Buy Fluke 114 Digital Multimeter in Belgaum
The Fluke 114 Digital Multimeter is a compact True RMS electrical meter for technicians who need to establish whether the expected voltage is present, verify connections and narrow down faults. For electrical contractors, facility maintenance teams and industrial service engineers in Belgaum, its automatic AC/DC voltage selection, separate AC and DC ranges and low-impedance Auto-V LoZ mode offer a practical combination for routine troubleshooting. It is rated CAT III 600 V and measures resistance up to 40 MΩ.
Check the current GST-inclusive price, select the required model and order quantity, and check delivery to your Belgaum pincode on the product page. The 114 is intended for voltage, resistance and continuity measurements rather than direct current or advanced electronic component testing.
Buy Now – Fluke 114 Digital Multimeter
Choosing the right voltage mode
A voltage may appear on a disconnected conductor through capacitive coupling to nearby live wiring. A high-impedance meter can register this small induced signal. The Fluke 114 offers a separate Auto-V LoZ mode with a nominal input impedance of about 3 kΩ, which helps suppress ghost-voltage readings and automatically distinguishes AC from DC voltage. This is especially helpful when the purchasing requirement is routine go/no-go voltage assessment.
For sensitive electronics or circuits that should not be loaded by the measuring instrument, the standard voltage ranges are a better starting point when appropriate. The nominal input impedance is above 5 MΩ for AC voltage and above 10 MΩ for DC voltage. LoZ is not appropriate for every circuit; its loading can alter circuit behaviour or trip protective devices. Follow the manufacturer's instructions and your site safety procedure.
The 6000-count display, illuminated screen and HOLD function aid reading in difficult viewing positions. MIN/MAX/AVG recording is useful for observing changes during troubleshooting, but is not a substitute for a waveform recorder or power-quality analyser.
Fluke 114 technical specifications
Measurement ranges and resolution
|
Function |
Full-scale range |
Resolution |
Accuracy ± (% reading + counts) |
|
DC voltage |
6.000 / 60.00 / 600.0 V |
0.001 / 0.01 / 0.1 V |
0.5% + 2 |
|
AC voltage (True RMS) |
6.000 / 60.00 / 600.0 V |
0.001 / 0.01 / 0.1 V |
1.0% + 3; 2.0% + 3 at higher band |
|
DC millivolts |
600.0 mV |
0.1 mV |
0.5% + 2 |
|
AC millivolts (True RMS) |
600.0 mV |
0.1 mV |
1.0% + 3; 2.0% + 3 at higher band |
|
Auto-V LoZ |
600.0 V |
0.1 V |
2.0% + 3; 4.0% + 3 at higher band |
|
Resistance |
600.0 Ω; 6.000 / 60.00 / 600.0 kΩ; 6.000 / 40.00 MΩ |
0.1 Ω; 0.001 / 0.01 / 0.1 kΩ; 0.001 / 0.01 MΩ |
0.9% + 2 at 600 Ω; 0.9% + 1 intermediate; 5.0% + 2 at 40 MΩ |
|
Continuity |
600 Ω |
1 Ω |
Beeper on below 20 Ω, off above 250 Ω; detects events ≥500 µs |
AC voltage and AC mV accuracy: 45–500 Hz at the first stated accuracy; above 500 Hz to 1 kHz at the second. Auto-V LoZ has the first accuracy for DC and 45–500 Hz, and the second above 500 Hz to 1 kHz. The normal AC ranges are specified from 1% to 100% of range; Auto-V LoZ from 0 V. Accuracy is specified for one year following calibration at 18–28 °C and 0–90% relative humidity.
