Fluke 15B MAX Digital Multimeter with TL75 Test Leads - Kit 01 in Bangalore
Order the Fluke 15B MAX-01 digital multimeter with TL75 test leads from Indus MegaMart for electrical maintenance and electronics testing requirements in Bangalore. This configuration combines a handheld meter, a backlit 6000-count display and an input-connection warning system with general-purpose probes. It measures AC and DC voltage and current, resistance and capacitance, and supports diode and continuity checks. For maintenance teams equipping technicians with a common meter model, Kit 01 provides a clearly defined starting configuration.
Price, kit selection and ordering in Bangalore
Open the exact Kit 01 product listing to review the current price including GST, choose your required quantity and enter your Bangalore delivery pincode. Check the selling unit, package details and applicable warranty or return terms before placing the order.
Buy Now – Fluke 15B MAX Kit 01 with TL75
What comes with the Fluke 15B MAX-01?
The manufacturer’s standard 15B MAX-01/CN configuration consists of the multimeter, one TL75 red-and-black test lead set with two protective caps, and two AA batteries. Kit 01 is intended for general electrical measurements; it is not the combined TL75 and TL31 package. Confirm the commercial pack shown on the product listing when purchasing multiple kits.
Technical specifications
|
Measurement or feature |
Fluke 15B MAX |
|
AC/DC voltage ranges |
6 / 60 / 600 / 1000 V; 600 mV separate range |
|
Voltage safety limits |
CAT III 600 V; 600 V terminal-to-earth; 1000 V V-to-COM differential maximum |
|
AC voltage accuracy |
±(1.0% + 3 digits), 40–500 Hz |
|
DC voltage accuracy |
±(0.5% + 3 digits) |
|
AC/DC current |
400 / 4000 µA; 40 / 400 mA; 4 / 10 A |
|
Current accuracy |
±(1.5% + 3 digits); AC 40–400 Hz |
|
Resistance |
400 Ω to 40 MΩ |
|
Capacitance |
40 nF to 2000 µF |
|
Diode / continuity |
2 V diode range; 70 Ω continuity threshold |
|
Display |
6000 counts, 3 updates/s; backlight |
|
Power |
2 AA (IEC LR6); minimum 500 hours |
|
Dimensions / weight |
183 × 91 × 49.5 mm; 455 g |
|
Environment |
0–40 °C operating; IP40; operating altitude 2000 m |
|
Current input fuses |
440 mA and 11 A, 1000 V fast-blow; Fluke specified parts only |
|
Dedicated frequency / temperature / duty cycle |
Not available on 15B MAX |
Accuracy values are manufacturer specifications under stated calibration and environmental conditions (18–28 °C and 0–75% RH). Consult the instrument manual for measurement limits and operating instructions.
Where Kit 01 fits your maintenance requirements
Electrical panels and equipment maintenance
The voltage and resistance functions help qualified technicians inspect supply and control circuits within the instrument’s ratings. Continuity and diode functions support troubleshooting of isolated wiring and components. The input warning helps identify a misplaced lead before a measurement is attempted.
Electronics and component checks
The millivolt, microamp and milliamp ranges extend the meter’s usefulness to electronics work, while capacitance measurements help assess isolated, discharged capacitors. For closely spaced PCB terminals, the TL31 extra-slim option may be a better choice than general-purpose TL75 probes.
Selecting the right model and safety rating
Choose Kit 01 for general-purpose probes. Choose Kit 02 if narrow probe access is the priority, or the combined kit if both lead styles are required. If frequency, duty cycle or temperature measurements are essential, consider the 17B MAX. For distorted AC waveforms, select a meter explicitly specified for True RMS rather than assuming the 15B MAX has that capability.
The TL75 lead set has a CAT II 1000 V, 10 A rating without protective caps; with caps fitted its category ratings are CAT III 1000 V and CAT IV 600 V. These accessory ratings do not increase the meter’s own CAT III 600 V limit. Follow the lowest applicable rating of the meter, leads and accessories, and use the instrument only within its specified limits. IP40 does not indicate water protection.
Delivery and procurement for Bangalore buyers
Indus MegaMart accepts orders and payments even if current stock is insufficient. For quantities within available stock, the standard delivery window is within 7 days; quantities exceeding stock, including zero-stock orders, follow a 7–14 day window. Check delivery against your destination pincode. For a maintenance team purchase, confirm the total number of Kit 01 units and tax amount before checkout.
Explore other Fluke instruments
Compare digital multimeters
Browse test and measurement instruments
Frequently asked questions
1. Is Kit 01 the same as the TL31 kit?
No. Kit 01 is the TL75 configuration. Kit 02 uses TL31 extra-slim leads, while the combined kit includes both lead types.
2. Can the meter be used for 1000 V CAT III circuits?
No. The maximum differential voltage range is not a CAT III 1000 V safety rating. The meter is rated CAT III 600 V, with a 600 V terminal-to-earth limit.
3. Does the 15B MAX measure frequency or temperature?
No. Dedicated frequency, temperature and duty-cycle functions are available on the 17B MAX, not the 15B MAX.
4. What does Input Alert do?
It gives an audible and visual warning when the lead connection and selected measurement function are incompatible. It does not replace correct lead placement or electrical safety procedures.
5. Can I order more kits than the available stock?
Yes. Indus MegaMart accepts orders and payment even when the requested quantity exceeds stock, including zero stock. The applicable delivery window is 7–14 days.
6. Is a GST invoice provided?
Purchase invoices generated by Indus MegaMart contain the company GST number. Review the applicable tax amount and order details before payment.
Buy Fluke 15B MAX Digital Multimeter with TL75 Test Leads – Kit 01