Buy Fluke 175 True RMS Digital Multimeter in Aligarh
The Fluke 175 True RMS Digital Multimeter is a handheld electrical test instrument for maintenance engineers, electricians and industrial service teams. It combines accurate AC voltage and current readings within its specified True RMS limits with DC measurements, resistance, capacitance, frequency, continuity and diode testing. Its CAT III 1000 V and CAT IV 600 V ratings make it a useful option for trained technicians selecting a meter for appropriate distribution circuits and equipment checks.
For a Aligarh purchase, check the GST-inclusive price on Indus MegaMart’s Fluke 175 listing, select the required quantity and enter your delivery pincode to review serviceability. Confirm the selling quantity and any required calibration documentation before checkout.
Buy Now – Fluke 175 True RMS Digital Multimeter
Fluke 175 measurement specifications
|
Measurement/attribute |
Range or value |
Accuracy / detail |
|
AC voltage (true RMS) |
1000 V; 0.1 mV best resolution |
±(1.0% + 3) at 45–500 Hz; ±(2.0% + 3) at 500 Hz–1 kHz |
|
DC voltage |
1000 V; 0.1 mV best resolution |
±(0.15% + 2) |
|
AC current (true RMS) |
10 A; 0.01 mA best resolution |
±(1.5% + 3), 45 Hz–1 kHz |
|
DC current |
10 A; 0.01 mA best resolution |
±(1.0% + 3) |
|
Resistance |
50 MΩ; 0.1 Ω best resolution |
Best ±(0.9% + 1); highest range ±(1.5% + 3) |
|
Capacitance |
9999 µF (nominal 10,000 µF); 1 nF best resolution |
Best ±(1.2% + 2); highest range 10% typical above 1000 µF |
|
Frequency |
2 Hz–99.99 kHz on V input; 2 Hz–30 kHz on A input |
±(0.1% + 1); 0.01 Hz best resolution |
|
Continuity/diode |
Audible continuity; diode test up to 2.400 V |
Continuity sounds below 25 Ω; off above 250 Ω; diode ±(1% + 2) |
|
Display and safety |
6000 counts; analogue bar graph |
CAT III 1000 V / CAT IV 600 V |
|
Size/weight |
43 × 90 × 185 mm; 420 g |
Integrated protective holster |
|
Environment |
Operating −10 °C to +50 °C; storage −30 °C to +60 °C |
Non-condensing RH up to 90% at 0–35 °C, 70% at 35–50 °C |
|
Power |
9 V battery |
Alkaline, about 200 hours typical |
Accuracy values are expressed as ±(percentage of reading + display counts). Best resolution is achieved on the relevant lower range, not at every measurement level. The AC ranges are specified from 5% to 100% of range; crest factor and non-sinusoidal waveform conditions also apply. Refer to the Fluke manual for the range-specific tolerances and input restrictions.
Features that help with maintenance measurements
Use automatic or manual range selection depending on the task. The 6000-count display and analogue bar graph help technicians observe changes while the numeric reading provides the measured value. Display Hold retains a reading; Auto Hold captures a new stable reading. MIN MAX AVG recording helps identify changes during a measurement session, but is not a substitute for high-speed transient capture or a logging instrument.
The integrated protective holster and battery access support field handling. The meter also supports closed-case calibration through the front panel. Calibration capability does not mean a traceable calibration certificate is supplied with every order.
Applications and electrical safety limits
The 175 is useful for checking supply voltage at suitable control panels, power-supply circuits and distribution equipment, validating DC control voltages and troubleshooting de-energised wiring or components with resistance, continuity and capacitance functions. True RMS AC measurement is particularly relevant when the waveform is not a simple sine wave, provided it remains within the instrument’s specified limits.
Match the measurement category and voltage to the installation: CAT III 1000 V is not CAT IV 1000 V. The complete measurement setup must meet the applicable category, including the leads and probes. Use the correct fused input for current measurement and stay within the specified 10 A maximum; for higher current or non-intrusive measurements consider a suitably rated clamp meter. Never use resistance, continuity, diode or capacitance functions on energised circuits. Do not assume the 175 can accurately measure every PWM drive output; select a drive-appropriate instrument when required. Follow the manufacturer’s manual and site electrical safety procedures.
Choosing the 175 instead of the 177 or 179
All three 170 Series models offer True RMS AC measurement. The 175 does not have a backlight or contact temperature function. The 177 and 179 add a backlight and improve basic DC accuracy on lower voltage ranges to ±(0.09% + 2); the 179 additionally includes temperature measurement. Select the 175 when everyday electrical readings and the stated safety categories meet the job, rather than buying it for temperature measurement or a backlit display.
Explore other digital multimeters
Standard Fluke kit and procurement checks
Fluke describes the standard 175 kit as the meter, a pair of test leads, an installed 9 V battery and documentation (quick reference guide/user manual). The manufacturer’s kit contents do not establish a retailer’s pack configuration. Confirm the listed selling unit, any optional leads or carrying case, and calibration or warranty requirements when placing the order.
Browse Fluke test instruments
Ordering and delivery in Aligarh
Indus MegaMart supplies test and measurement instruments to Aligarh buyers. For workshop replenishment, contractor kits or facility maintenance procurement, choose the required number of meters and check the destination pincode. Purchase invoices contain the company’s GST number. For bulk requirements, documentation and commercial terms, use the product page or contact the supplier before submitting the purchase order.
The Indus MegaMart ordering policy allows customers to order and complete payment even when available stock is insufficient. If the order quantity is within available stock, delivery is within 7 days. For quantities exceeding available stock, or when stock is zero, delivery is within 7–14 days. Check your delivery details for the chosen destination.
Frequently asked questions
1. Can the Fluke 175 measure temperature?
No. The operating temperature range describes the meter’s environment, not an enabled thermometer function. Select the Fluke 179 if contact temperature is a required measurement.
2. Is the 175 a True RMS meter for both AC voltage and AC current?
Yes. True RMS processing supports AC voltage and current measurements within the specified range, bandwidth and waveform limits. It does not automatically make every drive output suitable for measurement.
3. Can I measure 1000 V in a CAT IV environment?
No. The Fluke 175 is rated CAT IV 600 V and CAT III 1000 V. Use appropriately rated leads and equipment and follow the applicable electrical safety procedures.
4. What frequency range can this meter measure?
Fluke specifies 2 Hz to 99.99 kHz through the voltage input and 2 Hz to 30 kHz through the current input. These are frequency measurement limits, not the AC voltage accuracy bandwidth.
5. Does the Fluke 175 include a calibration certificate?
The standard kit is not evidence of an accredited calibration certificate. If your purchase specification requires a certificate, confirm the calibration service, scope and paperwork before ordering.
6. What warranty applies to the Fluke 175?
Fluke lists a limited lifetime warranty for the meter, subject to its terms and eligibility. Confirm the applicable seller-backed warranty, proof of purchase and service process with Indus MegaMart before purchase.
7. Can I buy several Fluke 175 meters for a Aligarh maintenance team?
Yes. Select the required order quantity on the product page; for procurement documentation or larger requirements, contact Indus MegaMart. Orders and payment are accepted even when the requested quantity exceeds available stock.
8. How do I check the Fluke 175 price and delivery for my Aligarh address?
Open the exact product listing for the GST-inclusive price and enter the delivery pincode. Under Indus MegaMart’s ordering policy, orders within available stock are delivered within 7 days; orders above available stock, including zero-stock orders, follow a 7–14 day timeline.
Order Fluke 175 True RMS Digital Multimeter from Indus MegaMart