number.
Indus MegaMart’s general ordering policy accepts orders and payment even if the required quantity exceeds available stock. For serviceable destinations, orders within available stock have a delivery window of up to 7 days; orders exceeding available stock, including zero stock, have a general window of 7–14 days. For this discontinued article, confirm actual replenishment and the delivery commitment for your Bhavnagar delivery pincode before payment. Do not assume the displayed availability represents Bhavnagar warehouse stock. Confirm condition, warranty and return terms for the exact offer.
Frequently asked questions
1. Are the two safety outputs dry relay contacts?
No. 774191 uses semiconductor safety outputs, not isolated mechanical NO contacts. Check the receiving device and DC load characteristics before replacing a contact-output relay.
2. Does this model provide delayed safety outputs?
The operating manual identifies both safety outputs as instantaneous, with a maximum 35 ms response time. The overall stopping time still depends on the complete machine safety function; do not select this model as an adjustable off-delay relay.
3. Can I use the auxiliary outputs for emergency-stop switching?
No. Y32 and Y33 are status outputs, for example to a PLC or display. Use the designated safety outputs only within the validated safety circuit.
4. Is the PNOZ e5.13p C the same part?
No. Order number 784191 has spring-loaded terminals and is 101 mm high; 774191 has plug-in screw terminals and is 94 mm high. Do not substitute without checking wiring, fit and the validated safety design.
5. Can this unit monitor an OSSD light grid?
The manual supports suitable light-grid output signal switching devices. Confirm the exact sensor, signal behaviour, input circuit and required safety level before selection.
6. Is 774191 still manufactured or offered by Pilz?
Pilz lists this article as no longer available. Existing channel stock may still be offered. Confirm condition, exact quantity and replenishment before committing a maintenance or project order; ask Pilz about a verified successor if necessary.
7. Can I order if the displayed stock is zero?
Indus MegaMart accepts orders and payment when stock is insufficient, including zero stock. Because this is a discontinued OEM item, confirm that the requested quantity can actually be supplied and check the applicable delivery commitment before payment.
8. What should a purchase team confirm for a spare relay?
Match 774191 to the installed part and approved drawings. Confirm the seller’s sale unit, GST-inclusive total, delivery pincode, condition and applicable warranty or return terms before placing the order.
Check availability and buy Pilz PNOZ e5.13p 774191 on Indus MegaMart