Fluke 287/FVF True RMS Logging Multimeter Kit in Andhra Pradesh
Buy the Fluke 287/FVF True RMS Logging Multimeter Kit for electronics troubleshooting, test laboratories and maintenance work in Andhra Pradesh. The kit combines the Fluke 287 (OEM kit part 3340186), onboard TrendCapture recording, FlukeView Forms software and a dedicated set of measurement accessories. It is a practical choice when a single reading is not enough: for example, when a power supply drifts during a test or a circuit fault appears only intermittently.
Review the current price, selling quantity and tax details for the exact kit before placing your order. Confirm delivery serviceability for your Andhra Pradesh pincode and select the quantity required for your lab or maintenance team.
View price and order Fluke 287/FVF
What comes with the Fluke 287/FVF kit?
The manufacturer lists the following components for the Fluke 287/FVF combo kit. Confirm the seller’s supplied pack against this list when ordering; a standalone Fluke 287 is not the same package.
| Component |
Manufacturer kit contents |
|
Instrument |
Fluke 287 electronics logging multimeter |
|
Reporting |
FlukeView Forms software and communication cable |
|
Temperature |
80BK-A Type-K thermocouple |
|
Leads |
Red/black modular test leads, CAT III 1000 V, 10 A |
|
Probes |
Red/black modular probes, CAT II 1000 V, 10 A, with CAT III-rated caps |
|
Clips |
Red/black alligator clips, CAT III 1000 V, 10 A |
|
Accessory set |
TLK287 electronic test lead set |
|
Hands-free |
Magnetic hanging strap |
|
Protection |
C280 soft case |
|
Input protection accessory |
Amp jack plug set |
Fluke 287/FVF technical specifications
|
Measurement or feature |
Specification |
|
Model |
Fluke 287/FVF; OEM part 3340186 |
|
Display |
50,000 counts; backlit quarter-VGA display |
|
AC/DC voltage |
Up to 1000 V; 50 mV to 1000 V ranges |
|
DC voltage accuracy |
0.025% basic; e.g., 5 V and 50 V ranges ±(0.025% of reading + 2 counts) |
|
AC voltage accuracy |
0.4% basic True RMS (range and frequency dependent) |
|
AC/DC direct current |
Up to 10 A; ranges from 500 µA to 10 A |
|
Basic current accuracy |
DC 0.05%; AC 0.6% True RMS; conditions apply |
|
Resistance / conductance |
Up to 500 MΩ; 50 nS range |
|
Capacitance |
Up to 100 mF |
|
Frequency counter |
Up to 999.99 kHz; input sensitivity and bandwidth limits apply |
|
AC measurement bandwidth |
Up to 100 kHz on specified ranges, not all voltage/current ranges |
|
Temperature |
Meter −200 to 1350 °C excluding probe; supplied 80BK-A −40 to 260 °C |
|
Other functions |
Continuity, diode test, duty cycle, pulse width, dBV/dBm, REL, hold, Min/Max/Avg |
|
Logging |
Interval and event recording; TrendCapture; multiple sessions |
|
Meter safety rating |
CAT III 1000 V / CAT IV 600 V; IEC 61010-2-033 |
|
Power |
6 AA alkaline batteries; OEM specifies minimum 100 h, 200 h in logging mode |
|
Operating / storage |
−20 to 55 °C / −40 to 60 °C; observe specified humidity limits |
|
Humidity |
Up to 90% at 0–37 °C; 65% at 37–45 °C; 45% at 45–55 °C |
|
Meter size / weight |
222 × 102 × 60 mm; approximately 871 g (meter, not packed kit) |
The figures above describe the meter, not every accessory or measurement condition. Accuracy depends on the selected range, signal frequency, crest factor and environment. The manual specifies 20 A for a maximum of 30 seconds followed by 10 minutes off; accuracy above 10 A is not specified. For routine direct-current measurement, remain within the applicable 10 A or lower input rating.
Capture intermittent faults and document readings
TrendCapture is useful when a bench technician needs to see how a reading changes during a test without remaining at the display. Set an interval and an event threshold appropriate for the measurement, then review the recorded trend on the backlit screen. The meter supports multiple saved sessions and trend zoom up to 14x.
