Fluke 28 II Ex Intrinsically Safe Digital Multimeter in Allahabad
Order the Fluke 28 II Ex Intrinsically Safe Digital Multimeter from Indus MegaMart for electrical maintenance procurement in Allahabad. This handheld True RMS meter is intended for work in specified classified gas areas as well as ordinary locations. It combines high-resolution measurement, a rugged IP67-rated enclosure and diagnostic functions for maintenance teams working with industrial electrical and instrumentation systems. The Ex version is distinct from the ordinary Fluke 28 II; verify the precise approval marking and circuit limits before selecting it.
Review the current product price, tax basis, selling quantity and delivery details for your Allahabad delivery address on the product listing. For a site purchase order, confirm the required Ex approval variant and any calibration documentation before payment.
View price and buy Fluke 28 II Ex
Intrinsic safety: select the correct approval and circuit limits
Fluke lists IECEx Ex ia IIC T4 Gb and ATEX II 2G Ex ia IIC T4 Gb gas markings, plus mining markings Ex ia I Ma / I M1 Ex ia I Ma. These are model-family approvals, not a blanket authorisation for any explosive atmosphere. The gas marking relates to Zones 1 and 2; match the actual unit’s label, certificate, local regulatory acceptance, gas group, temperature class, ambient conditions and site risk assessment. North American approval variants are also listed by Fluke; confirm the required version before purchase.
The ordinary-location 1000 V and 10 A measurement ranges do not apply as permissible Ex inputs. Ecom specifies Ui ≤ 65 V and Ii ≤ 5 A inside hazardous areas for the relevant connections; terminal-specific limits and entity parameters may be more restrictive. Only qualified personnel should use the meter under the supplied ECOM safety instructions and site procedures. Do not open it or change batteries or fuses in a hazardous area. Verify the exact serial number against Fluke’s recall notice before use, and do not use a recalled or damaged unit.
Fluke 28 II Ex technical specifications
|
Parameter |
Specification |
|
Model / response |
28 II Ex; True RMS AC voltage and current |
|
Ordinary-location AC/DC voltage |
Up to 1000 V; 0.1 mV minimum resolution |
|
Ordinary-location AC/DC current |
Up to 10 A; 0.1 µA minimum resolution; temperature-dependent duty limits |
|
Ex connection limits |
Ui ≤ 65 V; Ii ≤ 5 A on applicable A input; other entity and terminal limits apply |
|
Electrical measurement category |
CAT III 1000 V / CAT IV 600 V; not Ex connection permission |
|
Resistance / conductance |
Up to 50 MΩ / 60 nS |
|
Capacitance / diode |
Up to 9999 µF / 2 V diode test; continuity |
|
Frequency / duty cycle |
0.5 Hz–199.99 kHz / 0–99.9% (function-dependent) |
|
Temperature |
−200°C to +1090°C meter range; suitable type-K probe required |
|
Display / recording |
6000 counts; 19,999 in high-resolution mode; Min/Max/Avg and 250 µs peak capture |
|
Basic DC voltage accuracy |
±(0.05% of reading + 1 digit), subject to range and conditions |
|
Enclosure / impact |
IP67 when non-operating; 3 m drop rating with holster |
|
Power |
3 type-approved AAA cells; typical 400 hours without backlight |
|
Size / weight with holster |
About 6.4 × 10.0 × 19.8 cm (H × W × L); about 700 g |
Measurement ranges are instrument capabilities, not permission to test any energized circuit. For ordinary-location current measurement, 10 A continuous is specified up to 35°C; above that temperature the manual requires shorter measurement periods and rest intervals. Consult the range-specific accuracy tables and safety instructions for all conditions.
Where the 28 II Ex fits in maintenance work
For petroleum, chemical and pharmaceutical operations, the Ex designation matters when an instrument must enter a classified area. For example, instrumentation teams can select the meter for approved low-energy circuit checks, while electrical maintenance staff may use the same instrument in ordinary locations for compatible voltage, current and component diagnostics. Suitability is determined by site classification and circuit parameters, not the industry name alone.
