Fluke 362 200A AC/DC Clamp Meter in Ahmedabad
For electrical maintenance teams in Ahmedabad that need both alternating and direct current measurements, the Fluke 362 offers a compact 200 A AC/DC clamp with an 18 mm triangular jaw. It is a practical choice for smaller conductors in distribution panels, UPS systems and battery equipment. It also measures AC and DC voltage up to 600 V through test leads, with resistance and continuity functions for basic electrical diagnostics. The instrument is rated CAT III 600 V.
Order the exact Fluke 362 from Indus MegaMart. Review the current GST-inclusive price, select the required quantity and check delivery for your Ahmedabad pincode on the product listing. For team purchases, confirm the selling unit, included accessories, warranty terms and calibration documentation before placing the order.
View current price and buy Fluke 362
Fluke 362 specifications: current, voltage and physical fit
|
Measurement / attribute |
Range / resolution |
Accuracy / condition |
|
AC current (jaw) |
200.0 A; 0.1 A |
±(2% + 5 digits), 45–65 Hz; ±(2.5% + 5 digits), 65–400 Hz |
|
DC current (jaw) |
200.0 A; 0.1 A |
±(2% + 5 digits) |
|
AC voltage (leads) |
600.0 V; 0.1 V |
±(1.5% + 5 digits), 45–400 Hz |
|
DC voltage (leads) |
600.0 V; 0.1 V |
±(1% + 5 digits) |
|
Resistance (leads) |
300 Ω / 3,000 Ω; 0.1 Ω / 1 Ω |
±(1% + 5 digits) |
|
Continuity |
Beeper at ≤ 70 Ω |
De-energized circuit only |
|
Jaw and body |
18 mm; 205 × 60 × 22 mm |
196 g; fixed triangular jaw |
|
Electrical safety |
CAT III 600 V |
IEC/EN 61010-1 and 61010-2-032 |
|
Environment |
0–40 °C; up to 2,000 m |
IP30 case; non-condensing; no water protection |
|
Power and controls |
2 AAA; HOLD; DC ZERO |
Backlit display; auto power-off after 15 min |
The accuracy figures above are expressed as a percentage of the reading plus display digits. Fluke specifies an additional temperature coefficient of 0.1 times the specified accuracy for each degree above 28 °C or below 18 °C. Operate within 0–40 °C and non-condensing conditions (up to 90% relative humidity from 10–30 °C and 75% from 30–40 °C). The enclosure has no rated water protection; do not use it in damp or wet conditions.
Current checks in narrow panels and DC power systems
The fixed triangular jaws fit around a single accessible conductor without opening the circuit. Verify that the outside diameter of the insulated cable fits within the 18 mm opening and that the jaws close fully. Clamping around the outgoing and returning conductors together can cancel the magnetic fields and produce a misleading load-current reading. A qualified technician should follow the meter manual and site electrical-safety procedures.
For DC current, zero the display before taking the measurement in accordance with the manual; the ZERO control helps remove the initial offset. HOLD retains a reading when the viewing angle is awkward. The compact body is useful when working in restricted spaces, but it does not remove electrical hazards or make otherwise inaccessible live equipment safe.
Where the 362 fits
UPS and inverter servicing: compare normal load current on suitable AC circuits and DC battery conductors. Battery chargers and battery banks: check charge or discharge current within the 200 A limit; the meter does not establish battery capacity or state of health by itself. Commercial facility maintenance: compare the current draw of individual feeders or small motors to expected running values. Electrical troubleshooting: use suitably rated leads for voltage and de-energized resistance and continuity checks.
When a different clamp meter is needed
Choose another model if the expected current exceeds 200 A, the conductor cannot fit the 18 mm opening, or the installation requires a higher measurement category than CAT III 600 V. The 362 is not specified as a True-RMS, inrush-current or dedicated leakage-current instrument; select a suitably specified meter for distorted waveforms, motor starting peaks or small leakage measurements. It does not provide a dedicated frequency, capacitance or temperature function. AC measurement frequency limits are not a frequency-measurement mode. Never exceed the current, voltage or category rating, including the rating of the lowest-rated component in the measurement setup.
Compare other clamp meters
Explore Fluke test instruments
Package, documentation and ordering in Ahmedabad
Fluke’s documented standard package consists of the 362 clamp meter, a TL75 test-lead set, two installed AAA batteries and a user manual. Fluke lists a two-year limited manufacturer warranty; exclusions apply. Its India technical brochure also describes a calibration certificate. Confirm the certificate, actual supplied accessories and warranty eligibility for the particular unit with Indus MegaMart, especially when procurement requires traceable calibration or a specific document format.
For a maintenance department, contractor or facility in Ahmedabad, use the exact product listing to confirm the quantity, selling unit and GST-inclusive price before completing the purchase. Indus MegaMart purchase invoices include the company’s GST number. Orders and payments are accepted even if available stock is zero or lower than the requested quantity. Under the standard delivery policy, quantities within available stock are delivered within 7 days; orders exceeding stock, including zero-stock orders, are delivered within 7–14 days. Check the delivery details for your Ahmedabad pincode before ordering.
Browse test and measurement instruments
Frequently asked questions
1. Can the Fluke 362 measure DC current in a UPS battery cable?
Yes. The clamp measures direct current up to 200 A as well as AC current up to 200 A. The conductor must fit the 18 mm jaw, and the circuit and meter must remain within the rated electrical limits.
2. Is the Fluke 362 a 400 A or 600 A clamp meter?
No. Both AC and DC clamp current are limited to 200 A. The 600 V figure describes the voltage measurement range and CAT III voltage rating, not the current range.
3. Does the Fluke 362 have a detachable jaw?
No. It has a fixed triangular clamp with an 18 mm opening. Check the conductor diameter and access clearance before buying.
4. Is this model suitable for checking small leakage currents or motor inrush?
The 0.1 A current resolution and published functions are intended for basic load-current checks. Dedicated leakage and inrush measurement functions are not specified for the 362.
5. Can resistance and continuity be tested with the clamp jaws?
No. These tests use the test leads with the circuit de-energized. The resistance ranges are 300 Ω and 3,000 Ω; the continuity buzzer activates at 70 Ω or below.
6. Are test leads and a calibration certificate supplied with the Fluke 362?
Fluke documents TL75 test leads in the standard package and an India calibration certificate in its technical brochure. Confirm the exact contents, certificate and warranty for the unit being ordered.
7. How can I check the Fluke 362 price and delivery to Ahmedabad?
Open the exact product listing, review the current GST-inclusive price and quantity, and use the delivery check with your destination pincode. The order quantity relative to available stock determines the standard delivery window.
8. Can a purchasing team order more units than the displayed stock?
Yes. Indus MegaMart accepts orders and payment even above available stock. The standard delivery window for excess or zero-stock orders is 7–14 days; confirm the required quantity and delivery details at purchase.
Buy Fluke 362 200A AC/DC Clamp Meter – check price and order for Ahmedabad