Pilz PZA 30 774030 Safety Timer Relay in Asansol - 24V DC, 3-30 s
Order the Pilz PZA 30 safety timer relay, manufacturer part number 774030, for a Asansol industrial control or machine-safety project through Indus MegaMart. This standalone 24 V DC device provides an adjustable delay-on-energisation function with 12 selectable settings from 3 to 30 seconds, one normally open delayed safety contact and two normally closed delayed auxiliary contacts. It uses single-channel wiring, a monitored feedback loop and integrated screw terminals. For maintenance replacements or new control-panel designs, check the exact 774030 part number, current price, tax details and destination pincode before purchasing.
Check Price, GST and Purchase Pilz 774030
Use the Pilz 774030 product page to review the current selling price, applicable GST, order quantity and checkout options. The same model should appear throughout the purchase process; the PZA 600 (774028) is a different timer and should not be substituted simply because both use 24 V DC.
Check the current price and buy Pilz PZA 30 (774030)
Verified Pilz PZA 30 (774030) Specifications
|
Specification |
Detail |
|
Manufacturer / model |
Pilz / PZA 30 |
|
Manufacturer part number |
774030 |
|
Manufacturer GTIN |
4046548012507 |
|
Product function |
Delay-on-energisation safety timer relay |
|
Nominal supply |
24 V DC |
|
DC power consumption |
3 W |
|
Timing selection |
12 stages, from 3 to 30 seconds |
|
Selectable times |
3, 4, 5, 7, 9, 12, 15, 18, 21, 24, 27 and 30 s |
|
Input configuration |
Single-channel |
|
Delayed safety contacts |
1 normally open (N/O) |
|
Delayed auxiliary contacts |
2 normally closed (N/C) |
|
Feedback loop |
Feedback-loop monitoring |
|
Connection |
Integrated fixed screw terminals |
|
Width × height × depth |
45 × 87 × 121 mm |
|
Operating ambient temperature |
−10 °C to +55 °C |
|
Housing protection |
IP40 |
Contact suitability depends on the load category and the complete circuit. Pilz lists safety-contact switching data including AC-1 up to 240 V / 6 A and DC-1 at 24 V / 6 A; inductive loads must be assessed against their applicable AC-15 or DC-13 ratings. Engineering design, protective devices and installation must follow the manufacturer instructions.
Why the 3–30 Second On-Delay Matters
The PZA 30 is selected when a validated control design requires an enabling output only after the chosen delay-on-energisation period. Its adjustable range makes it relevant to defined machine control sequences and interlocked start conditions where a controlled waiting period is required. The feedback circuit forms part of the monitoring arrangement, so correct wiring is essential. The PZA 30 should not be described as a universal emergency-stop, safety-gate or two-hand-control monitor merely because it is classified among safety relays.
Delay-on-energisation is not delay-on-de-energisation
On-delay describes when the contacts change after the relevant energising conditions are met. It is different from a relay designed to hold outputs after de-energisation. The exact required safety function and response on power removal must be assessed against the Pilz circuit diagrams rather than inferred from the word “timer”.
Choose the Correct PZA Timing Variant
|
Pilz product |
OEM part number |
Selectable timing range |
|
PZA 30 / 24 V DC |
774030 |
3–30 seconds |
|
PZA 300 / 24 V DC |
774029 |
30–300 seconds |
|
PZA 600 / 24 V DC |
774028 |
60–600 seconds |
These are different manufacturer part numbers and timing ranges. A purchasing decision should match both the control voltage and the required on-delay interval; identical-looking terminal layouts or similar descriptions do not establish interchangeability.
Selection Checks for Maintenance and OEM Buyers
- Match the label on the installed relay to PZA 30 and manufacturer part number 774030.
- Confirm a 24 V DC power supply, the required 3–30 second delay range and a single-channel input design.
- Check that the circuit uses one delayed N/O safety contact and two delayed N/C auxiliary contacts; do not treat an auxiliary contact as an additional safety output.
- Validate feedback-loop wiring, contact load, external protection, mounting space and the full safety function with the responsible engineer.
- Check the seller’s current sale-unit and quantity display before purchase; do not assume manufacturer packaging equals a merchant multipack.
Asansol Ordering and Delivery
Buyers in Asansol can enter their destination pincode on Indus MegaMart to check delivery details and then place the order for the exact 774030 model. Orders and payment remain possible even when the requested quantity exceeds available stock. When the order quantity is within the available stock, delivery is within 7 days. If the quantity exceeds available stock, including when stock is zero, delivery is within 7–14 days. Review the current selling price and applicable GST for the selected quantity at checkout.
If you are buying for a plant shutdown, maintenance replacement or OEM control-panel project, confirm the required quantity and technical fit before finalising the order. A purchase invoice includes the seller’s GST number.
Explore the Pilz safety-relay range
Browse Pilz products at Indus MegaMart
Frequently Asked Questions
1. What is Pilz PZA 30 774030 used for?
It is a 24 V DC delay-on-energisation safety timer relay with 12 selectable time settings between 3 and 30 seconds, used where the engineered safety/control function requires a supervised delayed enabling sequence.
2. Is the PZA 30 774030 the same as the PZA 600 774028?
No. The 774030 PZA 30 has a 3–30 second range. The 774028 PZA 600 has a 60–600 second range. Verify the required interval before ordering.
3. How many contacts are provided?
Pilz specifies one delayed normally open safety contact and two delayed normally closed auxiliary contacts. The auxiliary contacts must not be counted as extra safety outputs.
4. Does the PZA 30 use AC or DC supply?
Manufacturer part number 774030 requires 24 V DC. Other PZA variants can use different supplies, so check the precise part number.
5. Can I use the PZA 30 as a direct replacement for any emergency-stop safety relay?
No. It is primarily a delay-on-energisation timing device. A qualified engineer should confirm the installed safety function, timing requirement, wiring, contact load and compliance needs before replacing another relay.
6. What should I check about the order quantity and GST?
Confirm the current selling unit, quantity selection and GST breakdown on the exact Pilz 774030 product page. Do not assume a price shown for another PZA model applies to this part.
7. Can I place an order if available stock is zero?
Yes. Indus MegaMart accepts orders and payment even if the available stock is zero. In that case the stated delivery period is within 7–14 days, subject to the destination delivery check.
8. How do I confirm delivery to my Asansol address?
Enter the destination pincode on Indus MegaMart and review the resulting delivery details before checkout. The model number and selected quantity should remain the same when you proceed to purchase.
Buy Pilz PZA 30 774030 for Your Asansol Requirement
Choose the exact Pilz PZA 30/24VDC 1 N/O 2 N/C, part number 774030, for your approved on-delay application. Review the current price, GST and pincode delivery information and complete your purchase through the matching Indus MegaMart product page.
Buy Pilz PZA 30 Safety Timer Relay 774030