True RMS measurement helps evaluate non-sinusoidal AC signals. The low-pass filter can help characterize variable-speed drive signals where permitted; never use filtered readings to establish the absence of hazardous voltage. Min/Max/Average and peak capture assist with intermittent changes, while relative mode helps compensate for lead resistance. Auto/manual ranging, illuminated controls and a dual-level backlight support work in poor lighting. The Input Alert assists with incorrect lead placement but does not replace safe work practices.
Box contents and equipment selection
Fluke’s standard configuration lists one 28 II Ex meter, Ex holster, one pair of test leads, one pair of alligator clips, installed batteries and a quick reference guide. Confirm the merchant’s actual selling unit, included safety instructions, leads and approval variant before ordering. Optional accessories include a suitable type-K temperature probe; Fluke lists TL175 leads, AC172/AC175 clips and i400 clamp among related accessories. Use accessories in Ex areas only if the complete configuration is explicitly permitted; the magnetic hanger is for use outside Ex areas.
Fluke describes a three-year limited manufacturer warranty, subject to its published exclusions and terms. Confirm the warranty route, calibration certificate availability and returns conditions for the actual item before finalizing a procurement order. For other measurement tasks, browse Fluke instruments or compare digital multimeters within test and measurement instruments.
Ordering and delivery in Allahabad
Select the required quantity and confirm serviceability for your Allahabad delivery pincode before completing payment. Under Indus MegaMart’s ordering policy, orders within available stock qualify for delivery within 7 days; orders above available stock, including zero stock, can still be placed and paid for, with delivery within 7–14 days. This is a stock-based policy, not a statement that the meter is stocked in Allahabad. Confirm your site’s approval and documentation needs when arranging the purchase.
Frequently asked questions
1. Is the 28 II Ex suitable for Zone 0 or dust Zone 21/22?
Do not assume so. The current manufacturer documentation identifies gas Zones 1 and 2 under the Ex ia IIC T4 Gb marking. Dust-zone or Zone 0 use requires explicit applicable certification on the actual unit and site approval; do not rely on older listings.
2. Can it measure 1000 V inside a hazardous area?
No. The ordinary-location range is not the Ex rating. Ecom lists a maximum input voltage Ui of 65 V and current Ii of 5 A for the applicable high-current connection in Ex areas. All terminal-specific entity limits and the site safety procedure must also be satisfied.
3. Does the 28 II Ex measure distorted AC waveforms?
Yes. True RMS AC measurement is useful on non-sinusoidal signals within the meter’s specified range, bandwidth and crest-factor limits.
4. Is the temperature probe included?
The manufacturer lists the meter, Ex holster, test leads, alligator clips, installed batteries and quick reference guide. A compatible type-K temperature probe is an optional accessory; confirm the supplied configuration before ordering.
5. Can batteries or fuses be replaced in an Ex area?
No. Service and battery or fuse replacement must take place outside hazardous areas, using the specified Ex-approved components and the manufacturer’s instructions.
6. Is the 28 II Ex the same as the ordinary Fluke 28 II?
No. The Ex version is intended for specified classified environments and has separate approval conditions. Do not substitute an ordinary 28 II solely because its electrical ranges or enclosure rating look similar.
7. How do I check recall status?
Check the actual part number and serial number against Fluke’s recall notice. If the unit is affected or cannot be identified as instructed by Fluke, do not use it; follow the manufacturer’s recall procedure.
8. Can I order more units than are currently available?
Yes. Indus MegaMart accepts orders and payment even when requested quantity exceeds available stock, including zero stock. The applicable delivery window is 7–14 days for those orders.
9. Does Indus MegaMart provide a GST invoice?
Generated purchase invoices contain Indus MegaMart’s GST number. Confirm the applicable tax and order total on the exact product page before payment.
Buy the Fluke 28 II Ex from Indus MegaMart