Pilz 751109 PNOZ s9 C Safety Relay 24 V DC in Arunachal Pradesh
Buy the Pilz 751109 PNOZ s9 C from Indus MegaMart for control panel projects and maintenance requirements in Arunachal Pradesh. This PNOZsigma safety timer and contact expansion relay operates on 24 V DC and provides three timed normally open safety contacts plus one timed normally closed auxiliary contact. Its selectable timing range of 0.04–300 seconds and narrow 17.5 mm housing make it useful where a validated machine safety circuit requires timed switching or additional contacts.
Match the spring-terminal order number 751109 to your bill of materials. Review the current GST-inclusive price, selling unit and quantity on the exact product listing, then check delivery using your Arunachal Pradesh receiving pincode.
Buy Now – Pilz 751109
Technical specifications of Pilz PNOZ s9 C 751109
|
Specification |
Detail |
|
Brand / series / model |
Pilz / PNOZsigma / PNOZ s9 C |
|
Order number / GTIN |
751109 / 4046548025491 |
|
Relay function |
Safety timer and contact expansion |
|
Supply / power |
24 V DC; −20% to +20%; 2 W |
|
Safety contacts |
3 normally open (NO), timed; positive-guided relay outputs |
|
Auxiliary contact |
1 normally closed (NC), timed; not a safety output |
|
Timing |
Selectable 0.04–300 s; normal tolerance ±1% plus ±20 ms; fault tolerance ±15% plus ±20 ms |
|
Modes |
Instantaneous, delayed de-energisation, delayed energisation, pulse; retriggerable off-delay only with PNOZsigma base or standalone |
|
Input architecture |
Single-channel with other base units or standalone; dual-channel via PNOZsigma connector |
|
Safety contact ratings |
AC-1: 6 A at 240 V AC; DC-1: 6 A at 24 V DC; AC-15: 5 A at 230 V AC; DC-13: 5 A at 24 V DC (6 cycles/min) |
|
Connection / mounting |
Plug-in spring-loaded terminals; DIN rail; 0.2–2.5 mm² flexible conductors |
|
Dimensions (H × W × D) / weight |
100 × 17.5 × 120 mm / 175 g net |
|
Operating conditions |
−10 to +55 °C; no condensation; housing IP40, terminals IP20, cabinet IP54 |
|
Manufacturer approvals |
CE, CCC, EAC, KOSHA, TÜV, UKCA, cULus Listed |
|
OEM packaging |
One relay per manufacturer packaging unit |
Selecting a timing function for the machine safety circuit
The s9 C is intended to extend the output contacts of a suitable safety-related base unit or to implement a permitted timing function. In a controlled-stop design, the timing relay may coordinate a delayed safety output with the upstream safety controller. It does not detect actual zero speed or determine that a guard can safely unlock by itself.
Delayed switching and pulse operation
A delay before energisation can support a validated delayed-release sequence. A delay before de-energisation can support a controlled stopping sequence. A pulse function is available for limited movement applications where the safety design permits it. The retriggerable off-delay behaviour differs from the non-retriggerable mode and is limited to standalone use or use with a PNOZsigma base unit. Use the manufacturer’s timing diagrams to confirm the required behaviour and safe response to faults.
Expansion with a suitable safety base unit
Pilz permits contact expansion with safety relays that monitor a feedback loop. A PNOZsigma base can provide a dual-channel connection through the specified connector; other base-unit arrangements or standalone operation use a single input channel. Suitable applications may include approved safety circuits on movable guards or controlled-stop systems in packaging equipment, assembly machinery and conveyor installations. These examples require a machine-specific safety assessment; they are not pre-validated designs.
What to confirm before replacing or specifying 751109
For an existing panel, check the nameplate, spring-loaded connections, enclosure clearance, base relay, feedback loop and required operating mode. The screw-terminal PNOZ s9 750109 and coated 751189 are distinct order numbers, not automatic substitutes. If the design needs immediate safety contacts in combination with timed ones, more outputs or actual speed monitoring, select the correct device and architecture rather than relying on a similar family name.
The 6 A contact rating applies to specified AC-1 and DC-1 loads, not every inductive or high-inrush load. Review the applicable AC-15 or DC-13 limit, switching rate, load-life curve, protective devices and simultaneous-contact loading. A qualified machine-safety engineer must validate the complete safety function; the achievable performance level depends on the base unit and the rest of the circuit. The auxiliary NC contact is not a safety output.
Compare other safety relays
Explore Pilz products
Browse safety automation components
Price, quantity and delivery for Arunachal Pradesh procurement
For a maintenance spare or a multi-panel project, use part number 751109 when specifying the required quantity. The product listing provides the price including GST, and purchase invoices include the company GST number. Check the seller’s selling unit, quantity and final amount before checkout. For bulk orders, use the product enquiry option if you need quantity or commercial clarification. Confirm applicable warranty and return terms before payment.
Enter the pincode for your Arunachal Pradesh factory, workshop or project receiving address to check delivery serviceability. Indus MegaMart accepts orders and payment even if the requested quantity exceeds available stock. Under its ordering policy, delivery is within 7 days for quantities within available stock and within 7–14 days for quantities exceeding stock, including zero stock, subject to serviceability.
Frequently asked questions
1. What is the difference between 751109 and 750109?
Both belong to the PNOZ s9 timing family and use nominal 24 V DC. The 751109 has spring-loaded plug-in terminals and a 100 mm height; 750109 has screw terminals and a 98 mm height. The coated spring-terminal option is 751189. Match the precise order number to your approved design.
2. Can the PNOZ s9 C operate without another safety relay?
Yes, Pilz permits standalone use as a safety timer or pulse relay. Standalone use is single-channel. For contact expansion, select a compatible base relay with feedback-loop monitoring. Do not treat this as a generic dual-channel E-stop monitoring relay.
3. Are all four contacts safety outputs?
No. The three timed NO contacts are safety contacts; the timed NC contact is auxiliary and must not be used as an additional safety contact.
4. Can I use the 300-second setting to verify that a machine has stopped?
No. The timer does not measure speed or standstill. Select a timing function from the risk assessment and validated stopping behaviour; account for the specified tolerance and fault behaviour. Where standstill detection is required, choose suitable monitoring equipment.
5. Which accessories are available from Pilz for the 17.5 mm version?
Pilz lists 751003 as a replacement spring-terminal set and 750020 as a connector pack of ten for joining PNOZsigma base and expansion units. Check the required connector and terminal arrangement and confirm any separately ordered accessories before purchase.
6. Is the quoted price for ten relays?
The manufacturer packaging for order number 751109 contains one relay. The distinct factory ten-piece SKU is 751909. Confirm the seller’s stated selling unit on the exact 751109 product listing before payment.
7. Does Indus MegaMart provide GST invoices?
Purchase invoices contain the company GST number. Review the GST-inclusive price, quantity and final order total on the product listing before proceeding.
Order Pilz 751109 PNOZ s9 C for your Arunachal Pradesh requirement
Confirm the 24 V DC spring-terminal variant, the required timing function and the number of relays. View the current price and delivery details, then purchase the exact part through Indus MegaMart.
Buy Now – Pilz 751109 PNOZ s9 C