Instrument and environmental specifications
|
Parameter |
Specification |
|
Model and class |
Fluke 114; handheld electrical True RMS DMM |
|
Maximum terminal-to-earth voltage |
600 V |
|
Safety |
CAT III 600 V; IEC 61010-1 pollution degree 2; IEC 61010-2-033 |
|
Input impedance (nominal) |
AC V >5 MΩ; DC V >10 MΩ; Auto-V LoZ approx. 3 kΩ |
|
Display |
6000 counts, 4 updates/s; 33-segment bar graph, 32 updates/s; white LED backlight |
|
Controls |
Auto/manual ranging, HOLD, MIN/MAX/AVG recording |
|
Battery |
9 V alkaline IEC 6LR61; typical 400 hours without backlight |
|
Dimensions / weight |
167 × 84 × 46 mm; 550 g (manufacturer product-page listing) |
|
Temperature |
Operating −10 to +50 °C; storage −40 to +60 °C |
|
Altitude / humidity |
Operating up to 2000 m; 95% RH to 30 °C, 75% to 40 °C, 45% to 50 °C |
|
Ingress protection |
IP42, non-operating only |
Suitable applications and measurement limits
The Fluke 114 fits routine voltage verification in commercial building distribution panels, lighting and control circuits, industrial maintenance and HVAC electrical supply checks. Its continuity and resistance settings help qualified technicians evaluate disconnected wiring, switches and connections. It does not include direct AC/DC current, frequency, capacitance, diode or non-contact voltage functions. If a job calls for compressor current, motor capacitance or electronic component checks, choose a suitable clamp meter or multimeter with the required function. The 115 adds direct current, frequency, capacitance and diode testing; the 117 also offers Auto-V LoZ and non-contact AC voltage detection.
Use only within CAT III 600 V and the applicable measurement setup limits; it is not a CAT IV meter. Use appropriately rated test leads and accessories, inspect them before use, and follow qualified electrical work practices. De-energize and discharge circuits before resistance or continuity testing. The IP42 rating applies only when not operating, and the manual specifies Class A EMC equipment; do not assume suitability for wet operation or residential electromagnetic environments.
Standard package and buying checks
Fluke’s standard 114 package lists the instrument, one pair of test leads (TL75 in the product datasheet), protective holster, installed 9 V battery and user documentation. The ToolPak magnetic hanger is optional, not a standard inclusion. Confirm the actual supplied package, sale unit, warranty handling and any calibration or accessory requirements before placing an institutional or maintenance-toolkit order.
Price, GST and delivery in Belgaum
Use the current product listing to confirm the price including GST, quantity and delivery serviceability. Indus MegaMart purchase invoices contain the company GST number. For multiple instruments, select the required quantity and confirm the exact package and procurement requirements before payment.
Under Indus MegaMart’s order policy, when the ordered quantity is within available stock, delivery is within 7 days. When the quantity exceeds available stock, including when stock is zero, orders and payment are still accepted and delivery takes 7–14 days. Check your Belgaum delivery pincode for serviceability; these timelines do not imply stock held in Belgaum.
Explore other digital multimeters
Browse Fluke instruments
Explore test and measurement instruments
Frequently asked questions
1. Can the Fluke 114 measure amperage or frequency?
It has no dedicated AC/DC current input or stand-alone Hz reading function. Frequency bands in its AC-voltage accuracy specifications describe the signal being measured, not a frequency-measurement mode. Choose an appropriately rated meter with those functions if required.
2. Does the Fluke 114 measure capacitance or test diodes?
No. The 114 is designed around voltage, resistance and continuity. For capacitor or diode checks, select a meter such as the Fluke 115 or 117 if its measurement range and safety category suit the job.
3. What is the difference between the Fluke 114 and 113?
The 114 provides separate AC/DC voltage and millivolt ranges plus Auto-V LoZ, with resistance up to 40 MΩ and CAT III 600 V. The 113 is a utility meter with VCHEK, diode and capacitance functions and CAT IV 600 V. Select by functions and measurement category rather than model number alone.
4. Is a calibration certificate included?
A calibration certificate is not listed in the standard Fluke 114 package. If your purchase order requires traceable calibration documentation, confirm the arrangement before ordering.
5. What warranty applies to the Fluke 114?
Fluke specifies a three-year limited warranty against defects in material and workmanship, with exclusions such as misuse and disposable batteries. Confirm the applicable seller warranty handling and return terms before purchase.
6. Can I order the Fluke 114 if stock is zero?
Yes. Indus MegaMart accepts orders and payment even when available stock is insufficient or zero. The delivery window for these orders is 7–14 days, subject to delivery serviceability.
Order the Fluke 114 for your Belgaum requirements
Select the exact Fluke 114 model, review the current price and quantity, and proceed to purchase from Indus MegaMart after checking delivery to your site.
Buy Now – Fluke 114 Digital Multimeter