Sample intervals and event records share available memory: up to 10,000 sample intervals can be recorded, and the maximum event count is 15,000 minus the number of sample intervals. Existing saved data reduce the available capacity. Logging time depends on memory, settings and battery condition. Save the recording before closing the session.
For fast peaks the specified response is 250 µs for repetitive peaks and 2.5 ms for single events, subject to the function and range. Peak capture is distinct from interval logging and does not provide a continuous oscilloscope waveform.
From meter readings to a test report
Review the trend on the instrument first, then use the supplied interface cable and FlukeView Forms to transfer recorded measurements to a compatible PC. Arrange test readings into tables or graphs for design validation, maintenance records or investigation of an intermittent fault. Fluke’s 3.8 update documents Windows 10 support. Confirm software licence, version, drivers and your company’s IT requirements before relying on a new installation.
When to choose this kit instead of another multimeter
For electronics development, repair and production test, the 287/FVF is intended for precise DC readings, True RMS AC measurement, extended component ranges and record-based diagnostics. The base Fluke 287 offers the meter’s logging capability; choose the FVF kit if the software, connection cable and additional test accessories are needed together. The Fluke 289 is a separate industrial logging model with dedicated low-pass filtering for drive-output measurements. The 287’s selectable smoothing function is not that dedicated VFD low-pass filter.
The meter is rated CAT III 1000 V and CAT IV 600 V, but the lowest rating of the meter, leads, probes, clips and configuration determines the safe measurement setup. Follow the manual, verify the meter on a known voltage and use correctly rated accessories. The manufacturer classifies this as Class A EMC equipment, not intended for residential environments. Do not use the kit as a substitute for a dedicated insulation tester or high-current clamp meter.
Compare other Fluke instruments or review test and measurement instruments for different measurement requirements.
Ordering and delivery for Andhra Pradesh buyers
Indus MegaMart accepts orders and payment even if stock is insufficient. For a serviceable Andhra Pradesh delivery address, quantities within available stock are covered by the delivery policy of delivery within 7 days. Quantities exceeding available stock, including zero stock, follow the 7–14 days delivery policy. Confirm your pincode, selling quantity and current order details before payment. Purchase invoices contain the company’s GST number.
Frequently asked questions
1. Can the Fluke 287/FVF log two independent functions simultaneously?
No. It records the selected measurement function; for example, resistance and temperature cannot be independently logged at the same time. Use separate suitable instruments if you require concurrent independent channels.
2. Does the kit include everything needed for Fluke Connect wireless communication?
No. The FlukeView Forms software and cable are included in the OEM kit, but the optional ir3000 FC infrared connector is not. Check current app and connector compatibility before purchasing wireless accessories.
3. Can I use the supplied thermocouple up to 1350 °C?
No. The included 80BK-A is specified for −40 to 260 °C. The wider meter input range requires a suitable compatible probe; the probe’s own limitations apply.
4. Is the 287/FVF a substitute for an oscilloscope?
No. TrendCapture shows trends from recorded readings, not a full high-speed waveform. For detailed waveform shape or very brief single events, select a suitable oscilloscope.
5. Will FlukeView Forms work on Windows 11?
Fluke documents Windows 10 compatibility for the 3.8 software update. Confirm supported software versions, drivers and activation on your intended Windows 11 system before purchase.
6. What should purchasing teams confirm about the kit before ordering?
Match Fluke 287/FVF and OEM part 3340186, confirm seller pack quantity and included accessories, and review the current price, tax treatment and applicable warranty/return terms on the product listing or with the seller.
7. Can I order for Andhra Pradesh if stock is insufficient?
Yes. Indus MegaMart accepts orders and payment even when available stock is zero. Quantity above available stock follows the 7–14 day delivery policy, subject to serviceability of the delivery pincode.
Choose the complete logging and reporting kit for your electronics testing requirements in Andhra Pradesh.
Buy Fluke 287/FVF True RMS Logging Multimeter Kit